In this work, a solid core photonic crystal fibre (SC-PCF) has been designed with endlessly single mode of which both centerd core and holes in the cladding are organized by circles. The designed SC-PCF has a single solid centerd core which is ringed by a six rings hexagonal cladding. The computation of SC-PCF is achieved by using the finite element method (FEM) with perfectly matched layer (PML) boundary condition. All the designed factors like dimensions and distance of both core and cladding areas have varied with an optimized structure. After ending the numerical calculation, the results shows that there are a link between the air hols in the cladding , and the different normalized air hole size.
Oral tablets containing solubilized drug in the presence of appropriate excipients may give us an immediate release of the drug. Phospholipid solid dispersion (PSD) is a branch of solid dispersion in which phospholipid acts as a hydrophilic polymer in the presence of a suitable adsorbent to enhance the solubility of poorly soluble drugs. The anti-hyperlipidemic drug Atorvastatin (ATR) is an example of such drug, as it belongs to the class II group according to the biopharmaceutical classification system (BCS) with low bioavailability due to its low solubility. Phosphatidylcholine in combination with magnesium aluminum silicate as an adsorbent in a ratio of ATR: PC: MAS 1:3:4 was used to prepare ATR PSD by the solvent evaporation method, the
... Show MoreAtorvastatin (ATR) is a poorly water-soluble anti-hyperlipidemic drug. The drug belongs to the class II group according to the biopharmaceutical classification system (BCS) with low bioavailability due to its low solubility. Solid dispersion is an effective technique for enhancing the solubility and dissolution of drugs. Phospholipid solid dispersion (PSD) using phosphatidylcholine (PC) as a carrier with or without adsorbent (magnesium aluminum silicate, silicon dioxide 15nm, silicon dioxide 30nm, calcium silicate) was used to prepare ATR PSD using different drug: PC: adsorbent ratios by solvent evaporation method. The resulted PSD was evaluated for its percentage yield, drug content, solubility, dissolution rate, Fourier transforma
... Show MoreIn this experimental and numerical analysis, three varieties of under-reamed piles comprising one bulb were used. The location of the bulb changes from pile to pile, as it is found at the bottom, center, and top of the pile, respectively.
This paper proposes a new structure for a Fractional Order Sliding Mode Controller (FOSMC) to control a Twin Rotor Aerodynamic System (TRAS). The new structure is composed by defining two 3-dimensional sliding mode surfaces for the TRAS model and introducing fractional order derivative integral in the state variables as well as in the control action. The parameters of the controller are determined so as to minimize the Integral of Time multiplied by Absolute Error (ITAE) performance index. Through comparison, this controller outperforms its integer counterpart in many specifications, such as reducing the delay time, rise time, percentage overshoot, settling time, time to reach the sliding surface, and amplitude of chattering in control inpu
... Show MoreThis research adopts the estimation of mass transfer coefficient in batch packed bed distillation column as function of physical properties, liquid to vapour molar rates ratio (L / V), relative volatility (α), ratio of vapour and liquid diffusivities (DV / DL), ratio of vapour and liquid densities (ρV / ρL), ratio of vapour and liquid viscosities (μV/ μL).
The experiments are done using binary systems, (Ethanol Water), (Methanol Water), (Methanol Ethanol), (Benzene Hexane), (Benzene Toluene). Statistical program (multiple regression analysis) is used for estimating the overall mass transfer coefficient of vapour and liquid phases (KOV and KOL) in a correlation which represented the data fairly well.
KOV = 3.3 * 10-10
... Show MoreBackground: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.
Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.
Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V. Ultrasound guided core needle biopsy was performed for each patient. Surgical pathol
... Show MoreAbstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability. Furthermore, the sensor is shif
... Show MoreThe aim of this research is to employ the roundhouse strategy to study its impact on the students achievement of the 10th grade in physics and their core thinking. After the application of the research experience and gaining data, which was processed statistically using the statistical packages program (SPSS). The results of the researcher revealed the superiority of the students of the experimental group who studied using the roundhouse strategy on the students of the control group who studied the usual method in the achievement test. As results showed that there were statistically significant differences between the average scores of the experimental group and the average scores of the control group students in the core thinking test and
... Show More