Preferred Language
Articles
/
jih-492
The Measurement of Electromagnetic wave Emitted from Home Appliance by Milligauss meter
...Show More Authors

   The appliance of milligauss meter was designed by Qusay Ismail to measure the induce of electromagnetic field for home appliance which are put at a distance from milligauss meter (15-30-60)cm .The results showed some appliance has recorded higher than normal acceptable level of electromagnetic radiation emissions and produced radiation of (350650)milligauss as for the rest of appliances has recorded values which are ranged between (1200)milligauss ,laptop was recorde radiation generally lower than from desktop and computer moniter (CRT).The radiation ,intensity decrease with increasing distance.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Robust Tests for the Mean Difference in Paired Data by Using Bootstrap Resampling Technique
...Show More Authors

The paired sample t-test for testing the difference between two means in paired data is not robust against the violation of the normality assumption. In this paper, some alternative robust tests have been suggested by using the bootstrap method in addition to combining the bootstrap method with the W.M test. Monte Carlo simulation experiments were employed to study the performance of the test statistics of each of these three tests depending on type one error rates and the power rates of the test statistics. The three tests have been applied on different sample sizes generated from three distributions represented by Bivariate normal distribution, Bivariate contaminated normal distribution, and the Bivariate Exponential distribution.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
A COMPARATIVE STUDY OF THE AMOUNT OF FORCE EXERTED ON THE GROUND AND THE TIME OF PROPULSION IN THE VERTICAL AND HORIZONTAL JUMPING TESTS FROM STABILITY USING A FOOT SCAN DEVICE
...Show More Authors

Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Physics
Fabrication of carbon nanopowder by arc discharge technique
...Show More Authors

Carbon Nanopowder was fabricated by arc discharge technique at deposition pressure of 10-5 mbar Argon gas on glass substrates. The prepared carbon nano- powder was collected from chamber and purified with nitric acid at 323K .The morphology and crystalline structure of the prepared powder was examined by X-Ray Diffraction (XRD), Atomic Force Microscope (AFM), and Scanning Electron Microscope (SEM). XRD spectrums showed that the powder exhibits amorphous structure and after purification, the powder showed hexagonal structure with a preferential orientation along(002) direction ,where AFM and SEM gave very compatible estimation on the grain size and shape of the nanopowder.

View Publication Preview PDF
Publication Date
Sun Mar 26 2023
Journal Name
Wasit Journal Of Pure Sciences
Removal of malachite green by poly acrylic beads
...Show More Authors

This work investigates removing the Malachite Green (MG) dye, the poly acrylic hydrogel beads used as a surface to adsorb the dye, the isotherm of adsorption was examined and aspects that influence it, like increasing heat, adding salt, the influence of dry beads and effect of shaking. according to the results, the effect of the adsorption has been found that it is matched to the Friendlish equation much more than Langmuir and Temkin equations. A positive relationship between the adsorption process and the increase in temperature is found that adsorption increases when the temperature increase. Also, the adsorption increased when the salt was added at a temperature (of 20 C0). As that the adsorption doesn’t budge by adding either

... Show More
View Publication
Crossref (11)
Crossref
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Lithotripsy of Urinary Tract Stones by Using Eggshell
...Show More Authors

 This research aimed to  use eggshell powder as a lithtripsian for different types of urinary stones and determine the efficiency of these preparations against different types of stone.      The grounded and sterilized eggshell was dissolved in fresh lemon juice .The treatment was orally given   for successive 7 days before breakfast.       Eighty five patients with different types of  urinary stone  were participated in this research. All patients were subjected to Ultrasonography and intravenous pyelography examinations to localize the position and detect diameter of the stone. The above examination and also biochemical tests for diagnosis of stones in

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
J. Pharm. Sci. & Res.
Synthesis of coumarin by Pechman reaction - A Review
...Show More Authors

Phenol condensed with β-keto esters via Pechmann condensation to form derivatives of Coumarin in various reaction conditions by two ways. Present paper is comparative study of synthesis Coumarin with the yield of product , reaction time and reaction conditions.

Publication Date
Mon Jan 01 2018
Journal Name
Asian Journal Of Ournal Of Chemistry
Extraction of Ocimum basillicum Oil by Solvents Methods
...Show More Authors

The extraction of Basil oil from Iraqi Ocimum basillicum leaves using n-hexane and petroleum ether as organic solvents were studied and compared. The concentration of oil has been determined in a variety of extraction temperatures and agitation speed. The solvent to solid ratio effect has been studied in order to evaluate the concentration of Ocimum basillicum oil. The optimum experimental conditions for the oil extraction were established as follows: n-hexane as organic solvent, 60 °C extraction temperature, 300 rpm agitation speed and 40:1mL:g amount of solvent to solid ratio.

View Publication
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Research Journal Of Pharmaceutical, Biological And Chemical Sciences
Treating of oil-based drill cuttings by earthworms
...Show More Authors

This study assessed the advantage of using earthworms in combination with punch waste and nutrients in remediating drill cuttings contaminated with hydrocarbons. Analyses were performed on day 0, 7, 14, 21, and 28 of the experiment. Two hydrocarbon concentrations were used (20000 mg/kg and 40000 mg/kg) for three groups of earthworms number which were five, ten and twenty earthworms. After 28 days, the total petroleum hydrocarbon (TPH) concentration (20000 mg/kg) was reduced to 13200 mg/kg, 9800 mg/kg, and 6300 mg/kg in treatments with five, ten and twenty earthworms respectively. Also, TPH concentration (40000 mg/kg) was reduced to 22000 mg/kg, 10100 mg/kg, and 4200 mg/kg in treatments with the above number of earthworms respectively. The p

... Show More
View Publication
Publication Date
Thu Jan 01 2009
Journal Name
Wasit Journal For Science & Medicine
Spectrophotometric Determination of Promethazine Hydrochloride by In (III)
...Show More Authors

A simple, rapid and sensitive spectrophotometirc method for the determination of trace amounts of promethazine hydrochloride in the aqueous solution is described. The method is based on the complexation of promethazine hydrochloride with In (III) in the presence of sodium hydroxide to form an soluble product with maximum absorption at 304nm. Beer’s law is obeyed over the concentration range of (2- 20μg/ml) with molar absorptivity of (1.92× 103 L.mol-1 .cm -1 ). The optimum conditions for all development are described and the proposed method has been successfully applied for the determination of promethazine hydrochloride in bulk drug.

Publication Date
Tue Jun 04 2024
Journal Name
Asian Journal Of Water, Environment And Pollution
Biodegradation of Two Textile Dyes by Bacillus Subtilis
...Show More Authors

This study revealed the efficiency of Bacillus subtilisin degrading two textile dyes (disperse red and disperse yellow), the rates of red dye removal when measured after 24, 48, 72 and 96 hours for the concentrations of 50 ppm were 51.67, 67.56, 84.67 and 95.33%, for the concentration 150 ppm were 41.67, 62.67, 80.67 and 89.67%, while for the concentration 300 ppm were 25.67, 42.67, 71.67 and 84.33%. The results of yellow dye removal showed that the concentration of 50 ppm were 49.67, 65.33, 83.33 and 92.67%, for the concentration of 150 ppm were 38.33, 60.33, 77.33 and 87.33%, and for the concentration, 300 ppm were 24, 36.67, 68.33 and 81.67%, when measured after 24, 48, 72 and 96 hours. Results recorded a slight decrease in pH valu

... Show More
Preview PDF