Preferred Language
Articles
/
jih-913
Spectrophotometric Determination of Isoptin (Verapamil Hydrochloride) in Pharmaceutical Preparations
...Show More Authors

Verapamil Hydrochloride (VH) has been determined spectrophotometrically by using Methyl Orange (MO).  In our previous researches MO was used for determination of Mexiletine Hydrochloride [1]. The method was based on complexation between (MO and VH).  After shaking and diluting the complex solution with D.W, the pH was adjusted with NaOH and HCl to pH 4. The colored complex formed between VH and the reagents were transferred into separating funnels and extracted using 4.5 ml CH2Cl2 and were shaken for (4 minutes).  The extracted organic layer was used for the preparation of the calibration curves for spectrophotometric measurements of VH at 437nm.  The blanks were carried out in exactly the same way throughout the whole procedure.  Molar absorptivity (ε L.mol-1.cm-1), detection limit, limit of linearity (µg.ml-1) and r2 were, 1.75*105, 0.009253, 0.08 and 0.993 for (VH-MO) respectively. The method was used with reasonable accuracy and precision for the determination of (VH) in synthetic samples of tablets, capsules and ampoules.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Determination of Mefenamic Acid Using a New Mode of Irradiation (Array of Six Identical LEDs) and Detection( Twin Solar Cells) Through Turbidity Measurement by CFIA
...Show More Authors

A newly developed analytical method characterized by its speed and sensitivity for the determination of mefenamic acid (MFA) in pure and pharmaceutical preparation is established via turbidimetric measurement (0-180o) by Ayah 6SX1-ST-2D Solar cell CFI Analyser . The method was based on the reaction of
phosphomolybdic acid with mefenamic acid in aqueous medium to form blue color precipitate as an ion-pair complex . Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o . The chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.3-7 or 0.3-10 mMol.L-1, with correlation coefficient r = 0.9907 or 0.9556 respectively

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
CFIA-Turbidimetric and Photometric Determination of Vitamin B9 (Folic acid) Using LEDs as a Source of Irradiation and Two Solar Cells as an Energy Transducer
...Show More Authors

A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Analytica Chimica Acta
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column

... Show More
View Publication
Scopus (30)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Sun Nov 25 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Study the Shapes of Nuclei for Heavy Elements with Mass Number Equal to (226≤A≤252) through Determination of Deformation Parameters for Two Elements (U&Cf)
...Show More Authors

   The current paper focuses on the studying the forms of (even-even) nuclei for the heavy elements with mass numbers in the range from (A=226 - 252) for  isotopes. This work will consist of studying deformation parameters  which is deduced from the "Reduced Electric Transition Probability" which is in its turn dependent on the first Excited State . The "Intrinsic Electric Quadrupole Moments" (non-spherical charge distribution)  were also calculated. In addition to that the Roots Mean Square Radii (Isotope Shift) are accounted for in order to compare them with the theoretical results.

The difference and variation in shapes of nuclei for the selected isotopes were detected using &

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
New Mode of On- Line Automation: Chemilumino-Fluoro Metric Method for the Determination of Hydrogen Peroxide by Fluorescence Energy Transfer Using Ploy Acrylic Acid Gel Beads
...Show More Authors

Hydrogen peroxide was determined by a new , accurate , sensitive and rapid method via continuous mode of FIA coupled with total luminescence measurement which include the chemiluminescence generated ,based on the oxidation of Luminol which is loaded on poly acrylic acid gel beads by hydrogen peroxide in presence of Cobalt (II) ion as a chemiluminescence catalyst and the fluorescence that was created by the insitu radiation of the released chemiluminescence light. Fluorescien molecule was used as an accepter fluorophore where it is irradiated internally and instantly by the generation of luminol chemiluminescence light as internal source for irradiation of fluorescien molecule (Fluorescence Energy Transfer (FRET) ) . It can easily give fl

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE PHYSICAL AND CHEMICAL PROPERTIES AND DETERMINATION THE CYTOTOXICITY OF KOJIC ACID PRODUCED FROM THE LOCAL ISOLATE ASPERGILLUS FLAVUS WJF81 AND THEIR EFFECTS ON CONSUMER HEALTH.: STUDY THE PHYSICAL AND CHEMICAL PROPERTIES AND DETERMINATION THE CYTOTOXICITY OF KOJIC ACID PRODUCED FROM THE LOCAL ISOLATE ASPERGILLUS FLAVUS WJF81 AND THEIR EFFECTS ON CONSUMER HEALTH.
...Show More Authors

Steps were taken to obtain the Kojic acid crystals from local fungal isolation A. flavus WJF81 by separating the fermentation products from the fungus mycelium from the production plant at the centrifuge at a speed of 5000 cycles for 10 minutes. The extraction was followed by ethyl acetate then supernatant concentrate by using rotary evaporator, and dried with heat oven 37ºC. Long, yellowish, pristine acid crystals were obtained that examined the optical microscope with a magnification force of 10x and 40x. The melting point of kojic acid was determined between 152.9-153.5 °C Results of the diagnosis of Kojic acid by applying High pressure liquid chromatography HPLC technique showed that the acid was at one peak, which was close to the

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (2)
Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Determination of the Elastic and Viscous Behavior of Polycarbonate Melts at Different Temperatures and Their Relationship to the Steady State Viscosity via the Cox-Merz Rule
...Show More Authors

Rheological instrument is one of the basic analytical measurements for diagnosing the properties of polymers fluids to be used in any industry. In this research polycarbonate was chosen because of its importance in many areas and possesses several distinct properties.
Two kinds of rheometers devices were used at different range of temperatures from 220 ˚C-300 ˚C to characterize the rheological technique of melted polycarbonate (Makrolon 2805) by a combination of different investigating techniques. We compared the results of the linear (oscillatory) method with the non-linear (steady-state) method; the former method provided the storage and the loss modulus of melted polycarbonate, and presented the Cox-Merz model as well. One of the

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 12 2025
Journal Name
Tikrit Journal Of Administrative And Economic sciences
Determination of competency levels and auditor evaluation procedures to the international standard (ISO19011: 2018) A case study at the Ministry of Construction, Housing and General Municipalities/Audit Directorate
...Show More Authors

The current research seeks to achieve several objectives, including knowing the extent of the audit directorate of the Ministry of Construction, Housing and General Municipalities of the International Standard (ISO19011:2018) regarding determining the efficiency and evaluation of auditors and diagnosing the gap between requirements and application and knowing the reasons for not applying some of the items in the standard, starting from the problem, The field raised the following question (Does the audit directorate determine the efficiency and evaluation of auditors according to the standard ISO19011:2018?), and the importance of research lies in determining the return that can be achieved by the directorate through its application of stand

... Show More
View Publication Preview PDF