Preferred Language
Articles
/
jih-2282
Determination of Ibuprofen in Pharmaceutical Formulations Using Differential Pulse Polarography
...Show More Authors

     A reliable differential pulse polarographic (DPP) method has been developed and applied for the determination of ibuprofen IBU in dosage form with dropping mercury electrode (DME) versus Ag/AgCl. The best peak was found at cathodic peak of -1.18 V in phosphate buffer at pH=4 and 0.025M of KNO3 as supporting electrolyte. In order to obtaine the highest sensitivity, instrumental and experimental parameters were examined including the type and concentration of supporting electrolyte, pH of buffer solution, pulse amplitude and voltage step time. Diffusion current showed a direct linear relationship to ibuprofen concentration in the range of (5 – 30) μg. mL-1 (2.43× 10-5 – 1.45 × 10-4 mol·L–1) with correlation coefficient r= 0.9999, detection limit (S/N = 3) =3.40 μg. mL-1 (1.65 × 10-5 mol·L–1) and the value of precision in terms of relative standard deviation  RSD%, ranged between 0.374-0.5176 %. The established DPP method offers an excellent analytical figure of merits as well as its successful applicability to examine two commercial drug forms (tablet and suspension) for the determination of ibuprofen.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Food Chemistry
Micro-solid phase extraction with liquid chromatography–tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage
...Show More Authors

A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1

... Show More
View Publication
Scopus (61)
Crossref (61)
Scopus Clarivate Crossref
Publication Date
Sun Jun 23 2019
Journal Name
Arma
Safe Mud Weight Window Determination: A Case Study from Southern Iraq
...Show More Authors

ABSTRACT:. The Lower Cretaceous Zubair formation is comprised of sandstones intercalated with shale sequences. The main challenges that were encountered while drilling into this formation included severe wellbore instability-related issues across the weaker formations overlaying the reservoir section (pay zone). These issues have a significant impact on well costs and timeline. In this paper, a comprehensive geomechanical study was carried out to understand the causes of the wellbore failure and to improve drilling design and drilling performance on further development wells in the field. Failure criteria known as Mogi-Coulomb was used to determine an operating mud weight window required for safe drilling. The accuracy of the geomechanical

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Evaluation of the Organic-Pollution Based on the Determination of some Polycyclic Aromatic Hydrocarbons(PAHs) in Tigris River Water in 2012 at Baghdad City , Iraq
...Show More Authors

This study aims to predict the organic pollution produced from the presence of some polycyclic aromatic hydrocarbons (PAHs) and determination it's concentrations (µg/L , ppb) in Tigris river water by a collection twenty-seven water samples from a selected three stations with nine sampling sites and three depths of water (5 cm , 2 m and 4 m) each site for 4.6 km distance of a geographic studied area which is located between the ( Al-Senak and AL-Sarrafiah bridges ) at Baghdad city – Iraq on May, 2012. The geographic location was determined with a Global Positioning System (GPS) and Geographic Information System (GIS) software program. The concentrations of fourteen components (PAHs) were performed using the reverse phase

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Baghdad Science Journal
Determination of Similarity and Variance in Energy and Depositional Environment, the Difference in Diagenesis and the Variance in the Petrophysical Properties of Reservoir Rocks in Zubair Formation , South Iraq
...Show More Authors

Records of two regionalized variables were processed for each of porosity and permeability of reservoir rocks in Zubair Formation (Zb-109) south Iraq as an indication of the most important reservoir property which is the homogeneity , considering their important results in criterion most needed for primary and enhanced oil reservoir .Z and F tests that were calculated for the two above mentioned properties of pair units of Zubair Formation have shown the difference in depositional energy and different diagenesis between units IL and AB , DJ and AB , and the similarity in grains size , sorting degree , depositional environment and pressure gradients between IL and AB units , LS and IL units ; also the difference in the properties above betw

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Determination of Cefalexin by Direct (UV- Vis) Spectrophotometer and Indirect(Flame Atomic Absorption) Technique
...Show More Authors

         A new method for the determination of the drug cefalexin in some Pharmaceuticals using (UV-Vis) and  indirect Flame Atomic Absorption Spectrophotometer (FAAS) , Fe III should forms a chelating complex with cefalexin (CEX –Fe III) at pH (1-8) and the best pH for the formation of (CEX –Fe III) chelating complex was (2) .The complex extracted with Methanol  and  Dimethy-Sulphoxide .The mole-ratio method has been used to determine the structure of chelate (CEX - Fe III) and found to be 2:1 LM ( Ligand : Metal.) .

Keywords : Cefalexin , chelating complex.

View Publication Preview PDF
Crossref
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Removal Interferences with Spectrophotometric Study for the Determination of Chromium, Vanadium and Their Application
...Show More Authors

  The species of Cr (III), Cr (VI) in biological samples and V(IV), V(V) in foods & plants samples were determined by spectrophotometric methods. Integrated spectral studies of complexes [Cr (III, VI)-DPC], [Cr (VI)-bipy], [VO-SH], [V (V)-8-HQ] which included a study of the optimum conditions for the complexes formation by the investigation of the chemical and physical variables affecting each complex formation, the nature of complexes, the preparation of calibration curves of the complexes and treated the resulted data by modern statistical methods and study the interfering species. Interferences were removed to explain the reactions thermodynamically by determining Eï‚°cell, Keq. and ∆G values and includes a study of

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Sulfamethoxazole with P-N,N-dimethyl amino benzaldehyde as Condensation Reaction
...Show More Authors

Sulfamethoxazole (SMX) was added to P-N,N-dimethyl amino benzaldehyde (PDAB) by condensation reaction in acidic medium to form, a yellow colored dye compound which exhibits maximum absorption (λmax) at 450.5 nm. The concentration of (SMX) was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, design of experiment method has been applied in optimization of the variables affecting the color producing reaction.    Beer’s law obeyed in the concentration range of 0.1-10 μg.mL-1 with molar absorptivity of 5.7950×104  L.mol-1.cm-1. The limit of detection and Sandell's sensitivity value were 0.078 μ

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Solvent Extraction of Phenolic Compounds and Determination Total Phenolic Content from Teucrium Polium Plant
...Show More Authors

       A direct solvent extraction was used for the determination of phenolic compounds from Teucrium polium . Methanol, ethanol, iso-propanol, butanol and D.W  were used as an extractants and study  the affecting extraction factors including : the type and solvent concentration, temperature, extraction time and number of batch extraction, by  using Folin-ciocalteu method to determine the Total Phenolic Content (TPC) and measurement of the absorbance at λmax 765nm. The accuracy and precision of this method were determined by preparing laboratory samples of Gallic acid , the results showed relative errors ranging from ±0.5 – 1.49 % and the standard deviation equal to 1.2

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Determination of Skip Entry Trajectories for Space Vehicles at Circular and Super Circular Speeds
...Show More Authors

The study of entry and reentry dynamics for space vehicles is very important, particularly for manned vehicles and vehicles which is carry important devices and which can be used again. There are three types for entry dynamic, ballistics entry, glide entry and skip entry. The skip entry is used in this work for describing entry dynamics and determining trajectory. The inertia coordinate system is used to derive equations of motion and determines initial condition for skip entry. The velocity and drag force for entry vehicle, where generate it during entry into earth’s atmosphere are calculated in this work. Also the deceleration during descending and determining entry angles, velocities ratio and altitude ratio have been studied. The c

... Show More
View Publication Preview PDF