Preferred Language
Articles
/
jih-850
Synthesis of Barbiturate Derivatives of D-Erythroascorbic Acid
...Show More Authors

 The   aim  of   this   work   is   the   synthesis  of   new   derivatives  of   barbiturate   of  D-erythroascorbic acid. To obtain these derivatives, the 5,6-O-isopropylidene-L-ascorbic acid (4) was chosen, which was prepared from the reaction of L-ascorbic acid (3) as a starting material with dry acetone in the presence of hydrogen chloride. The esterification of hydroxyl groups at C-2 and C-3 positions with excess of benzoyl chloride in dry pyridine was obtained compound (5). Hydrolysis for compound (5) in acetic acid (65%) gave the compound (6). Oxidation of the product (6) with sodium periodate results an Aldehyde (7), which was reacted with dimethyl malonate in the presence of potassium hydroxide to give the malonate (8). The cyclocondensation reaction for compound (8) with urea, thiourea and guanidine hydrochloride gave the following compounds (9), (10) and (11) respectively.      All these compounds were characterised by Thin Layer Chromatography (TLC) and FTIR spectra and some were characterised by (U.V-Vis) spectra, 1HNMR spectra and 13CNMR spectra.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 01 2020
Journal Name
Egyptian Journal Of Chemistry
Preparation and Characterization of Graphene Oxide – Attapulgite composite and its use in kinetic study of Alizarin Dye Adsorptionfrom Aqueous Media
...Show More Authors

ATTAPULGITE clay was modified in this study by the graphene oxide sheets and the clay was diagnosed before and after modification using several techniques (Fourier-transform infrared spectroscopy FT-IR, X-ray powder diffraction XRD, Scanning electron microscope SEM , energy dispersive spectroscopy EDX ) ,The surface of the attapulgite clay (before (Ata) after modification by graphene oxide (Ata-GO) ) was applied to adsorption of the Alizarin dye from its water solutions through the application of several kinetic models (pseudo first-order model , pseudo second -order model , intraparticle diffusion model ),It was found that the practical results follow pseudo second -order model. The process of modification on the surface of the mud has imp

... Show More
Publication Date
Sun Jun 01 2014
Journal Name
Alustath Journal For Human And Social Sciences
Obstacles to the application of electronic management in university libraries: the universities of Baghdad and Al-Mustansiriya as a model.
...Show More Authors

The research aims to identify the obstacles facing the application of electronic management in our university libraries, including the central library of the University of Baghdad and the central library of Al-Mustansiriya University, the research sample, as they are among the main libraries that used electronic technologies in managing some of their work and in providing their services, and they have a website via the Internet. The research relied on the case study method to identify the obstacles by visiting the two libraries, interviewing their managers and employees responsible for the departments, and answering inquiries about the obstacles that prevent the application of electronic management in order to identify them and find appropr

... Show More
Preview PDF
Publication Date
Tue Aug 30 2016
Journal Name
Mechanical Engineering
The Effect of Different Furrow Depths and Speeds of Machinary Units Using A Locally Assembled Combine Implement on Planting Maize
...Show More Authors

View Publication
Publication Date
Sat Nov 16 2019
Journal Name
Journal Of Global Pharma Technology
Partial purification of leucine aminopeptidase and its correlation with some biochemical parameters in sera of subclinical hyperthyroidism and hyperthyroidism patients.
...Show More Authors

he study aimed to purify of Leucine aminopeptidase (LAP) from sera of hyperthyroidism patients and its relation to some thyroid hormones (TSH, T 3 , T 4 ) of subclinical hyperthyroidism and hyperthyroidism patients with lipid peroxidation levels that may be play a role in this diseases. Specimens were collected during the time from Nov 2017 until Jan 2018 from Endocrine and Diabetes Center, blood samples were collected from fifty healthy control and one hundred patients, patients were divided into two groups consisted of (50) with hyperthyroidism and (50) with subclinical hyperthyroidism. The aged for all subjects ranged (15-60) years with body mass ranged ((25- 29) kg/m 2 . The purification is done by addition of ammonium sulfate, dial

... Show More
Publication Date
Thu Dec 01 2022
Journal Name
Al-kut University College Of Humanities
The values ​​of environmental sustainability among the student-teacher at the College of Education for Pure Sciences, Ibn al-Haytham
...Show More Authors

Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Journal Of Namibian Studies
consciousness of green nanotechnology among chemistry scholers at the College of Education for Pure Sciences, Ibn al-Haytham in Iraq
...Show More Authors

Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of Bond Strength of Acrylic Artificial Teeth with Unreinforced and Nano Silica Reinforced Denture Base Material after Chemical Disinfection
...Show More Authors

Soaking dentures with disinfection solutions is an effective way of keeping dentures in a healthy status; however, immersions in these solutions have a negative effect on the bond strength of denture base and denture teeth. The aim of this study was to evaluate the bond strength between denture acrylic teeth and heat-cured Poly (methyl methacrylate) denture base material (with and without nano silica) after disinfection with different chemical disinfectants for a simulated period of six months. One hundred specimens of maxillary central incisors attached to PMMA were divided into two groups; 50 specimens of PMMA without nano silica and 50 specimens of PMMA reinforced with 5 wt% of nano silica. Specimens of each group were immersed in five i

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Rawal Medical Journal
Macular thickness correlation with gender and age in a sample of healthy eyes of Iraqi population utilizing optical coherence tomography
...Show More Authors

Preview PDF
Scopus
Publication Date
Fri Jan 03 2020
Journal Name
Chalcogenide Letters
THE EFFECT OF Ag CONTENT AND HEAT TREATMENT ON STRUCTURAL AND MORPHOLOGICAL PROPERTIES OF THIN (Cu1-xAgx)2 ZnSnSe4 FILMS
...Show More Authors

(Cu1-x,Agx)2ZnSnSe4 alloys have been fabricated with different Ag content(x=0, 0.1, and 0.2) successfully from their elements. Thin films of these alloys have been deposited on coring glass substrate at room temperature by thermal evaporation technique under vacuum of 10-5Torr with thickness of 800nm and deposition rate of 0.53 nm/sec. Later, films have been annealed in vacuum at (373, and 473)K, for one hour. The crystal structure of fabricated alloys and as deposited thin films had been examined by XRD analysis, which confirms the formation of tetragonal phase in [112] direction, and no secondary phases are founded. The shifting of main polycrystalline peak (112) to lower Bragg’s angle as compared to Cu2ZnSnSe4 angle refers to incorpora

... Show More
Preview PDF
Publication Date
Wed May 01 2019
Journal Name
Journal Of Global Pharma Technology
Application of H-Point Standard Addition Method in Kinetic- Spectrophotometric Determination of Phenylephrine in Nasal Drops and Tetracycline in Capsule
...Show More Authors

A new simultaneous spectrophotometric-kinetic method was developed to determine phenylephrine (PHEN) and tetracycline (TETR) via H-point standard addition method (HPSAM). The proposed procedures rely on the measurements of the difference in the rate of charge-transfer (CT) reaction between each of PHEN and TETR as electron donors with p-Bromanil (p-Br) as an electron acceptor. Different experimental factors which affect the extent of the complex formation were investigated by monitoring the value of absorbance at 446 nm. Time pair of 50 -100 sec was selected and employed, among different examined pairs since it results in the highest accuracy for HPSAM-plot. Linear calibration graphs in the concentration ranges of 10.0-40.0 and 10.0–50.0

... Show More