Preferred Language
Articles
/
jih-351
Detect The Infected Medical Image Using Logic Gates
...Show More Authors

   This paper determined the difference between the first image of the natural and the second infected image by using logic gates. The proposed algorithm was applied in the first time with binary image, the second time in the gray image, and in the third time in the color image. At start of proposed algorithm the process  images by applying convolution to extended images with zero to obtain more vision and features then enhancements images by Edge detection filter (laplacion operator) and smoothing images by using mean filter ,In order to determine the change between the original image and the injury the logic gates applied specially X-OR gates . Applying the technique for tooth decay through this comparison can locate injury, this difference may be tooth decay or a broken bone , cancerous cells or infected gums, The X-OR gate is the best gates uses in this technique. Simulation program using visual basic has been in order to determine final results.
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Preparation and Identification of some new Pyrazolopyrin derivatives and their Polymerizations study
...Show More Authors

Preparation and Identification of some new Pyrazolopyrin derivatives and their Polymerizations study

View Publication Preview PDF
Crossref