The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -Naphthalene, Acenaphthylene, Acenaphthene, Fluorene, Phenanthrene, Anthracene, Fluoranthene, Benzo(g,h,i)perylene , Pyrene , Benzo(a)anthracene, chrysene Benzo(a)Pyrene,Benzo(b)fluoranthene, Benzo(k)Fluoranthen , Dibenzo(a,h)Anthracene, and Indeno(1,2,3-cd)pyrene
Aromatic hydrocarbons present in Iraqi national surface water were believed to be raised principally from combustion of various petroleum products, industrial processes and transport output and their precipitation on surface water.
Polycyclic aromatic hydrocarbons (PAHs) were included in the priority pollutant list due to their toxic and carcinogenic nature. The concern about water contamination and the consequent human exposure have encouraged the development of new methods for
PAHs detection and removal.
PAHs, the real contaminants of petroleum matter, were detected in selected sites along Tigris River within Baghdad City in summer and winter time, using Shimadzu high performance liquid chromatography (HPLC) system.
Analysi
In this study, the amounts of activity concentrations of naturally occurring in 10 soil samples of the Tigris river and surrounding areas collected from deferent city of Baghdad have been investigated. Tigris river is an important water source for irrigation and drinking in Iraq. This study was done during 2018 in Protection Center of the Iraqi Ministry of Health and Environment using a high purity germanium detector. The resolution of (HPGe) at 2keV and 30% efficiency. The results of soil sample obtained showed that the effective activity concentration of 40K are ranged from 181.4 Bq/kg in sample S6 to 286.4 Bq/kg in S7. For Raeq values are ranged from 6 Bq/m3 in sample S5 to 17 Bq/m3 in sample S3. The obtained data revealed that the me
... Show MoreA Factorial Study for separation anxiety in students, of Baghdad City
A study was carried out to determine the concentrations of trace metals in vegetables and fruits, which are locally available in the markets of Baghdad-samples of fourteen varieties of vegetables and fruits, belonging to Beta vulgaris, Brassica rapa, Daucus carota, Allium cepa, Eurica sativa, Malva silvestris, Coriandrum Sativum, Trigonella Foenum craecum, Anethum graveolens, Barassica oleracea, Phaseolus vulgaris, citrus reticulata, Py rus malus, and Punica granatum. Analysis for Cd,Pb, Mn, Fe, Co, Ni, Cu and Zn were determined by flame atomic absorption sp ectrophotometry. The results indicated that the Malva silvestris recorded the highest concentrations of Cd and Mn while Allium cepa showed the highest concentrations of Pb and Cu. But E
... Show MoreA study was carried out to determine the concentrations of trace metals in vegetables and fruits, which are locally available in the markets of Baghdad-samples of fourteen varieties of vegetables and fruits, belonging to Beta vulgaris, Brassica rapa, Daucus carota, Allium cepa, Eurica sativa, Malva silvestris, Coriandrum Sativum, Trigonella Foenum craecum, Anethum graveolens, Barassica oleracea, Phaseolus vulgaris, citrus reticulata, Pyrus malus, and Punica granatum. Analysis for Cd,Pb, Mn, Fe, Co, Ni, Cu and Zn were determined by flame atomic absorption spectrophotometry. The results indicated that the Malva silvestris recorded the highest concentrations of Cd and Mn while Allium cepa showed the highest concentrations of Pb and Cu. But
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreA rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5
... Show MoreDirect determination of trace metals Zn, Mn, Cu and Co were performed in serum
blood samples of two groups diabetic patient type 2 and non diabetes by ICP spectrometric
method. Results show the low levels of these elements Zn, Mn and Co while high level of Cu
detected compared with non diabetes according to these results good evidence can be made to
control these levels through a special diet containing these metals.
The concentration of radon gas in the samples for drinking water and wells in the same place from selected homes in which wells were built in the Hay-al-Bayaa region of Baghdad was measured, by using a CR-39 nuclear track detector. It turns out that the maximum value of the concentration of radon in drinking water was 3.83 Bq/L, and the lowest was 2.30 Bq/L. As for the estimation of radon gas concentration in well water samples, the highest value was 5.6 Bq/L, while the lowest one was 3.1 Bq/L. In order to assess the committed effective dose received by the public due to the inhalation of radon gas. The highest value of the annual effective dose in drinking water was recorded in Al-Bayaa region, which is equal to 14.30 μSv/y, while th
... Show More