Preferred Language
Articles
/
jih-344
Univariate and Multivariate Optimization of Spectrophotometric Determination of Europium (III) in Pure Form and Synthetic Sample
...Show More Authors

    Two different approaches, univariate and multivariate (simplex method), have been used to obtain the optimum conditions for the quantitative Spectrophotometric determination of Eu3+ using Solochrome violet RS (3-Hydroxy-4-(2-hydroxy phenyl azo) naphthalene -1sulfonic acid) (SVRS) as a chromogenic reagent. The investigation shows that Eu3+ ion forms a wine-red complex with SVRS in alkaline buffer solution having a maximum absorbance at 464 nm against reagent blank.       Calibration graphs obtained under univariate and simplex were found to be linear in the range of (0.30-8.0) µg/ml with detection limit 0.061µg/ml and molar absorptivity of 9877.66 L/mol.cm and (0.40-10.0)µg/ml with detection limit 0.055µg/ml and molar absorptivity of 10759.05 L/mol.cm respectively. The stoichiometric composition of the formed Eu-SVRS chelate complex is 1:4 (Metal:Ligand). Effect of the presence of some metal ions as interferences was studied and the method has been applied successfully to the determination of cited ion in synthetic sample.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Thu Jan 11 2024
Journal Name
Tropical Journal Of Pharmaceutical Research
Application of Taguchi orthogonal array in optimization of the synthesis and crystallinity of metal organic framework 5 (MOF 5)
...Show More Authors

Purpose: To use the L25 Taguchi orthogonal array for optimizing the three main solvothermal parameters that affect the synthesis of metal-organic frameworks-5 (MOF-5). Methods: The L25 Taguchi methodology was used to study various parameters that affect the degree of crystallinity (DOC) of MOF-5. The parameters comprised temperature of synthesis, duration of synthesis, and ratio of the solvent, N,N-dimethyl formamide (DMF) to reactants. For each parameter, the volume of DMF was varied while keeping the weight of reactants constant. The weights of 1,4-benzodicarboxylate (BDC) and Zn(NO3)2.6H2O used were 0.390 g and 2.166 g, respectively. For each parameter investigated, five different levels were used. The MOF-5 samples were synthesi

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Simultaneous Quantitative Determination of Ciprofloxacin and Hydrocortisone by H-Point Standard Addition Method
...Show More Authors

Ciprofloxacin (Cip) and hydrocortisone (Hyd) were simultaneously measured as hydrochloride and sodium succinate, respectively, using the H-point standard addition method (HPSAM). The approach can precisely identify Cip in the presence of Hyd with various analyte-to-interference ratios (5:5, 5:10, 10:5, 10:10) µg.mL-1, in mixed samples containing (1-5µg.ml-1) of Cip, at the wavelengths of (236 and 257) nm. In the same way, Hyd was analyzed in the presence of Cip in different analytes with an interference ratio of (5:5, 5:10, 10:5, 10:10) µg.mL-1, in mixed samples containing (1-5 µg.mL-1) of Hyd, at wavelengths of (266 and 278) nm. The satisfactory results show good reproducibility of the dev

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Optimization of Hole Cleaning In Iraqi Directional Oil Wells
...Show More Authors

Efficient cuttings transport and hole cleaning are very important factors for obtaining an effective drilling operation. In an inclined and horizontal drilling, hole cleaning issue is a common and complex problem.

   The scope of this research is to study the drilling parameters which affect hole cleaning in Iraqi directional wells through studying and analyzing some drilled wells ( vertical , directional (30 degree) , directional (60 degree) and horizontal ).An excel sheet is prepared to calculate carrying capacity index which represents an indicator for good hole cleaning in different sections. The study indicated through the field investigations, practical experiences and theoretical calculations tha

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 30 2024
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Optimization of Separator Size and Operating Pressure for Three-phase Separators in the West Qurna1 Oil Field
...Show More Authors

