Preferred Language
Articles
/
jih-726
Gas Sensitivity and Optical Detector of Indium Oxide films
...Show More Authors

In this research, we studied the structural and optical properties of  In2O3 films which prepared by chemical spray pyrolysis method on the glass substrate heated 400  . The effect of annealing temperature 100 for one hour on theses properties are studied. The result of Xray diffraction showed the prepared films were polycrystalline and orientation was (222) before and after annealing, optical properties study for prepared films by using (UV-VIS-NIR) spectrophotometer in the wave length range (300-1100)nm, We found the transmission increases after annealing to 90%. Sensitivity measurement of In2O3 films for gas (CO) and optical detector showed that after annealing at temperature 100 .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 23 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Detection of Uropathogens in Urinary Tract Infection and Their Sensitivity to Many Antimicrobial Agents
...Show More Authors

    Urinary tract infections (UTI) are some of the most common infections experienced by humans, exceeded in frequency among ambulatory patient only by respiratory and gastrointestinal infections. It is also the most common cause of nosocomial infection in adults.   A total of three hundred urine sample were collected in age (1-69 years old)   in both gender, with (UTI) symptoms referred to AL-Yarmok Teaching Hospital at Baghdad city during the period from January 2010 till August 2010.  The commonest isolates were Escherichia coli (E.Coli), Proteus mirabilis and Klebsiella pneumoniae (These represented 49.2%, 22 %, and16 % of isolates respectively). The percentage of bacteria incidence in females

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
The optical properties of mawsonite Cu6Fe2SNS8 [CFTS] thin films effected by red laser irradiation deposited via semi-computerized spray pyrolysis technique
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Nonlinear optical properties of polymer [PMMA] thin films doped with dye lasing compounds, Rhodamine 6G and Acriflavine in chloroform solvent by using dip coating method
...Show More Authors

The fluorescence emission of Rhodamine 6G (R6G) and Acriflavine dyes in PMMA polymer have been studied by changing the irradiation and exposure time of laser light to know the effect of this parameter. It was found that the fluorescence intensity decreases in the polymer samples doped dyes as the exposure time increases and then reaches stabilization at long times, this behavior called photobleaching, which have been shown in liquid phase less than solid phase. Using 2nd harmonic with wavelength 530 nm laser, the photobleaching effect in the two dye-doped polymers different solvent but same was studied. It was observed that photobleaching of by different solution and by using dip spin coating the photobleaching seem in liquid phase more

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Investigation of Beta and Gamma Rays Total Interaction Cross Section and Effective Atomic Number for CR-39Nuclear Track Detector
...Show More Authors

CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays a

... Show More
View Publication Preview PDF
Publication Date
Mon May 28 2018
Journal Name
Iraqi Journal Of Science
Propose retina identification system based on the combination of SURF detector and BRISK descriptor
...Show More Authors

     In this paper the design of hybrid retina matching algorithm that is used in identification systems is considered. Retina based recognition is apparent as the most secure method for identification of an identity utilized to differentiate persons.

     The characteristics of Speeded up Robust Feature (SURF) and Binary Robust Invariant Scalable Key-Points (BRISK) algorithm have been used in order to produce a fast matching algorithm than the classical ones, those characteristics are important for real-time applications which usually need quick processing of a growing quantity of data. The algorithm is divided into three stages: retinal image processing and segmentation, extracting the lo

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oxidative Desulfurization of Simulated Diesel Fuel by Synthesized Tin Oxide Nano-Catalysts Support on Reduced Graphene Oxide
...Show More Authors

   The modified Hummers method was applied to prepare graphene oxide (GO) from the graphite powder. Tin oxide nanoparticles with different loading (10-20 wt.%) supported on reduced graphene oxide were synthesized to evaluate the oxidative desulfurization efficiency. The catalyst was synthesized by the incipient wetness impregnation (IWI) technique. Different analysis methods like FT-IR, XRD, FESEM, AFM, and Brunauer-Emmett-Teller (BET) were utilized to characterize graphene oxide and catalysts. The XRD analysis showed that the average crystal size of graphene oxide was 6.05 nm. In addition, the FESEM results showed high metal oxide dispersions on the rGO. The EDX analysis shows the weight ratio of Sn is close to its theoretical weight.

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi Journal Of Science
Real-Night-time Road Sign Detection by the Use of Cascade Object Detector
...Show More Authors

     Variations in perspective, illumination, motion blur, and weatherworn degeneration of signs may all be essential factors in road-sign identification. The current research purpose is to evaluate the effectiveness of the image processing technique in detecting road signs as well as to find the appropriate threshold value range for doing so. The efficiency of the cascade object detector in detecting road signs was tested under variations of speed and threshold values. The suggested system involved using video data to calculate the number of frames per second and creating an output file that contains the specified targets with their labels to use later in the final process (i.e., training stage). In the current research, two videos

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Natural radioactivity Measurements of Dur-Kurigalzu's Ziggurat, Baghdad Governorate-Iraq using HPGe detector
...Show More Authors

       Measurement of 238U, 233Th and 40K concentrations in soil samples collected from Ziggurat of Dur-Kurigalzu west region of Baghdad, have been evaluated, using high purity germanium detector. The activity concentrations of 238U, 233Th and 40K varied from 16.040  to 26.620 , 14.510  to 31.480 , and 153.820  to 266.320  with average values of 20.604±2.9 , 24.534±3.3 , 212.22±25.1 , respectively. The importance of these measurements lies in the estimation of radiation risk, radium equivalent, absorbed dose, annual effective dose, risk indices, gamma index, and cancer risk. The average value of the absorbed dose ranged from 33.187  outdoors to 63.111  indoo

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Calculation of Full Energy Peak Efficiency for HPGe Detector Using Monte Carlo Method
...Show More Authors

This research presents results on the full energy peak efficiency of a high purity germanium (HPGe) detector from point source as a function of photon energy and source-detector distance. The directions of photons emitted from the source and the photon path lengths in the detector were determined by Monte Carlo technique. A major advantage of this technique is the short computation time compared to the experiments. Another advantage is the flexibility for inputting detector-related parameters (such as source–detector distance, detector radius, length and attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. It has been designed and writte

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Assessment of High Sensitivity C.Reactive Protein in male patients with metabolic syndrome and atherosclerosis complications
...Show More Authors

Background: syndrome X or metabolic syndrome is a collection of multiple diseases mainly visceral obesity , hypertriglyceridemia , decrease HDL level, hypertension and elevated fasting blood glucose that lead to accelerated atherosclerosis through multiple mechanisms, one of the most important is increase inflammation of the vessels manifested by elevated high sensitivity C reactive protein (hs-CRP).Objective: The aim of the study was to assess the prevalence of elevatedhs CRP in people with metabolic syndrome and atherosclerosis complication (IHD, Cerebrovascular disease, peripheral vascular disease) and metabolic syndrome without these complication.Patients and methods:;This is a cross sectional study carried out in Diabetic referral c

... Show More
View Publication Preview PDF