The polymeric hydrogels composed of poly vinyl alcohol (m.wt 72000) and glutaraldehyde(5%,8% and 10%) , have been thermally prepared for the purpose of studying their swelling and drug release behavior . The swelling ratio was measured for all the hydrogel samples at 37°C, in three different media pH (1.2, 4.7 and 6.8) as a function of time. The results show that the maximum swelling ratios were arranged as follows :pH =6.8 > pH =4.7 > pH =1.2 hydrogels cross linked PVA showed a typical pH responsive behavior such as high pH has maximum swelling while low pH shows minimum swelling.
The idea of using slender Reinforced Concrete (RC) columns with cross-shaped (+-shaped) instead of columns with square-shaped was discussed in this paper. The use of +-shaped columns provides many architectural and structural advantages, such as avoiding prominent columns edges and improved the structural response of member. Therefore, this study explores the structural response of slender +-shaped columns experimentally and numerically by nonlinear finite element analysis using Abaqus simulation tools. The results showed an excellent convergence in strength between numerical and test results with an average standard deviation of 0.05 and 0.07. Besides that, the use of +-shaped column
This paper proposed a theoretical treatment to study underwater wireless optical communications (UWOC) system with different modulation schemes by multiple input-multiple output (MIMO) technology in coastal water. MIMO technology provides high-speed data rates with longer distance link. This technique employed to assess the system by BER, Q. factor and data rate under coastal water types. The reliability of the system is examined by the techniques of 1Tx/1Rx, 2Tx/2Rx, 3Tx/3Rx and 4Tx/4Rx. The results shows the proposed technique by MIMO can get the better performance compared with the other techniques in terms of BER. Theoretical results were obtained to compare between PIN and APD
Objective: To evaluate the functional outcome of percutaneous cross two K wires fixation for Gartland types II and III fractures of humerus. Methodology: This prospective study included80 patients with supracondylar humeral fracture, who underwent closed reduction and fixation by two crossed Kirschner wires. We included children with age < 15 years with closed fractures with Gartland types II and III, while the patient with vascular injury, open, irreducible fractures were excluded. The patients were following up for 6 months and assessed functionally by Flynn’s criteria. Results: The mean age of patients was 8.1 years. Trauma while child playing was the main mechanism of injury in 43 (59.8%) children and 46 (57.5%) fractures were of the
... Show MoreTridentate Schiff base ligand L2 and its complexes with nickel(II), cobalt (II), copper (II), manganese (II) and mercury (II) ions have been synthesized by the condensation of 4Aminoantipyrine, Benzoin, then the ligand (L1) and 3-amino benzoic acid. The ligand and its complexes were described by 1H-&13C-NMR, UV-visible, FT-IR, (only ligand), molar conductance elemental, analysis and magnetic susceptibility, calculations. It has been set that the ligand acts as (N, N, O) neutral tridentate forming chelates with stoichimetry (metal: ligand) (1:1). all metal complexes is suggested Octahedral configuration. Most of the prepared compounds show antibacterial activity to (Staphylococcus aureus),(Escherichia coli), (Bacillussubtilis) and (Ps
... Show MoreBraces in straight bridge systems improve the lateral-torsional buckling resistance of the girders by reducing the unbraced length, while in horizontally curved and skew bridges, the braces are primary structural elements for controlling deformations by engaging adjacent girders to act as a system to resist the potentially large forces and torques caused by the curved or skewed geometry of the bridge. The cross-frames are usually designed as torsional braces, which increase the overall strength and stiffness of the individual girders by creating a girder system that translates and rotates as a unit along the bracing lines. However, when they transmit the truck’s live load forces, they can produce fatigue cracks at their connection
... Show MoreThe Sliding Mode Control (SMC) has been among powerful control techniques increasingly. Much attention is paid to both theoretical and practical aspects of disciplines due to their distinctive characteristics such as insensitivity to bounded matched uncertainties, reduction of the order of sliding equations of motion, decoupling mechanical systems design. In the current study, two-link robot performance in the Classical SMC is enhanced via Adaptive Sliding Mode Controller (ASMC) despite uncertainty, external disturbance, and coulomb friction. The key idea is abstracted as follows: switching gains are depressed to the low allowable values, resulting in decreased chattering motion and control's efforts of the two-link robo
... Show MoreBackground: Pain, swelling and trismus are the main minor complications encountered after surgical extraction of impacted third molars, minimizing these postoperative complications is the center of many studies, one proposed method is the prophylactic administration of corticosteroids, the aim of this study is to evaluate the effect of prophylactic Dexamethasone administration on facial swelling and trismus after surgical extraction of impacted third molars. Materials and methods: 20 patients were included in this study, they were randomly divided into 2 groups of 10 patients each; a study group in which patients were given 8 mg. Dexamethasone 1 hour before surgical extraction of impacted third molar and 4 mg. 6 hours postoperatively, and a
... Show More