Projective Properties for Symmetrical Magnetic Lens by Using Exponential Model
...Show More Authors

A computational investigation is carried out in the field of charged particle optics with the aid of the numerical analysis methods. The work is concerned with the design of symmetrical double pole piece magnetic lens.  The axial magnetic flux density distribution is determined by using exponential model, from which the paraxial-ray equation is solved to obtain the trajectory of particles that satisfy the suggested exponential model.  From the knowledge of the first and second derivatives of axial potential distribution, the optical properties such as the focal length and aberration coefficients (radial distortion coefficient and spiral distortion coefficient) are determined.  Finally, the pole piece profiles capable of producing the assign were determined.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Science
Synthesis, Characterizations, and Magnetic Properties of Mixed Spinel Mg1-xZnxFe2O4 Ferrites
...Show More Authors

    Mixed spinel Mg1-xZnxFe2O4 ferrites (where x = 0, 0.2, 0.4, and 0.6) nanoparticles were synthesized by using microwave-assisted combustion route. As-synthesized powdered samples were checked by XRD analysis, field emission-scanning electron microscopy, and vibration sample magnetometer to investigate the structural,   morphology, and magnetic properties, respectively. XRD results exhibited that the crystallite size increases with the decrease of Zn+2 ion concentration for series of mixed spinel Mg1-xZnxFe2O4 ferrite expect x=0.2. All the mixed spinel Mg1-xZnxFe2O4 ferrite has different gr

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Mon Sep 06 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Using Micro-Ceramic as an Abrasive Material to Remove Surface Roughness by Magnetic Abrasive Finishing
...Show More Authors

Due to the rapid advancement of technology and the technology of things, modern industries start to need a highprecision equipment and surface finishing, so many finishing processes began to develop. One of the modern processes is Magnetic Abrasive Finishing (MAF), which is a high-precision process for internal and external finishing under the influence of a magnetic field of abrasive particles. Boron Carbide (B4C) ceramics was tested by mixing it with iron (Fe) and produced abrasive particles to reduce the intensity of scraping on the surface, reduce the economic cost and achieve a high finishing addition to remove the edges at the same time. The material selected for the samples was mild steel (ASTM E415) under (Quantity of Abrasives, Mac

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 27 2022
Journal Name
Iraqi Journal Of Science
The Dependence of The Gravitational Lensing Properties on The Lens And Source Redshifts
...Show More Authors

    This work aims to investigate the dependence of gravitational lensing properties on the lens redshift and source redshift.

The angular diameter distance hereafter referred to as ADD has been determined using two different numerical integral methods, Simpson's rule, and definite integral methods. Both of those two methods gave identical results. In addition, observational data of gravitational Lensing systems have been used to find the most probable value of lens redshift and source redshift. The result showed that the lens redshift and source redshift are more likely to occur in the ranges of zL=0.2-0.6 and zS=1-3, respectively.

Einstein radius and the critical surface mass density

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Matec Web Of Conferences
Brain Tumour Detection using Fine-Tuning Mechanism for Magnetic Resonance Imaging
...Show More Authors

In this paper, new brain tumour detection method is discovered whereby the normal slices are disassembled from the abnormal ones. Three main phases are deployed including the extraction of the cerebral tissue, the detection of abnormal block and the mechanism of fine-tuning and finally the detection of abnormal slice according to the detected abnormal blocks. Through experimental tests, progress made by the suggested means is assessed and verified. As a result, in terms of qualitative assessment, it is found that the performance of proposed method is satisfactory and may contribute to the development of reliable MRI brain tumour diagnosis and treatments.

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Evaluation of Brain Stem Function in Diabetics with and Without Distal Symmetrical Polyneuropathy Using the Blink Reflex
...Show More Authors

 Background: Diabetic peripheral neuropathy (DPN) is the commonest complication of T2DM. Neuropathy is a descriptor for a spectrum of clinical and subclinical symptoms with varying anatomical distributions, clinical histories, and perhaps underlying pathogenetic mechanisms. The distal Symmetrical sensory polyneuropathy is chronic, symmetrical, length-dependent sensorimotor. Studies of the blink reflex have shown potential as a method of assessing brainstem activity.

Objective: The primary purpose of this research was to assess the function of the blink reflex in the early detection of cranial nerves and brain

... Show More
View Publication
Crossref
Publication Date
Tue Feb 13 2024
Journal Name
Iraqi Journal Of Science
Systems Reliability Estimations of Models Using Exponentiated Exponential Distribution
...Show More Authors

This article deals with estimations of system Reliability for one component, two and s-out-of-k stress-strength system models with non-identical component strengths which are subjected to a common stress, using Exponentiated Exponential distribution with common scale parameter. Based on simulation, comparison studies are made between the ML, PC and LS estimators of these system reliabilities when scale parameter is known.

View Publication Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Subgroups and Orbits by Companion Matrix in Three Dimensional Projective Space
...Show More Authors

The aim of this paper is to construct cyclic subgroups of the projective general linear group over  from the companion matrix, and then form caps of various degrees in . Geometric properties of these caps as secant distributions and index distributions are given and determined if they are complete. Also, partitioned of  into disjoint lines is discussed.

View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Iraqi Journal Of Physics
Calculation of the Magnetic Dipole and Electric Quadrupole Moments of some Sodium Isotopes using Shell Model with Skyrme Interaction
...Show More Authors

         In the present work, the magnetic dipole and electric quadrupole moments for some sodium isotopes have been calculated using the shell model, considering the effect of the two-body effective interactions and the single-particle potentials. These isotopes are; 21Na (3/2+), 23Na (3/2+), 25Na (5/2+), 26Na (3+), 27Na (5/2+), 28Na (1+) and, 29Na (3/2+). The one-body transition density matrix elements (OBDM) have been calculated using the (USDA, USDB, HBUMSD and W) two-body effective interactions carried out in the sd-shell model space. The sd shell model space consists of the active 2s1/2, 1d5/2,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Materials Science And Engineering
Effect of magnetic water on strength properties of concrete
...Show More Authors
Abstract<p>The research’s main goal is to investigate the effects of using magnetic water in concrete mixes with regard to various mechanical properties such as compressive, flexural, and splitting tensile strength. The concrete mix investigated was designed to attain a specified cylinder compressive strength (30 MPa), with mix proportions of 1:1.8:2.68 cement to sand to crushed aggregate. The cement content was about 380 kg/m<sup>3</sup>, with a w/c ratio equal to 0.54, sand content of about 685 kg/m3, and gravel content of about 1,020 kg/m3. Magnetic water was prepared via passing ordinary water throughout a magnetic field with a magnetic intensity of 9,000 Gauss. The strength test</p> ... Show More
Crossref (6)
Crossref
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Science
Reliability Estimation for the Exponential-Pareto Hybrid System
...Show More Authors

     The reliability of hybrid systems is important in modern technology, specifically in engineering and industrial fields; it is an indicator of the machine's efficiency and ability to operate without interruption for an extended period of time. It also allows for the evaluation of machines and equipment for planning and future development. This study looked at reliability of hybrid (parallel series) systems with asymmetric components using exponential and Pareto distributions. Several simulation experiments were performed to estimate the reliability function of these systems using the Maximum Likelihood method  and the Standard Bayes method  with a quadratic loss (QL) function and two priors: non-informative (Jeffery) and inform