Preferred Language
Articles
/
jih-440
Spectrophotometric Determinations of Sulfacetamide Following Simple Diazotization and Coupling with Chromotropic Acid
...Show More Authors

A simple, sensitive, accurate and economic spectrophotometric method has been developed for the determination of sulfacetamide (SFA) in pure form, synthetic sample and urine. The method is based on diazotization of primary amine group of sulfacetamide with sodium nitrite and hydrochloric acid followed by coupling with chromotropic acid in alkaline medium to obtain a stable orange colored chromogen which exhibit a maximum absorption (λmax) at   511.5 nm. Different variables affecting the completion of reaction have been carefully optimized following the classical univariate sequence and  modified simplex method (MSM). Under optimized conditions, Beer’s law obeyed in the concentration range of (0.5-         20.0 µg.ml-1) with molar absorptivity of 3.2186*104 L.mol-1.cm-1. The limit of detection was 0.054 µg.mL-1 and Sandell’s sensitivity value 7.8989 µg.cm-2. The proposed method was successfully applied to the determination of (SFA) in synthetic sample and urine.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Agricultural And Statistical Sciences
Effect of foliar spraying with gibberellic and humic acid on wheat growth
...Show More Authors

Scopus (9)
Scopus
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Study of Crack Effect on Frequency of Simple Supported Beam
...Show More Authors

In this research the natural frequency of a cracked simple supported beam (the crack is in many places and in different depths) is investigated analytically, experimentally and numerically by ANSYS program, and the results are compared. The beam is made of iron with dimensions of L*W*H= (0.84*0.02* 0.02m), and density = 7680kg/m3, E=200Gpa. A comparison made between analytical results from ANSYS with experimental results, where the biggest error percentage is about (7.2 %) in crack position (42 cm) and (6 mm) depth. Between Rayleigh method with experimental results the biggest error percentage is about (6.4 %) for the same crack position and depth. From the error percentages it could be concluded that the Rayleigh method gives

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
With Solvent Extraction Method, and via new Organic Reagent 2-(Benzo thiazolyl azo)-4,5- Diphenyl Imidazole for Spectrophotometric Determination of Copper (II) in different Samples
...Show More Authors

The new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and dis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Spectrophotometric Study of ?-Irradiated PM-355
...Show More Authors

The aim of the present work is concerned with the effect of ?-irradiation on PM-355 with absorbed dose of (30-160Mrad) range. This polymer is evaluated spectrophotometrically for use as high dose dosimeters. The absorption spectra of irradiated samples showed radiation induced absorption changes. There is an increment in absorption proportional with absorbed dose. This increment is attributed to interfaces traps which, are formed by irradiation. Calibration curve was drawn .The linear relation was found in calibration curve, and dosimeter range was determined from the linear part. The linearity in response curve suggested that PM-355 could be used as dosimeter within (30-160Mrad) rang. Energy gap shift was used as a second tool to determin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
GEOMETRY OPTIMIZATION OF COUPLING ALLIN -METFORMIN USING DFT/B3LYP MOLECULAR MODELLING TECHNIQUE: GEOMETRY OPTIMIZATION OF COUPLING ALLIN -METFORMIN USING DFT/B3LYP MOLECULAR MODELLING TECHNIQUE
...Show More Authors

This researchpaper includes the incorporation of Alliin at various energy levels and angles 

With Metformin using Gaussian 09 and Gaussian view 06. Two computers were used in this work. Samples were generated to draw, integrate, simulate and measure the value of the potential energy surface by means of which the lowest energy value was (-1227.408au). The best correlation compound was achieved between Alliin and Metformin through the low energy values where the best place for metformin to b

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Diclofenac sodium Using 2,4-dinitrophenylhydrazine in Pure Form and Pharmaceutical Preparations
...Show More Authors

A simple and sensitive spectrophotometric method is described for the determination of diclofenac sodium (DCL), in pure form and pharmaceutical formulations. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPH) and coupling of the oxidized product with DCL in alkaline medium to give intensively colored chromogen which exhibits maximum absorption (λmax) at 600 nm, and the concentration of DCL was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, modified simplex method (MSM) has been applied in optimization of the variables affecting the color producing reaction. Beer’s law is obeyed in the

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Global Pharma Technology
Spectrophotometric determination of loratadine in syrup and study viscosity conductivity and thermodynamic of binary mixed systems of surfactants with loratadine"
...Show More Authors

Scopus
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Isoptin (Verapamil Hydrochloride) in Pharmaceutical Preparations
...Show More Authors

Verapamil Hydrochloride (VH) has been determined spectrophotometrically by using Methyl Orange (MO).  In our previous researches MO was used for determination of Mexiletine Hydrochloride [1]. The method was based on complexation between (MO and VH).  After shaking and diluting the complex solution with D.W, the pH was adjusted with NaOH and HCl to pH 4. The colored complex formed between VH and the reagents were transferred into separating funnels and extracted using 4.5 ml CH2Cl2 and were shaken for (4 minutes).  The extracted organic layer was used for the preparation of the calibration curves for spectrophotometric measurements of VH at 437nm.  The blanks were carried out in exactly the same way throughout the whol

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Lower Ureteral Obstruction and Leakage in the First Month Following Renal Transplantation
...Show More Authors

Background: Transplantation has revolutionized
treatment of end- stage renal disease (ESRD) by proving
more cost effective than hemodialysis, with a lower
morbidity and improved quality of life.
Objective: To evaluate the development of these
complications in the first month postoperatively and
correlate their development to the type of donation
whether related or unrelated.
Methods: Fifty (50) patients aged (15-62) years, with a
mean age (34.46 ± 12.4 SD) years with (ESRD), who
underwent renal transplantation from September 2000 to
October 2002, were followed-up for one month
postoperatively clinically and by assessment of renal
function tests, sonographic and Doppler examinations.
Ureteral obs

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Technical Research And Applications
SYNTHESIS OF DRUG CARRIER POLYACRYLIC ACID WITH SPACER GROUP
...Show More Authors

Preview PDF