Peripheral neuropathy represents one of the common diabetic complications in patients with diabetes mellitus type 2 (DMT2). Peripheral neuropathy affects the feet, legs, hands, and arms. It was found that one-third to one-half of diabetics have peripheral neuropathy. The current study aimed to evaluate the level of visfatin in diabetic patient groups with or without peripheral neuropathy in comparison with healthy subjects to knowledge whether visfatin can be applied as a predictor factor for this type of disease complication. The study included 120 males and females ranging in age from 40 to 97 years old. (40 patients with type 2 diabetes, 40 patients with diabetic peripheral neuropathy, and 40 healthy people served as the control group.) All of the diabetes patients had a verified diagnosis (type 2). During the period from October 2021 to December 2021, the patients were assessed at the National Diabetes Center, Al-Mustansiriya University in Baghdad. Visfatin levels were tested using the ELISA technique, and HbA1c was assessed using Cobas C111. In patients, HbA1C levels are significantly higher (p≤0.05) than in controls. Males and females with DPN and DM have greater Visfatin mean values than the control group. Visfatin levels are strong indications for early diagnosis of diabetic neuropathy in both males and females, according to the current study.
Background: Colonic cancer is a very common disease world-wide being fourth most common cancer characterized by abnormal proliferation of the inner wall of colon then taking full colon wall thickness then spreading to surrounding lymph nodes and tissues and finally distant metastasis. It is one of most complicated diseases with debilitating symptoms which becomes more sever , prominent and specific with advancing stage with high percent of fatality and relatively short survival if diagnosed late or if left untreated.Objective: To evaluate the efficacy of serum CEA & sAPRIL levels in the diagnosis and screening of colon cancer and their validity for this.Patients and methods: This study was applied on 35 patients with colonic can
... Show MoreRheumatoid arthritis is a chronic systemic inflammatory disease. Inflammation leads to joint damage and increases the risk of cardiovascular diseases. Neutrophil lymphocyte ratio (NLR) is a measure of inflammation in many diseases. Therefore, we aimed to evaluate the usefulness of NLR to detect inflammation in RA, and its correlation to RA disease activity indices and some hematological parameters. A cross-sectional study involving 24 patients with active rheumatoid arthritis (RA) who are using MTX participated in this study. All patients were clinically evaluated using disease activity score of 28 joints (DAS28) and simplified disease activity index (SDAI), whereas functional disability was assessed by health assessment questionnaire di
... Show MoreBackground :Atherosclerosis is the most
frequent underlying cause of ischemic heart
disease and a major cause of death all over the
world. This study was carried out to analyze and
compare the angiographic findings in patients
with diabetes mellitus versus non diabetics with
coronary heart disease , and to correlate these
findings with some risk factors for coronary
heart disease.
Methods: A total of 100 patients were studied,
50 with diabetes mellitus, and 50 non diabetics.
This study was carried out at Al-Sadr teaching
hospital in Basrah, Southern Iraq during the
period April 2009- September 2009. All patients
were known to have coronary heart disease. Risk
factors for coronary heart disease
This study objective is to identify the visual pollution in Karrada district main streets as an example of main streets in Baghdad, the public opinion about each pollutants, solutions to reduce and eliminate the pollution were suggested as well. In order to accomplish this objective different methods were used, 16 pollutants were selected, pictures of each pollutants were taken and a questioner were distributed randomly for 270 people to evaluate the public opinion with statistical methods. Garbage, their disposal and storage areas took the first two places as the highest offensive pollutants. The people showed that they find long lines of vehicles, debris and generators appearance ranked third, fourth and fifth respectively .This resear
... Show MoreA rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea
... Show MoreSimple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac
... Show MoreThis approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo
... Show MoreA simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations
... Show MoreObjective: To determine the quality assurance for maternal and child health care services in Baghdad City.
Methodology: A descriptive study is conducted throughout the period of November 28th 2008 to October 10th
2009. A simple random sample of (349) is selected through the use of probability sampling approach. The study
sample was divided into four groups which include (220) consumers, (35) medical staff, (72) nursing staff and (22)
organization structure (primary health care centers). Data were collected through the use of assessment tools. It was
comprised of four questionnaires and overall items included in these questionnaires are (116) items. The study
included assessment of organization structure. Data were colle