Preferred Language
Articles
/
jih-2126
Investigation in the Effect of Applied Voltage and Working Pressure on Some Plasma Parameters in the Positive Column of Dc Glow Discharge
...Show More Authors

     Comsol multiphysics software is established to make a simulation that is comparable with experimental device. by utilizing comsol, the positive column domain of direct-current glow discharge with argon is considered for both of different applied voltage and working gas pressure. The calculations are exhibited by using a precise collision cross sections and Townsend coefficients for the argon. The impacts of voltage and pressure on the Debye length, number of particles in Debye sphere and plasma frequency are calculated and graphically delineated. With this regard to the dependence of plasma parameters on the applied voltage and pressure, some of them are found to be compatible with the experimental results, while others are not. For example, the calculations of the COMSOL shows that the electron temperature is not always decreasing with the increase in the applied voltage, and the Debye length does not give a linearly decreasing relationship but rather an exponentially decreasing relationship. Also, the calculations do not reproduce and match the experimental results for the dependence electron density on working pressure at various potentials.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Effect of magnetic water in the some parameters of growth & activity of some enzymes in the ( Raphanus raphanistrum L.) Plant
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Journal Of Science
The Effect of Variance Discharge on the Dissolved Salts Concentration in the Euphrates River upper reach, Iraq
...Show More Authors

       The Euphrates River Basin in Iraq suffers from climate changes represented by the scarcity of precipitation and the increase in temperatures, which is directly reflected in the discharge rates and the increase in total dissolved solids, and consequently, the increase in the dissolved loads in the river. Four measurement stations (Haditha, Ramadi, Fallujah, and Al-Hindiya) in the upper reach of the Euphrates River were investigated. Available data were analyzed from 1970 to 2020 related to precipitation (mm) and temperatures (°C). The results showed a clear decrease in precipitation rates over the years, while a clear increase in air temperature rates was observed. The discharge rates decreased temporally and spatially downs

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
Optical Properties of Manufactured Mirrors Using DC Plasma Magnetron Sputtering Technique
...Show More Authors

    This paper defines a method for sputtering high strength, extremely conductive silver mirrors on glass substrates at temperatures ranging from 20o to 22o C. The silver coated layer thicknesses in this work ranges from 7.5 to 16.1 nm using sputtering time from 10 to 30 min at power 25 W, 13.7 to 29.2 nm for time 10 to 30 min at 50 W, 15.7 to 26.4 nm for time 10 to 30 min at 75 W and 13.8 to 31.1 nm for time 10 to 30 min at 100 W. The optimum values of pressure and electrode gape for plasma sputtering system are 0.1 mbar and 5 cm respectively. The effect of DC sputtering power, sputtering duration or (sputtering time), and thickness on optical properties was investigated using an ultraviolet-visible spectrophot

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Effect of Fe2O3 Nanoparticles Dust on the D.C Plasma Characteristics with Mirror Magnetron
...Show More Authors

     In this paper, the effect of iron oxide nanoparticles dust (Fe2O3 NPs) on the parameters of DC electric discharge plasma under vacuum in argon gas was studied with the presence of a mirror magnetron behind the electrodes (cathode and anode) at constant pressure and with different amounts of Fe2O3 nanoparticles. Calculations presented a reduction of the plasma emission intensity with the NPs content. Both the plasma density (calculated by Stark's broadening method) and the mean electron temperature (calculated using Boltzmann's equation) decreased with increasing the Fe2O3 nanoparticles dust content, which indicates clearly the effect of dust density on restricting

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Effect of the Clenbuterol drug in some physiological parameters in male rabbits(Oryctolagus cuniculs)
...Show More Authors

This study was designed to investigate the effect of the Clenbuterol drug in some physiological parameters of Liver, Kidney function and lipidprofie concentration. Fourty adult male rabbits were used in this study. The animals were randomly divided into four groups,the first group was given distilled water (control) ,while the other third groups were given (2,4,6 µg/kg) of Clenbuterol drug for 30 days. Blood samples were collected after 14 and 30 days of the treatment for biochemical study. Drug caused non significant increase(P<0.05)in the AST and ALT enzymeactivity in second and third groups during treatment period ,while we note a significant increase(P<0.05) in both AST,ALT enzyme level in fourth group compared with control group , as

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
The effect of Tramadol on some blood and biochemical parameters of male rats (Rattus norvegicus)
...Show More Authors

The present study aimed to explain the dose-dependent possible deleterious effects of 30 day administration of Tramadol on some hematological and biochemical parameters of laboratory male rats (Rattus norvegicus), the study consisted of eighteen adult male rats randomly divided into three equal groups (each of six). Group 1 (control) were treated by intraperitoneal injection of normal saline solution (0.2 ml), group two (low dose) was treated by intraperitonealy (i.p) injection of Tramadol at a dose of 50 mg/kg/day, group three (high dose) was treated by intraperitonealy injection of Tramadol at a dose of 100 mg/kg/day for 30 days. At the end of experimental period, rats were sacrificed. Blood were collected by cardiac puncture to inv

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Journal Of Science
Effect of a Ketogenic Diet on Some Biochemical Parameters in Obese People
...Show More Authors

     This study examined the effects of a few biochemical variables on obese Iraqi males and females with a 30.5 body mass index (BMI) when they were fed a ketogenic diet. The present study demonstrates how an individual who follows a ketogenic diet has an increase in low-density lipoprotein (LDL-cholesterol). This research's objective was to assess the levels of some biochemical variables in obese people who were eating a ketogenic diet. Following 35 days on a ketogenic diet, the results show a significantly higher P ≤ 0.05 level of low-density lipoprotein (LDL) and total cholesterol (TC). Additionally, insulin, fasting blood sugar (FBS), cortisol, HOMA-IR, urea, BMI, and creatinine all show a considerable reduction, P ≤

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Effect of iodine doping on the characteristics of polythiophene thin films prepared by aerosol assisted plasma jet polymerization at atmospheric pressure
...Show More Authors

Iodine-doped polythiophene thin films are prepared by aerosol assisted plasma jet polymerization at atmospheric pressure and room temperature. The doping of iodine was carried out in situ by employing iodine crystals in thiophene monomer by weight mixing ratios of 1%, 3%, 5% and 7%. The chemical composition analyses of pure and iodine-doped and heat-treated polythiophene thin films are carried out by FTIR spectroscopy studies. The optical band gaps of the films are evaluated from absorption spectrum studies. Direct transition energy gaps are determined from Tauc plots. The structural changes of polythiophene upon doping and the reduction of optical band gap are explained on the basis of the results obtained from FTIR spectroscopy, UV–V

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
The Effect of Grain Size-Secondary Electron Emission on Grain Growth in Dusty Plasma
...Show More Authors

The calculation of the charge on an isolated dust grain immersed in plasma with different grain sizes is a challenging one, especially under moderately high plasma temperature when secondary electron emission significant. The discrete charging model is used to calculate the charges of dust grain in dusty plasma. In this model, we included the effect of grain size dependence on secondary electron emission. The results show that the secondary electron emission from the glass dust grains due to energetic electron (40eV) can lead to the small grain to be slightly more positive than the large grain. Under these conditions, the smaller and larger grains would be attracted rather than repelled, which possibly lead to enhanced coagulation rates.

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Double probe for measuring the plasma parameters
...Show More Authors

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing

... Show More
View Publication Preview PDF