Evaporation from water bodies is important and considered a major problem in dry and semi-dry regions, in this research the evaporation has been analyzed from two approaches: engineeringly and statistically. The engineering approach deals with the calculation of evaporation rates of Mosul Dam Lake. Three methods were used: pan evaporation class A, the combined and the mass-transfer. It was found that the values obtained by pan evaporation class A method was the highest among the other, while the mass transfer method achieved the lowest results. The evaporation rates during the year ranged according to the first method (0.9–5.5) mm/day, second (0.7–11.5) mm/day and the last method (1.0039×106) m3/year, which represents 9% of the highest storage in the Mosul Dam Lake.The statistical approach, the values of the evaporation occurring in Mosul Dam Lake were forecasted for the 2016-2017 rainy period, and 255 observations were used to find two forecasting models that were constructed using the simple exponential smoothing and Holt methods, then compare the results with the actual values of evaporation starting from (256 – 265) depending on MSE ,the Holt method gave less value to MSE than the simple exponential smoothing method, as its value was 0.421 versus 2.576. Matlab (14a) and R (3.2.1) were used in the statistical analysis.
Abstract
The research Compared two methods for estimating fourparametersof the compound exponential Weibull - Poisson distribution which are the maximum likelihood method and the Downhill Simplex algorithm. Depending on two data cases, the first one assumed the original data (Non-polluting), while the second one assumeddata contamination. Simulation experimentswere conducted for different sample sizes and initial values of parameters and under different levels of contamination. Downhill Simplex algorithm was found to be the best method for in the estimation of the parameters, the probability function and the reliability function of the compound distribution in cases of natural and contaminateddata.
... Show More
Objective: To assess knowledge and skills level regarding oxygen administration methods at p
ediatric teaching hospitals in Mosul City.
Methodology: A descriptive study was applied at pediatric teaching hospitals (Al-Kansaa, and Ibn Al-Atheer) in Mosul City from 8 of October / 2018 till 29 of May / 2019. The selection of the sample was non- probability (Purposive). This sample involved of (52) nurses. The questionnaire was constructed which consists of three parts and provided for nurses. The questionnaire validity was carried out through a panel of experts. To evaluate statistically the reliability of instruments, the pilot study was applied through period from 20– till –31 of January / 2019. Non-randomly (6) nurses from Ibn S
Determining the actual amounts of active ingredients in various pharmaceutical commercial forms is still receiving a lot of attention. Two flow injection analysis (FIA) methods were suggested for determination of mesalazine (MES) in pharmaceutical forms. Normal and reverse FIA systems (nFIA and rFIA) combined with UV-Vis spectrophotometric technique were used for the analysis. The methods involved using two mods of FIA systems for measuring a colored product result from coupling of MES with 2,2'-dihydroxybiphenyl after oxidized with sodium periodate in alkaline medium. The absorbance of the red colored dye was measured at maximum wavelength of 500 nm. The calibration graphs for MES were linear in the ranges 2.5-200 and 0.5-60 µg/mL with
... Show MoreConservative pipes conveying fluid such as pinned-pinned (p-p), clamped–pinned (c-p) pipes and clamped-clamped (c-c) lose their stability by buckling at certain critical fluid velocities. In order to experimentally evaluate these velocities, high flow-rate pumps that demand complicated fluid circuits must be used.
This paper studies a new experimental approach based on estimating the critical velocities from the measurement of several fundamental natural frequencies .In this approach low flow-rate pumps and simple fluid circuit can be used.
Experiments were carried out on two pipe models at three different boundary conditions. The results showed that the present approach is more accurate for est
... Show MoreIn this paper, we derived an estimator of reliability function for Laplace distribution with two parameters using Bayes method with square error loss function, Jeffery’s formula and conditional probability random variable of observation. The main objective of this study is to find the efficiency of the derived Bayesian estimator compared to the maximum likelihood of this function and moment method using simulation technique by Monte Carlo method under different Laplace distribution parameters and sample sizes. The consequences have shown that Bayes estimator has been more efficient than the maximum likelihood estimator and moment estimator in all samples sizes
A non-parametric kernel method with Bootstrap technology was used to estimate the confidence intervals of the system failure function of the log-normal distribution trace data. These are the times of failure of the machines of the spinning department of the weaving company in Wasit Governorate. Estimating the failure function in a parametric way represented by the method of the maximum likelihood estimator (MLE). The comparison between the parametric and non-parametric methods was done by using the average of Squares Error (MES) criterion. It has been noted the efficiency of the nonparametric methods based on Bootstrap compared to the parametric method. It was also noted that the curve estimation is more realistic and appropriate for the re
... Show More