Efficiency Evaluation of Solar Concentrator without Tracking System Type of Compound Parabolic Concentrator (CPC)
...Show More Authors

      It is useful to analyze any optical system theoretically before proceeding with its design in order to ensure the effectiveness of the design through computer simulations that are important and useful in designs for the ability to predict the performance of solar concentrator under any conditions.  For this design, non-sequential ray tracing mode wasused in the Zimax program with a light source that simulated solar radiation.  The purpose of the design of a compound parabolic concentrator (CPC) is to take advantage of the solar radiation that falls on it without the need for an efficiently tracked system within certain limits of the angle of solar radiation fall known as the acceptance angle.  That is, obtaining the largest possible number of rays received inside the CPC through reflections in the inner walls of it, which give a large amount of thermal energy to the surface of the recipient, which in turn gets this energy to be used to create electrical energy. The efficiency of receiving reflected solar radiation in this type of concentrator is great compared to other solar concentrators.

Simulated design of solar reflector concentrator has been presented. The concentrator is a type of compound parabolic concentrator (CPC) involved of internal reflector surface (Hollow and within Poly methyl methacrylate (PMMA) polymer material) without tracking system. CPC has the property to overcome problems result from variation of incidence angle of the sun during daytime. Because the tracking system expensive and has technical problems. The efficiency of CPC has been obtained by using Zemax optical design program, for different designs has concentration ratio(c=1,2,3,4,5). That is, the ratio of the output aperture to the input aperture. Taking into account the angle of acceptance that plays a major role in the form of design and its efficiency the results are shown when designing the model with radial aperture of (50mm) and length of (500mm).The design of concentrations ratio is depends on the acceptance angle.

c=5 at normal incident angle (ÆŸ=0). And it is almost similar if the material is used PMMA within CPC, and degradation of efficiency with increasing the incidence angle.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
udyStudyStudyStudyStudy of of the Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extractthe Efficiency of Extract
...Show More Authors

The aim of current study is estimate the ability of low cost adsorbents, which consist of extracted silica from rice husk ash in treatment of Industrial waste water that contains heavy metals (Cd, Co and Pb) with other pollutants by fixed filters technique with determine the best method for that, and study the effect of a number of variables and parameters. This study involved one waste water samples were collected from. State battery manufacturing company (SBMC) (before treatment unit) at 5th and 22th, of the January 2015. Adsorption tests showed that all tested adsorbent materials had a significant heavy metal removal efficiency. pH values showed a significant impact on adsorption process, but best removal efficiency occurred at pH 4.5

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Improvement the Action Efficiency of Microwave Vacuum Tube Type GI-19B by Activation its Intersurfaces
...Show More Authors

In this research an improvement of the efficiency  of vacuum microwave  tube  type      Gl-19B     had  been  done  by activation    of internal surfaces   using two specific  procedures  which can qualify  the tubes to be reused again.

The first method  was the reevacuuated  and heating treatment.

The second  method wa:s the glow discharge  method which  used ro

clean the electrodes and improve the vacuum to about!o·8 mbar.

In order   to study  the  using of  both processes   together,  Copper

samples  heate

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al- Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regressio

... Show More
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression ana

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of concentrations ratios of NiO on the efficiency of solar cell for (CdO)1-x(NiO)x thin films
...Show More Authors

CdO:NiO/Si solar cell film was fabricated via deposition of CdO:NiO in different concentrations 1%, 3%, and 5% for NiO thin films in R.T and 723K, on n-type silicon substrate with approximately 200 nm thickness using pulse laser deposition. CdO:NiO/n-Si solar cell photovoltaic properties were examined under 60 mW/cm2 intensity illumination. The highest efficiency of the solar cell is 2.4% when the NiO concentration is 0.05 at 723K.

View Publication Preview PDF
Crossref
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
Evaluation Efficiency of Wind Turbines for Barjisiah (South of Iraq) Wind Plant
...Show More Authors

The main objective of the paper is to study the possibility of erecting 2 MW wind turbine in the south of Iraq (Barjisiah site) by utilizing WAsP model. Wind potential and output predicted the power of WT at a supposed site was calculated. The results for proposed WT showed the WT has a weak performance due to its high capacity and low potential of wind speeds at this site. So, the WT will provide power for a limited time during the year due to its operating at the zone under the rated wind speed.

View Publication Preview PDF
Publication Date
Wed Jan 25 2023
Journal Name
Molecular Simulation
Engineering promising A-π-D type molecules for efficient organic-based material solar cells
...Show More Authors

Within this work, to promote the efficiency of organic-based solar cells, a series of novel A-π-D type small molecules were scrutinised. The acceptors which we designed had a moiety of N, N-dimethylaniline as the donor and catechol moiety as the acceptor linked through various conjugated π-linkers. We performed DFT (B3LYP) as well as TD-DFT (CAM-B3LYP) computations using 6-31G (d,p) for scrutinising the impact of various π-linkers upon optoelectronic characteristics, stability, and rate of charge transport. In comparison with the reference molecule, various π-linkers led to a smaller HOMO–LUMO energy gap. Compared to the reference molecule, there was a considerable red shift in the molecules under study (A1–A4). Therefore, based on

... Show More
View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Nov 19 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Estimation of pentraxin-3(PTX3)in Rheumatoid arthritis males patients with (with and without) type II diabetes mellitus in Iraq
...Show More Authors

Rheumatoid arthritis is a chronic inflammatory autoimmune disease its etiology is  unknown . The classical autoimmune diseases, have adaptive immune genetic associations with autoantibodies and major histocompatibility complex(MHC) class II such as rheumatoid arthritis (RA), diabetes mellitus type two (DM II). Serum of99 males suffering from RA without DMII as group (G1), 45 males suffering from RA with DM II as group (G2) and 40 healthy males as group (G3) were enrolled in this study to estimation of alkaline phosphates (ALP),C-reactive protein(CRP) and Pentraxin-3(PTX). Results showed a highly significant increase in PTX3 levels in G1 and G2 compared to G3 and a significant decrease in G1comparing to G2. Results also revealed a si

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Modeling and Simulation of Thermal Performance of Solar-Assisted Air Conditioning System under Iraq Climate
...Show More Authors

In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c

... Show More
View Publication Preview PDF