Preferred Language
Articles
/
jih-1866
Synthesis , Characterization and Study of Biological Activity of Some New Schiff Bases ,1,3-Oxazepine and Tetrazole Derived from 2,2 di thiophenyl Acetic Acid
...Show More Authors

         In this study  new  derivatives  of  Schiff bases 5-8 , 1,3- oxazepine  9-16 and tetrazoles 17-19 have  been synthesized from the new starting  material 1 which has  synthesized  the reaction of  one mole of dichloro acetic acid and two moles of  thiophenol , the esters  2-3 were synthesized from the reaction of  compound 1 with methanol or ethanol respectively  in the presence of  H2SO4  as  catalyst  then 2,2-dithiophenylaceto Hydrazide  4 were synthesized from the reaction of  2 or 3 with hydrazine hydrate  80 % , Schiff bases 5-8 were  synthesized from the reaction of  4 with appropriate aldehyde or ketone .Treatment  of  Schiff bases with maleic and phathalic  anhydride in dry benzene to give 1,3-oxazepen derivatives  9-16 and with sodium azide in tetrahydrofuran (THF) afforded  tetrazole derivatives 17-19. All these compounds have been characterized from their melting pointes, FTIR , 1HNMR and compounds 1,5 and 18 by mass spectrometry . Derivatives 6,7,11,16,17 and 18 were tested against inhibition of E.coli and. Staphylococcus- aureus and were all funds to be active. Scheme (1).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Aip Conf. Proc. 2450, 020031 (2022)
The study of the identification and association of adiponectin and Interleukin-6 and some variables. Biochemical parameters in the Iraqi cord blood of newborns
...Show More Authors

t. The current study was conducted on the umbilical cord blood of newborns in the Banks Hospital in Baghdad, Diyala, and Khalis in Diyala, where the study included 90 samples of blood, and samples were collected for the period from the 1st of October;2020 to The first of February;2021 AD, where the study included measuring levels of interleukin-6;Adiponectin,glucose and bilirubin in the blood, comparison study between the study variables with the child's weight (greater than 3 kg),(less or equal 3 kg),the mother's age (greater than 25 years, less or equal to 25 years),the sex of the child (male, female).The results of our study showed that there were no significant differences between the variables of the current study between the two sex

... Show More
Scopus Crossref
Publication Date
Sun Mar 30 2025
Journal Name
Studia Universitatis Babeș-bolyai Chemia
GREEN SPECTROPHOTOMETRIC METHOD FOR CONCURRENT ESTIMATION OF PIROXICAM AND MEFENAMIC ACID MIXTURE
...Show More Authors

The purpose of this work is to concurrently estimate the UVvisible spectra of binary combinations of piroxicam and mefenamic acid using the chemometric approach. To create the model, spectral data from 73 samples (with wavelengths between 200 and 400 nm) were employed. A two-layer artificial neural network model was created, with two neurons in the output layer and fourteen neurons in the hidden layer. The model was trained to simulate the concentrations and spectra of piroxicam and mefenamic acid. For piroxicam and mefenamic acid, respectively, the Levenberg-Marquardt algorithm with feed-forward back-propagation learning produced root mean square errors of prediction of 0.1679 μg/mL and 0.1154 μg/mL, with coefficients of determination of

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Paracetamol by Diazotization and Coupling Reaction with Anthranilic Acid
...Show More Authors

This paper concerned with development of a spectrophotometric method for the determination of paracetamol, based on the diazotisation and coupling reaction with anthranilic acid in basic medium, to form an intense yellow coloured, water-soluble and stable azo-dye which shows a maximum absorption at 421nm. Beer’s law is obeyed over the concentration range of 1.0-10 µg/ml; with molar absorptivity of 2.1772×104 L.mol -1.cm-1 and Sandell’s sensitivity index 6.9446 µg.cm-2. The method has been applied successfully for the determination of paracetamol in pharmaceutical formulation. 

View Publication Preview PDF
Publication Date
Tue Mar 20 1990
Journal Name
المجلة العراقية للعلوم
INACTIVATION OF GENTAMYCIN AND STREPTOMYCIN TOXICITY AGAINST E.COLI BY AMINO ACID SUPPLEMENTATION
...Show More Authors

Various nutritional solutions given to patients contain amino acids. Possible interference of this supplementation with selected aminoglycoside antiboiotics, namely gentamycin and streptomycin was evaluated in vitro. In minimal medium, E.coli was inhibited by gentamycin and by streptomycin. Circumvention of this inhibition was obtained with a mixture of 20 amino acids in the medium. Deletion of amino acids revealved that circumvention. specific amino acids were required for such Deletion of the aromatic amino acids or cysteine abolished the protection against gentamycin and streptomycin, while the deletion of the branched chain amino acids abolished the protection against streptomycin only. Thereonine, on the other hand, appears to be essen

... Show More
Publication Date
Sun Mar 30 2025
Journal Name
Studia Universitatis Babeș-bolyai Chemia
GREEN SPECTROPHOTOMETRIC METHOD FOR CONCURRENT ESTIMATION OF PIROXICAM AND MEFENAMIC ACID MIXTURE
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Agricultural And Statistical Sciences
Effect of foliar spraying with gibberellic and humic acid on wheat growth
...Show More Authors

Scopus (9)
Scopus
Publication Date
Mon Apr 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determinations of Sulfacetamide Following Simple Diazotization and Coupling with Chromotropic Acid
...Show More Authors

A simple, sensitive, accurate and economic spectrophotometric method has been developed for the determination of sulfacetamide (SFA) in pure form, synthetic sample and urine. The method is based on diazotization of primary amine group of sulfacetamide with sodium nitrite and hydrochloric acid followed by coupling with chromotropic acid in alkaline medium to obtain a stable orange colored chromogen which exhibit a maximum absorption (λmax) at   511.5 nm. Different variables affecting the completion of reaction have been carefully optimized following the classical univariate sequence and  modified simplex method (MSM). Under optimized conditions, Beer’s law obeyed in the concentration range of (0.5-  &nbs

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare

... Show More
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts.

Objectives:<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Working Memory Classification Enhancement of EEG Activity in Dementia: A Comparative Study
...Show More Authors

The purpose of the current investigation is to distinguish between working memory ( ) in five patients with vascular dementia ( ), fifteen post-stroke patients with mild cognitive impairment ( ), and fifteen healthy control individuals ( ) based on background electroencephalography (EEG) activity. The elimination of EEG artifacts using wavelet (WT) pre-processing denoising is demonstrated in this study. In the current study, spectral entropy ( ), permutation entropy ( ), and approximation entropy ( ) were all explored. To improve the  classification using the k-nearest neighbors ( NN) classifier scheme, a comparative study of using fuzzy neighbourhood preserving analysis with -decomposition ( ) as a dimensionality reduction technique an

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref