Preferred Language
Articles
/
jih-710
Enhancement of Stream Cipher by Using Variant Register in Length

         Stream ciphers are an important class of encryption algorithms. There is a vast body of theoretical knowledge on stream ciphers, and various design principles for stream ciphers have been proposed and extensively analyzed. This paper  presents a new method of stream cipher, that by segmenting the plaintext into number of register then any of them combined to any other by using combination logic circuit (And, OR, JK, NOT, XOR), then using variant register in length as a key which provides security enhancement against attacks and then compare the strength of this method with RSA by calculaing the time necessary to get the original text by using the genetic algorithm. And the way that has the longest time is the best in encryption. Then it was found that proposed method is stronger in encryption than RSA.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun May 10 2020
Journal Name
Baghdad Science Journal
Lack of Association between LCS6 Variant in KRAS Gene with the Occurrence of Breast Tumors in Iraqi Women

Breast cancer is the most commonly diagnosed cancer and remains one of the main reasons of cancer-related mortality in women worldwide. KRAS variant rs61764370 (T>G) is associated with an increased risk of occurrence of many cancers, Here The case-control study was accomplished on 135 women including 45 women with breast cancer patients, 45 women with benign breast lesions and 45 healthy women to analyze the association of KRAS variant rs (61764370 T>G) with breast cancer. LCS 6 variant in KRAS gene was amplified by using specific primers, then genotype was detected after sequencing the PCR products. The results showed that the genotype and allele frequency of TT and GT allele of  KRAS

... Show More
Scopus (3)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Tue Jan 18 2022
Journal Name
Iraqi Journal Of Science
The Fuzzy Length of Fuzzy Bounded Operator

In this paper we recall the definition of fuzzy length space on a fuzzy set after that we recall basic definitions and properties of fuzzy length. We define fuzzy bounded operator as an introduction to defined fuzzy length of an operator then we proved that the fuzzy length space FB ̃ ̃ consisting of all fuzzy bounded linear operators from a fuzzy length space ̃ into a fuzzy length space ̃ is fuzzy complete if ̃ is fuzzy complete. Also we proved that every finite dimensional fuzzy length space is fuzzy complete.

View Publication Preview PDF
Publication Date
Mon Dec 05 2022
Journal Name
F1000research
Enhancement of surface properties of polyetheretherketone implant material by fractional laser texturing

Background: Polyetheretherketone (PEEK) is a promising implant material due to its superior biomechanical strength. However, due to its hydrophobic nature and lack of cellular adhesion properties, it has poor integration with bone tissue. Methods: A fractional CO2 laser was used with various parameters for surface texturing of PEEK substrate to enhance its surface properties. An optical microscope and field-emission scanning electron microscope (FESEM) were used to examine the surface morphology of untextured and laser-textured samples. Energy dispersive X-ray spectroscopy (EDX) was performed to determine the effect of the laser on the microstructure of PEEK. Surface microroughness, atomic force microscopy (AFM), and wettability were invest

... Show More
Crossref (3)
Scopus Crossref
View Publication Preview PDF
Publication Date
Mon Jan 09 2023
Journal Name
2023 15th International Conference On Developments In Esystems Engineering (dese)
Scopus (2)
Crossref (1)
Scopus Crossref
View Publication
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Body mass index and shortened telomere length in middle-aged female and male RUNNING HEAD: Middle-aged and shortened telomere length

Obesity is a risk factor associated with age-related disorders that accelerate aging, and it increases the risk of metabolic diseases. Therefore, this study was conducted to investigate the association of leukocyte telomere length (LTL) with the presence of higher body weight in middle-aged females and males. The study subjects comprised 160 (80 control and 80 higher body mass index BMI groups) with ranging ages of 30-50 years included and stratified for BMI. The physio-biochemical analysis was measured using enzymatic determination. Mean telomere length was determined by using the southern blotting technique. The association analysis revealed a significant variance (P < 0.01) in biochemical parameters between higher BMI grou

... Show More
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Thu Jul 28 2016
Journal Name
Computer And Information Science
Refinement for Ocular Ultrasound Images Quality by Utilizing Combination of Enhancement Techniques

Ultrasound has been used as a diagnostic modality for many intraocular diseases, due its safety, low cost, real time and wide availability. Unfortunately, ultrasound images suffer from speckle artifact that are tissue dependent. In this work, we will offer a method to reduce speckle noise and improve ultrasound image to raise the human diagnostic performance. This method combined undecimated wavelet transform with a wavelet coefficient mapping function: where UDWT used to eliminate the noise and a wavelet coefficient mapping function used to enhance the contrast of denoised images obtained from the first component. This methods can be used not only as a means for improving visual quality of medical images but also as a preprocessing

... Show More
Crossref
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Enhancement of functionalized carbon nanotubes gas sensor by adding metal oxide nanoparticles

Functionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p

... Show More
Crossref (4)
Crossref
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Enhancement of Electron Temperature under Dense Homogenous Plasma by Pulsed Laser Beam

The applications of hot plasma are many and numerous applications require high values of the temperature of the electrons within the plasma region. Improving electron temperature values is one of the important processes for using this specification in plasma for being adopted in several modern applications such as nuclear fusion, plating operations and in industrial applications. In this work, theoretical computations were performed to enhance electron temperature under dense homogeneous plasma. The effect of   power and duration time of pulsed Nd:YAG laser   was studied on the heating of   plasmas  by inverse bremsstrahlung  for  several values for the electron density ratio. There results for these ca

... Show More
Scopus (3)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Tue Jan 18 2022
Journal Name
Iraqi Journal Of Science
Contrast Enhancement of the Mammographic Image Using Retinex with CLAHE methods

Recently digital mammography is most widely used technology for early detection of breast cancer. The main diagnosing elements such as lesion or masses in digital mammograms are with law contrast. The purpose of this paper is to enhance the mammogram images by increasing its contrast. Different enhancement method are used for this purpose such as histogram equalization (HE), Contrast Limited Adaptive Histogram Equalization (CLAHE), Morphological, and Retinex. The Retinex method also implement by combining it with HE once, and with CLAHE to improve its performance. The experimental results show that using Retinex with CLAHE can produce an image with enhancement in contrast better than using it with HE method and better than other methods

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Science
Water quality assessment of Rawanduz River and Gali Ali Beg stream by applied CCME WQI with survey aquatic insects (Ephemeroptera)

The population of Ephemeroptera was studied in three selected stations of Rawanduz River (Gali Ali Beg water fall, Rawanduz River and after the junction of these two waters) during the three seasons of spring, summer and autumn in 2016. In addition,sixteen physicochemical parameters (pH, EC, turbidity, DO, BOD5, NO3, TDN, TDP, HCO3-, Hardness, Ca2+, Mg2+, Na+, K+, Cl-, SO42-, Na% and SAR) of water in these stations were estimated and used to calculate the Canadian Council of Ministers of the Environment Water Quality Index (CCME WQI). Eleven species of aquatic insects were identified,which belong to four families of th

... Show More
Scopus (9)
Crossref (1)
Scopus Crossref
View Publication Preview PDF