Waters of some wells at Almuqdadea region Diyala province, east of Iraq have been
compared with wells at Alfalluja region, Alanbar province west of Iraq. Five wells were
selected randomly at each of the two regions to measure several factors represented by
temperature (C), P
H
, Electric Conductivity (EC), Sodium (Na),Calcium (Ca), Magnesium
(Mg),Total Hardness (TH), Carbonate (Co3),Chloride (Cl), Nitrite (NO2), Nitrate (NO3)
Phosphate (PO4) Sulfate (So4), in addition to the heavy metals such as Chromium (Cr),
Cadmium (Cd) Lead (Pb) & Iron (Fe). The mean concentration of the above factors in water
of wells at the above regions had been measured during the period from April to September
(2010).
Results of the present study revealed that all the heavy metals concentrations were less
than the sensitivity of the atomic absorption equipment with the exception of (Fe) which
recorded 0.358 ppm and 0.026 ppm at Alfalluja and Almuqdadea respectively. Results of the
present study were compared with the criteria used by (WHO) and (FAO). Results of the
present study revealed that all the metals concentration were undetectable by atomic
absorption equipment with the exception of (Fe) which recorded 0.358 ppm and 0.026 ppm at
Alfalluja and Almuqdadea respectively. The results showed that all concentrations recorded in
the present study were accepted with the international criteria used by the above organizations
except for EC, NO3, TH, and Na from Alfalluja wells as their levels were (2.208 m/sm,1.506
546.5 ppm, 3.53 gm/l) respectively. The unacceptable data from Almuqdadea wells were
represented by EC, TH, Mg and Na where their levels were (1170MGS\SM, 512.86ppm,
213.34ppm, 2.31gm\L) respectively. Finally the results showed that there were similarities in
the concentrations of some factors studied in the present project in the wells of the same area
and in some factors at both areas of study.
Detection of virulence gene agglutinin-like sequence (ALS) 1 by using molecular technology from clinical samples (
The study aimed to establish the association of miR-153-3p expression with treatment response to IM in CML patients. Sixty CML patients were included and divided into two groups consistent with their response to treatment whether sensitive or resistant to IM. Ten healthy normal participants were enrolled as control group. RNA was extracted from serum to work out miR-153-3p expression utilizing real-time quantitative reverse transcription polymerase chain reaction. The primers were supplied by Macrogen Inc. Twenty seven patients were sensitive to imatinib and 33 were resistant to imatinib. The ratio of male to female was 1.14:1. The bulk (58%) of patients were within the age range of 41-60 years. Weight and gender did not significantly diffe
... Show MoreThe aim of this study to determine the genetic distance and relationship among some Iraqi date palm cultivars by using the Random Amplified Polymorphic DNA (RAPD) technique. Molecular analysis was performed by using 10 random primers. These primers produced 176 fragment lines across 14 cultivars, Of these, 166 or 94.3% were polymorphic. The size of the amplified bands ranged between 200-2250 bp. The genetic polymorphism value of each primer was determined and ranged between 7.5-16.9%. In terms of unique banding patterns, the most characteristic banding pattern was for the Barhee cultivar with primer OP-M06 and for the Khadhrawy Mandily cultivar with primer OP-C02. Genetic distance values ranged from 0.868 to 0.125 among studied date palm
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreBackground: Diabetes mellitus a major factor that has adverse effects on the vascular system and the heart. It causes an increase in cardiac muscle thickness, resulting in decreased compliance and increased peripheral arterial stiffness. This study aims to assess the left ventricular mass (LVM) and left ventricular hemodynamic changes in diabetic patients measured by Doppler echocardiography. Patients and Methods: The study included 50 diabetic patients ranging in age between 25 and 80 years, (mean age: 54.1 ± 15.10, 19 males, 31 females) and 50 healthy subjects, aged 25 to 80 years (mean age: 48.52 ± 14.45, 11 males, 39 females). Doppler echocardiography was used to assess left ventricular function. The measurements included
... Show MoreObjectives: To assess nurses-midwives' knowledge about pain management during labor before and after implementation of educational program and to determine the effectiveness of educational program on nurses-midwives' knowledge about pain management during labor in Baghdad Maternity Hospitals.
Methodology: A quasi-experimental design has been conducted during the period of (February 27th 2019 through 2nd June 2019) on non-probability sample (purposive) consists of (44 Nurses/midwives') who are work in delivery room, the sample was exposed to pretest, educational program, posttest. The study was conducted in three Directories, (Baghdad Teaching Hospital) at medical city health
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth