The present study aimed to investigate the morphological description and histological structure of thyroid gland in Herpestes javanicus . The results revealed that thyroid gland in adult Herpestes javanicus is located in the neck region just below the larynx and attached to the trachea . Histological study revealed that thyroid gland in H. javanicus surrounded by a capsule of losse connective tissue and the thyroid gland mainly formed from follicles within different sizes. The results showed that the follicle consists of three compenets represented by follicular lining cells, basal parafollicular cells and the colloid. Microscopical examination revealed that the follicular lining tissue is either to be simple squamous or simple cuboidal epithelial tissue . The results also showed that the parafollicular cells (C-cells) are spherical, oval and even polygonal, and are located either interfollicular or intrafollicular.
In this research , we study the inverse Gompertz distribution (IG) and estimate the survival function of the distribution , and the survival function was evaluated using three methods (the Maximum likelihood, least squares, and percentiles estimators) and choosing the best method estimation ,as it was found that the best method for estimating the survival function is the squares-least method because it has the lowest IMSE and for all sample sizes
In this research , we study the inverse Gompertz distribution (IG) and estimate the survival function of the distribution , and the survival function was evaluated using three methods (the Maximum likelihood, least squares, and percentiles estimators) and choosing the best method estimation ,as it was found that the best method for estimating the survival function is the squares-least method because it has the lowest IMSE and for all sample sizes
Atenolol was used with povidone iodine to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and povidone iodine in an aqueous medium. Optimum parameters was studied to increase the sensitivity development of method. Calibration graph was linear in the range of 2-19 mmol/L for cell A and 5-19 mmol/L for cell B. Limit of detection 146.4848 ng/55 µL and 2.6600 µg/200 µL respectively to cell A and cell B. Correlation coefficient (r) 0.9957 for cell A and 0.9974 for cell. Relative standard deviation (RSD %) was lower than 1%, (n=8) for the determination of
... Show More