An optimization study was conducted to determine the optimal operating pressure for the oil and gas separation vessels in the West Qurna 1 oil field. The ASPEN HYSYS software was employed as an effective tool to analyze the optimal pressure for the second and third-stage separators while maintaining a constant operating pressure for the first stage. The analysis involved 10 cases for each separation stage, revealing that the operating pressure of 3.0 Kg/cm2 and 0.7 Kg/cm2 for the second and third stages, respectively, yielded the optimum oil recovery to the flow tank. These pressure set points were selected based on serval factors including API gravity, oil formation volume factor, and gas-oil ratio from the flow tank.    To impro

... Show More
Preview PDF
Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Optimization and Prediction of Process Parameters in SPIF that Affecting on Surface Quality Using Simulated Annealing Algorithm
...Show More Authors

Incremental sheet metal forming is a modern technique of sheet metal forming in which a uniform sheet is locally deformed during the progressive action of a forming tool. The tool movement is governed by a CNC milling machine. The tool locally deforms by this way the sheet with pure deformation stretching. In SPIF process, the research is concentrate on the development of predict models for estimate the product quality. Using simulated annealing algorithm (SAA), Surface quality in SPIF has been modeled. In the development of this predictive model, spindle speed, feed rate and step depth have been considered as model parameters. Maximum peak height (Rz) and Arithmetic mean surface roughness (Ra) are used as response parameter to assess th

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Aug 01 2018
Journal Name
International Journal Of Hydrogen Energy
Synergistic effects and optimization of photo-fermentative hydrogen production of Rhodobacter sphaeroides DSM 158
...Show More Authors

View Publication
Scopus (34)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Tue Apr 30 2024
Journal Name
Iraqi Journal Of Science
Assessment of Some Physiological, Immunological and Molecular Biomarkers in Sample of Iraqi Women Undergoing Caesarean Section and Normal Delivery
...Show More Authors

     Pregnancy and delivery are physiological conditions that are marked by abrupt alterations to hormones, immunological and molecular characters. The current study aimed to evaluate oxytocin (OT), prolactin (PRL), cortisol and insulin growth factor-2 (IGF-2) levels as physiological biomarkers; programmed cell death protein-1 (PD-1), programmed cell death ligand-1 (PD-L1),interleukin-6 (IL-6) as immunological biomarkers, and single nucleotide polymorphisms (SNPs; rs53576 and rs2254298) of oxytocin receptor gene OXTR as molecular factors in samples of Iraqi women undergoing caesarean section (CS) and normal delivery (ND). Blood samples were collected from 96 pregnant women at term with ages ranging between 16-43 years. Regarding

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jul 04 2022
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of agricultural insurance in the prevention of financing risks in the form of slam : "An Empirical Study on Shikan Insurance and Reinsurance Company
...Show More Authors

The aim of this research is to introduce agricultural insurance, to define financing in the form of salam and the role of agricultural insurance in the prevention of risks to agricultural finance operations in the form of salam by verifying the hypotheses through which to reach the results, including the imposition of risks for agricultural finance in the form of salam, The study of agricultural finance in the form of salm, the deductive approach to the development of the problem of research and hypotheses, and the inductive method to extrapolate the results through analysis and brother The researcher concluded that agricultural insurance works to bridge the risks facing agricultural finance in the form of the ladder in cases of

... Show More
View Publication Preview PDF
Publication Date
Wed May 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Study for Charge Transfer Complexes Between p- Chloranil with Anions of Amide, Azide and Cyanide
...Show More Authors

    The complexes of para-chloranil as electron acceptor and the anions of amide, azide and cyanide as electron donors in aqueous ethanol as a solvent, were studied spectrophotometrically .     The reactions lead to the formation of charge transfer complexes. The CT complexes were stable in excess acceptor concentration, while they were underwent another transformations in excess donors concentrations.   Stoichiometries were determined, the molecular ratio was determined by continuous variation method (Job method) and is was  1:1 (donor: acceptor).   The maximum wavelength (λ max.), the energy (hÏ…CT), ionization potential (Ip) and activation energy (w ) of excited state f

... Show More
View Publication Preview PDF