A Simple, rapid and sensitive extractive and spectrophotometric method has been described for the analysis of diphenhyldramine –HCl (DPH) in pure form and in pharmaceutical formulations. The method is based on the formation of chloroform soluble ion-pair complex with Bromophenol blue(BPB) in a phthalate buffer at pH 3.0.The extracted complex shows maximum absorbance at 410 nm. Beer's law is obeyed in the concentration range 0.2-25.0 µg.ml-1. The molar absorptivity and Sandell's sensitivity for the system being 2.416x104 L.mol-1.cm-1 and 0.012µg.cm-2, respectively. The limit of detection was found to be 0.155 µg.ml-1. The proposed method was successfully applied to the determination of the drug in pharmaceutical formulation and satisfactory results were obtained.
The ion-pair formation method has been applied for the spectrophotometric determination of Cimetidine and Erythromycin ethylsuccinate, in bulk samples and in dosage form. The methods are accurate, simple, rapid, inexpensive and sensitive depending on the extraction of the formed ion-pair with brompthymol blue (BTB) as a chromogenic reagent in chloroform, use phthalate buffer of pH 5.5 and 4.0 for Cimetidine and Erythromycin ethylsuccinate respectively. The formed complexes show absorbance maxima at 427.5 nm and 414.5 nm for Cimetidine and Erythromycin ethylsuccinate respectively against reagent blank. The calibration graphs are linear in the ranges of 0.5-15 µg.mL-1 with detection limit of 0.222 µg.mL-1 for
... Show MoreA spectrophotometric determination of azithromycin was optimized using the simplex model. The approach has been proven to be accurate and sensitive. The analyte has been reacted with bromothymol blue (BTB) to form a colored ion pair which has been extracted in chloroform in a buffer medium of pH=4 of potassium phthalate. The extracted colored product was assayed at 415 nm and exhibited a linear quantification range over (1 - 20) g/ml. The excipients did not exhibit any interferences with the proposed approach for assaying azithromycin in pharmaceutical formulations.
Two simple and sensitive spectrophotometric methods are proposed for the determination of amitriptyline in its pure form and in tablets. The first method is based on the formation of charge- transfer complex between amitriptyline as n-donor and tetracyano-ethylene (TCNE) as πacceptor. The product exhibit absorbance maximum at 470 nm in acetonitrile solvent (pH =9.0 ) . In the second method the absorbance of the ion- pair complex, which is formed between the soughted drug and bromocresol green (BCG), was measured at 415 nm at ( pH=3.5) . In addition to classical univariate optimization, modified simplex method (MSM) was applied in the optimization of the variable affecting the color producing reaction by a geometric simple
... Show MoreDrug overdose and poisoning are common clinical problems and could occur with Diphenhydramine hydrochloride (DFH) (one of anti histaminic drug ). It therefore important to study the adsorption of the DFH on pharmaceutical adsorbents which could serve as possible antidotes for the emergency treatment of DFH overdose or poisoning when they occur. The rate and extent of adsorption of DFH on some pharmaceutical adsorbents, bauxite were investigated spectra photometrically also the effect temperature, pH, presence of sucrose as additive have been studied as well, adsorbent's weight and partical size.The equilibrium adsorption contact times were determined for clay surface. Adsorption isotherms have been analyzed by the freundlich model. The appa
... Show MoreCharge transfer complex formation method has been applied for the spectrophotometric determination of erythromycin ethylsuccinate, in bulk sample and dosage form. The method was accurate, simple, rapid, inexpensive and sensitive depending on the formed charge- transfer complex between cited drug and, 2,3- Dichloro-5,6-dicyano-p- benzoquinone (DDQ) as a chromogenic reagent. The formed complex shows absorbance maxima at 587 nm against reagent blank. The calibration graph is linear in the ranges of (10 - 110) μg.mL-1 with detection limit of 0.351μg.mL-1. The results show the absence of interferences from the excipients on the determination of the drug. Therefore the proposed method has been successfully applied for the determination of eryth
... Show MoreA simple, rapid, accurate and sensitive spectrophotometric method is proposed for the detennination of chlorprQm<tZine -HCl in pwe form and in pharmaceutical formulation. This method is based on the formation. of ion assodation complexes of dmg with either thymol
blue or bromophenol blue in an acidic buffer at pH values 4.17 and
3.68, respectively.
The ion-pair complexes formed exhibit absorption maxima at 41 Onm for both thymol blue and bromophenol blue. These complexes· are quantitatively extracted &n
... Show MoreThis approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo
... Show MoreA selective and sensitive spectrophotometric extraction method was established and used to estimate antihypertensive drug, losartan potassium. The method is based on the formation of blue ion pair of the anionic drug, losartan, and the cationic dye, methylene blue, at adjusted pH 6.5 in aqueous solutions, followed by quantitative extraction to dichloromethane;.The observed maximum absorbance was at π 654.9 nm. With 4.53321 x 105 M-1 cm-1 molar absorptivity, Beer's law was obeyed within a concentration range of 0.03-1.5 μg / ml. The limit of detection and the limit of quantification were 0.01μg / ml and 0.03μg / ml, respectively. The method's precision was estimated by a relative standard devi
... Show More