A sensitive and environmentally benign spectrometric method was developed for quantifying Meprobamate (MEP). The analyzed MEP was derivatized into a colored complex and determined spectrometrically. The colorimetric analytical parameters were optimized and validated. Low limit of detection (LOD) was achieved down to 1.88×10-6 mol/l while the limit of quantification (LOQ) was extended over the range of 1.97×10-6 - 1.35×10-3 mol/l. The high precision has been denoted by the 1.54% value of the coefficient of variation. The recovery was 96.07%, while the RSD (n=3) was 1.05 - 1.19%. The apparent molar absorptivity (Æ) obtained within 1154.7 - 1691.9 L.mol-1.cm-1. The outcomes have signified the high sensitivity of the technique. Furthermore, the avoidance of any traditional sample preparation steps prior to the analysis make the method an excellent environmental approach. There were no analytical interferences with the common composites. The method has been successfully verified for the quantification of MEP content in bulk pharmaceutical matrix and can be applied to determine other environmentally toxic carbamates.
Been using a pv system program to determine the solar window for Baghdad city . the solar window for any location can be determine by deviating left and right from the geographical south as well as deviation according to the amount of tilt angle with the horizon for fixed panel so that will not change the average of solar radiation incident over the whole year and this lead to help in the process of installation of fixed solar panel without any effect on annual output .the range of solar window for Baghdad city between two angles ( -8 - +8 ) degrees left to right of the geographical south and tilt angle that allowed for the horizon range between angles (21- 30) degrees so that the amount of solar radiation that falling on the solar pan
... Show MoreThe determination of manganese (II) using flow injection analysis with chemiluminescence detection was investigated. Mn2+ in sample solutions injected into a carrier stream of sodium bismuthate (NaBiO3) were oxidised to form MnO4- ions which were capable of producing luminescence after reaction with luminol/KOH in a flow cell. The linear range of the system is from 20 to 80 mg/L with a detection limit 8 mg/L. The proposed system is suitable for determination of Mn2+ in steel alloys after dissolution, filtration and dilution at a rate of approximately 60 samples per hour with a relative standard deviation (RSD)1.2%. Statistical comparison between the proposed system and standard spectrophotometric method revealed that there is no signific
... Show MoreStable isotope (?18O, ?D) values were determined along with the chemical compositions at 10 different locations along the Tigris river between Baghdad-Ammara cities of Iraq. The physico-chemical parameters and isotopic data were measured. The sampling site represents 34 % of total Tigris river in the republic of Iraq. The systematically increased in values of stable isotope as move from the downstream of the river and the most significantly appears at Kut lake. This increase occurs as a result of several factors, viz. (a) evaporation occurs low water level in the river and its tributaries, and (b) return flow water to the river from irrigation water in groundwater systems. The change in ion distribution and in the isotopic values related di
... Show MoreA rapid and sensitive method for the determination of amoxicillin trihydrate (AMXT) based on the diazo-coupling reaction was studied. Sulphanilic acid diazotizes with nitrite ion in acidic medium to produce a water soluble, colorless diazonium ion, which subsequently coupled with AMXT to form a colored azo dye in the alkaline medium, having maximum absorption at 455 nm. The calibration graph showed that Beer's law is obeyed over the concentration range of 0.3 – 30.0 μg/mL of AMXT, with the detection limit of 0.15 μg/mL and molar absorptivity was 2.3 × 104 L/mol.cm. The accuracy and the precision were acceptable depending upon the values of error percentage and relative standard deviation. The influence of common interfer
... Show MoreA rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5
... Show MoreA rapid, sensitive and selective spectrophotometric method was developed for determination of sulfathiazole (STHZ) in aqueous solution. The method is based on the oxidative coupling reaction with 2,4-dinitrophenylhydrazine (2,4-DNPH) in a basic medium (pH 10.9) in the presence of potassium periodate to produce an intense orange colour, soluble in water , stable product and absorbs at 492 nm. Beer's law was in the linear range 2.0-28.0 μg/ml of sulfathiazole, the molar absorptivity, Sandellʼs sensitivity index and detection limit were 1.1437 ×104 liter. mol-1.cm-1,0.0223 μg.cm-2 and 0.1274 μg/ml respectively. The RSD value was 0.75 - 1.12 % depending on the concentration. This method was applied successfu
... Show MoreThis researd exhibit's a method to determine the change in Gibbs function,(enthai py,entropy. and specific heat capacity) tor monovariant heterogeneous equilibria .The thermodynamical quan.tities were obtained jndirectly with m the measurment of temperature dependent on eql,lilibrium system.
A new Spectrophotometric method, is for individual and simultaneous determination of Ciprofloxacin hydrochloride(CIP) and Mebeverin hydrochloride(MEB) by the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of CIP and MEB in concentration range of (4-28µg/mL) by measuring the amplitude of peak- to- base line and the area under peak at selected spectrum intervals. The methods showed a reasonable precision and accuracy and have been applied to determine CIP and MEB in four different pharmaceutical preparations.
A simple, rapid, accurate and sensitive spectrophotometric method has been developed for the determing carbamate pesticides in both pure and water samples. The method is appropriate for the determination of carbofuran in the presence of other ingredients that are usually available in dosage forms. The effect of organic solvents on the spectrophotometric properties of the azo dye and the structure of the resulting product have also been worked out and it is found to be 1:1 benzidine :carbofuran. The method can be successfully applied to determination of carbofuran in water samples. The method is based on diazotization of Benzidine (4, 4 – diamino biphenyl) with sodium nitrite and hydrochloric acid followed by coupling with carbofuran
... Show More