By using precipitation polymerization, liquid electrodes of polymers imprinted with Mebeverine hydrochloride and metronidazole benzoate were created whereas the imprinted polymer (MIP) and non imprinted (NIP) polymers were prepared by using Mebeverine hydrochloride and Metronidazole benzoate qua a template. In the polymerization process, 2-Acrylamido-2-methyl-1-propane Sulphonic acid (AMPS) or 1-Vinylimidazole (VIZ) was used qua monomer, pentaerythritol triacrylate (PETRA) or Divinylbanzene (DVB) was used qua a cross-linker while benzoyl peroxide (BPO) was used as an initiator. The MIP membranes and the membranes of NIP were created by using Dibutyl Sebacate (DBS) and Tris(2-ethylhexyl)phosphate(TEHP) qua plasticizers in PVC matrix. The response time of the liquid electrodes was 1min. whereas their slopes and detection limits reached to 19.62 – 57.36 mV per decade and 1.2 x 10-6 – 2.0 x 10-5 M, respectively. Filling with standard solution of drug (0.1M), the liquid electrodes response -with suitable No.( selectivity for numerous of species - was suitable No.( since pH reached to 1.5 – 12. The developed electrodes were successfully applied for the analyte determination in preparation pharmaceutical sample without any time consuming pretreatment steps.
A new, simple, accurate, fast and sensitive spectrophotometric method has been
developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure
commercial samples by continuous flow injection analysis. The method was based on
the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to
formed a brown colored species which determined using homemade Ayah 3SBGR x3-
3D solar cell flow injection microphotometer. Optimum conditions were obtained
using a high intensity green light emitted diode as an irradiation source
forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for
pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol,
In this study four cheese samples were randomly collected from local markets. These cheese samples were Ishaqi, Danone, Arab white cheese and Agricultural college cheese.
Results obtained revealed that all these cheese samples were contaminated by fungi in addition to the presence of same heavy metals under study which were Fe, Pb, Ni and Cr. All fungal contaminat were identified which were contaminated them in winter (January). However, fungal pollution in summer was 100% while in winter was 50% Aspergillus niger was polluted chees samples100% in summer while it was 75% in winter. Aspergillus fumigatus was polled cheese samples under study 50% in summer and 0% in winter .Results for heavy metals determination revealed that Fe was con
The kinetic of atropine pertraction from seeds of Datura Metel Linn plant was studied. Diisopropyl ether, n-hexane and n-heptane were used as membranes for atropine recovery. The effect of speed of agitation and time in the range of 200-300 rpm and 0-3.5h, respectively were studied using the proposed membranes. The pertraction experiments were carried outs in a batch laboratory unit. The liquid-liquid pertraction was found to be very suitable for atropine recovery from its liquid extracts of Datura Metel seeds. A high purity (94-96%) can be obtained in the receiver phase. The pertraction process was found to be very selective for atropine recovery with diisopropyl ether membrane. As the speed of agitation increases the efficiency of pertrac
... Show MoreThe ion-pair formation method has been applied for the spectrophotometric determination of Cimetidine and Erythromycin ethylsuccinate, in bulk samples and in dosage form. The methods are accurate, simple, rapid, inexpensive and sensitive depending on the extraction of the formed ion-pair with brompthymol blue (BTB) as a chromogenic reagent in chloroform, use phthalate buffer of pH 5.5 and 4.0 for Cimetidine and Erythromycin ethylsuccinate respectively. The formed complexes show absorbance maxima at 427.5 nm and 414.5 nm for Cimetidine and Erythromycin ethylsuccinate respectively against reagent blank. The calibration graphs are linear in the ranges of 0.5-15 µg.mL-1 with detection limit of 0.222 µg.mL-1 for
... Show MoreThe present study was conducted to investigate the resistance of fluoroquinolones (FQs) and the effects of mutations in the resistance gene in clinical isolates of P. aeruginosa isolated from different sources in Al-Hussein Hospital, Al-Samawah city, Iraq. The basic mechanism of the resistant of fluoroquinolones in P. aeruginosa is via mutations occurring in the basic bacterial gyrA gene encoding-subunit A of DNA gyrase . Forty clinical isolates from various sourced (burn 7 (17.5 %), wound 7 (17.5 %), ear 2 (5 %), operation room 12 (30 %), urine 3 (7.5 %), and industrial dialysis center 9 (22.5 %)) were isolated based on bacteriological methods confirmed by 16s rRNA gene using PCR technique. A se
... Show MoreThe present study was performed to detect the molecular and the phylogenetic identification of species that belonging to the genus of Moniezia Blanchard, 1891 which affected intestines of sheep in Al-Diwaniyah city, Iraq; fifty intestine samples were sought for the infestation of Moniezia spp. from the city slaughterhouse from 1 October to 30 November 2017, this tapeworm was found to infest the intestines of 13 sheep.
For morphological identify the genus of this tapeworm, eggs from one gravid proglottid of the thirteen worms were examined, polymerase chain reaction (PCR) and the PCR-product-based sequencing were applied on 4 Moniezia tapeworms targeti
... Show MoreA simple ,accurate and sensitive spectrophotometric method has been developed the determination of Cobalt(II) and Cupper (II) .The method is based on the chelation of Co(II) and Cu(II) ions with 4-(4´-pyrazolon azo) -2-Naphthol(APAN) in aqueous medium . The complexes have a maximum absorption at (513) and (506) nm and ? max 0.531×10 4 and 0.12×10 5 L.mol -1.cm -1 for Co(II) and Cu(II) respectively .The reagent and two complexes have been prepared in ethanolic solution.The stoichiometry of both complexes were found to be 1:2 (metal :legend) .The effects of various cations and anions on Co(II) and Cu(II) determination have been investigated .The stability constants and standard deviations for Co(II) and Cu(II) 0.291 x107 ,0.909X108 L.mol
... Show More