Preferred Language
Articles
/
jih-947
Determination of Adenosine Deaminase Activity in type 1 and type 2 Diabetes Mellitus
...Show More Authors

         Serum adenosine deaminase (ADA) activity was determined in 30 blood sample of type 1 diabetic individuals 30 blood sample for the type 2 and 15 normal children as a control for type 1 15 normal adults as control for type 2. The mean ADA activity and specific activity in type 1 was (8.85± 5.55 U/mg of protein) which is compared with control (32.11± 1.54 U/mg of protein) while in type 2 was (48.46±11.91 U/mg of protein) is compared with control (5.18± 2.27 U/mg of protein ). We conclude that the altered blood level of ADA activity may help in predicting immunological dysfunction in diabetic individuals and also has a prognostic value.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Different Methods of Canine Retraction- Part 1
...Show More Authors

Background: This review aimed at explaining different methods of canine retraction along the archwire. Methods: Searching for different methods of canine retraction using fixed orthodontic appliances was carried out using different databases, including PubMed Central, Science Direct, Wiley Online Library, the Cochrane Library, Textbooks, Google Scholar, Research Gate, and hand searching from 1930 till February 2022. Results: After excluding the duplicate articles, papers describing the methods of canine retraction along the archwires were included. The most commonly used methods are NiTi closed coil spring and elastic chain. Conclusions: Various methods of canine retraction along the archwires were explained in detail regarding their adv

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Wed Nov 02 2016
Journal Name
Australian Journal Of Basic And Applied Sciences
Full synchronization of 2$\times$ 2 optocouplers network using LEDs
...Show More Authors

The synchronization of a complex network with optoelectronic feedback has been introduced theoretically, with use of 2×2 oscillators network; each oscillator considered is an optocoupler (LED coupled with photo-detector). Fixing the bias current (δ) and increasing the feedback strength (Ԑ) of each oscillator, the dynamical sequence like chaotic and periodic mixed mode oscillations has been observed. Synchronization of unidirectionally coupled of light emitting diodes network has been featured when coupling strength equal to 1.7×10-4. The transition between non-synchronization and synchronization states by means of the spatio-temporal distribution has been investigated.

Publication Date
Sat Nov 30 2024
Journal Name
Iraqi Journal Of Science
Evaluation of Syndecan-1 Expression in Iraqi Patients with Papillary Thyroid Carcinoma
...Show More Authors

Papillary thyroid carcinoma (PTC) represents the most prevalent kind of thyroid gland cancer, making up around 80% of all occurrences of thyroid cancer. Evidence shows that Syndecan-1 (SDC-1) expression is lost in a number of benign and malignant epithelial neoplasms, although its expression profile in thyroid gland neoplasms is yet unknown. Therefore, the aim of this study was to assess SDC-1 expression in papillary thyroid carcinoma patients, as well as the relationship between age and gender and SDC-1 expression. To undertake a detailed investigation of SDC-1 in normal and malignant tissues, tissue sections were used to examine SDC-1 expression in 70 tissue samples, 50 distinct PTC (6 males and 44 females) and 20 normal tissue ty

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Determination of some heavy Metals in tattoo Stickers in Children sweets available in local markets: Determination of some heavy Metals in tattoo Stickers in Children sweets available in local markets
...Show More Authors

The objective of this study is to determination the content of some heavy metals (lead, cadmium, chromium) in colored tattoo stickers. twelve kinds of colored tattoo stikcers were collected from Baghdad markets, it was estimated heavy metals using atomic absorption spectrophotometer (Shimadzu A5000). The results indicated the concentrations of lead in all samples (1.61_1.00 mg / kg) and chromium in the three samples (0.85_0.97 mg / kg) while other samples are free of chromium , and cadmium. These elements are the components of printing inks and dyes in tattoo stickers, and this does not conform to the health and safety conditions for the packaging of food according to the organizations of the health and safety of

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Evaluation of the Expression of RCC and KIM-1 Biomarkers in Nephrotoxicity of Rabbits Treated with Ochratoxins A
...Show More Authors

View Publication
Clarivate Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
Rapid Spectrophotometric Determination of Phenoxazine
...Show More Authors

A rapid high sensitive and inexpensive economic method has been developed for the Determination of phenoxazine by using molecular spectrophotometry. The method is based on the oxidation of phenoxazine by potassium (meta)periodate in acidic medium. The oxidation conditions were selected to enhance the sensitivity and the stability of the pink colored species which shows an absorption maximum at 530 nm. The Beer’s law was obeyed for phenoxazine concentration range from 1 to 6 µg mL-1 with 0.003 µg mL-1 detection limit and provided variation coefficients between 0.4 to 1.7 %. This method was successfully applied for the determination of phenoxazine in aqueous samples

View Publication Preview PDF
Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Potentiometric Determination of Iodide in Magnesium Fluoride by Iodide Electrode
...Show More Authors

Iodide Ø¢ in samples Ø¢ containing Ø¢ magnesium Ø¢ fluoride Ø¢ was Ø¢ determinedØ¢  Ø¢ by using iodide selective Ø¢ electrode. Ø¢ Detecting Ø¢ the limit for iodide determination

was around Ø¢ 5x1 oآ·5Ø¢ Ø¢ M with a standard Ø¢ deviation Ø¢ ranged Ø¢ from Ø¢ Ø¢Â± 0.3 to آ± 0.6.

QuantitativeØ¢  Ø¢ methodsØ¢  Ø¢ including; standard Ø¢ additionØ¢  Ø¢ method, Ø¢ Potentiometric

titration Ø¢ by using a Gran plot paper for an equivalent Ø¢ point determination and a Ø¢ directØ¢  Ø¢ methodØ¢&n

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption
...Show More Authors

This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.

In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Spectrofluorimetric method for the determination of glibenclamide in pharmaceutical formulations
...Show More Authors

A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Partial Differential Equations In Applied Mathematics
Determination of time-dependent coefficient in time fractional heat equation
...Show More Authors

View Publication
Scopus (13)
Crossref (3)
Scopus Crossref