The Nano compound (Ba1-xSrxTiO3) as (X=0,0.26,0.28,0.30,0.32,0.34) was synthesized by using sol-gel method, the structural properties of result compound were studied by using xray diffraction test (XRD) and scanning electron microscope (SEM). the results were exhibited and by using software indexing to x-ray diffraction pattern that all prepared samples possess tetragonal phase and there is not any other phases were existed. also the substitution process didn't change the phase of compound and increase in (Sr+2) ion concentration leads to decrease lattice parameters (a,c) then the unite cell volume was decreased, as the particle size calculated from Debye-Scherrer and Williamson-Hall equations , and the calculated density from x-ray diffraction spectrum exhibited they were decreased with increase of (Sr+2) ion concentration, and scanning electron microscope pictures showed that prepared particles take a shape-like spherical shape.
The study aims to demonstrate the importance of instructional methods in teaching Arabic language as a second language or teaching the Arabic language to non-native speakers. The study is in line with the tremendous development in the field of knowledge, especially in the field of technology and communication, and the emergence of many electronic media in education in general and language teaching in particular. It employs an image in teaching vocabulary and presenting the experience of the Arabic Language Institute for Non-Speakers-King Abdul-Aziz University. The study follows the descriptive approach to solve the problem represented by the lack of interest in the educational methods when teaching Arabic as a second language. Accordingl
... Show MoreTwo well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show Moreالمستودع الرقمي العراقي. مركز المعلومات الرقمية التابع لمكتبة العتبة العباسية المقدسة