Preferred Language
Articles
/
jih-1847
Detection and Detoxification of Aflatoxin B1 from Fish Feedstuff Using Microwave and Ozone Gas
...Show More Authors

    The current study was designed to investigate the occurrence of aflatoxin B1 in thirty two samples of fish feedstuff were collected randomly from some Iraqi local markets using ELISA technique. Aflatoxin B1 was detected in thirty samples and the concentration of toxin ranged from 50 ppb to 1000 ppb.  

   Microwave and ozone were used for detoxification of aflatoxin B1 from sample with highest concentration (1000 ppb), two degree of temperature and two times (50°C and 100°C for 5 minute and 10 minute to each degree) of microwave, also two doses and two times (2 g and 4 g for 5 minute and 10 minute to each dose) of ozone gas were used.

   Degradation of aflatoxin B1 by microwave has been found to cause a significant (P ≤ 0.05) decrease of aflatoxin B1, Moreover, the concentration of aflatoxin B1 was dependent on temperature degrees and exposure time, also sample subjected to ozone gas caused a significant (P ≤ 0.05) decrease in aflatoxin B1 contents and the concentration of aflatoxin B1 was dependent on doses and times of exposure. Results showed that ozone gas was more effective in aflatoxin B1 reduction when compared with microwave.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Aip Conference Proceedings
CT scan and deep learning for COVID-19 detection
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Feb 27 2021
Journal Name
Iraqi Journal Of Science
Automatic Pectoral Muscles Detection and Removal in Mammogram Images
...Show More Authors
The main aim of the Computer-Aided Detection/Diagnosis system is to assist the radiologists in examining the digital mammograms. Digital mammogram is the most popular screening technique for early detection of breast cancer. One of the problems in breast mammogram analysis is the presence of pectoral muscles region with high intensity in the upper right or left side of most Media-Lateral Oblique views of mammogram images. Therefore, it is important to remove this pectoral muscle from the image for
... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Vanadium and Nickel Ions from Iraqi Atmospheric Residue by Using Solvent Extraction Method
...Show More Authors

Iraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal percent we

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Adsorption of Chromium (Vi) from Aqueous Solutions using Low Cost Adsorbent: Equilibrium and Regeneration Studies
...Show More Authors

The adsorption of Cr (VI) from aqueous solution by spent tea leaves (STL) was studied at different initial Cr (VI) concentrations, adsorbent dose, pH and contact time under batch isotherm experiments The adsorption experiments were carried out at 30°C and the effects of the four parameters on chromium uptake to establish a mathematical model description percentage removal of Cr (VI). The
analysis results showed that the experimental data were adequately fitted to second order polynomial model with correlation coefficients for this model was (R2 = 0.9891). The optimum operating parameters of initial Cr (VI) concentrations, adsorbent dose, pH and contact time were 50 mg/l, 0.7625 g, 3 and 100 min, respectively. At these conditions, th

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Increasing of Naphthenes Content in Naphtha by Using Y and  Zeolite Prepared from Iraqi Kaolin
...Show More Authors

This work dealt with separation of naphthenic hydrocarbons from non-naphthenic hydrocarbons and in particular concerns an improved process for increasing the naphthenes concentration in naphtha, The separation was examined using adsorption by Y and  B zeolite in a fixed bed process. The concentration of naphthenes in the influent and effluent streams was determined using PONA classification. The effect of different operating variables such as feed flow rate (2- 4 L/hr); bed length (50 - 80 cm) on the adsorption capacity of Y and  zeolite was studied. Increasing the bed length lead to increase the naphthenes concentration, and increasing the flow rate lead to decrease in the concentration of naphthenes, It was found that the decrease

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Vanadium and Nickel Ions from Iraqi Atmospheric Residue by Using Solvent Extraction Method
...Show More Authors

Iraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal perce

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Proceedings Of The 5th International Conference On Information Systems Security And Privacy
Identification and Extraction of Digital Forensic Evidence from Multimedia Data Sources using Multi-algorithmic Fusion
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Dec 23 2021
Journal Name
Iraqi Journal Of Science
Spatial Analysis of the CO Emission from Nineveh Governorate Using Remote Sensing Techniques and GIS
...Show More Authors

     Carbon Monoxide (CO) has a significant indirect effect on greenhouse gasses due to its ozone and carbon dioxide precursor, and its mechanism of degradation involving the hydroxyl radical (OH) which control the oxidizing ability of the tropospheric. To understand the effect of human activities on atmospheric composition, accurate estimates of the sources of atmospheric carbon monoxide (CO) are necessary. MOPITT (Measurements of Pollution in the Troposphere) is a NASA Terra satellite instrument designed to allow both Thermal-Infra-Red (TIR) and Near-Infra-Red (NIR) observations to be used to collect vertical CO profiles in the Troposphere via the concept of correlation spectroscopy. The objective of the current stu

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Aug 28 2020
Journal Name
Iraqi Journal Of Science
Biosorption of Lead and Chromium Ions by Using Penicillium digitatum (Pers.) Sacc. from Industrial Water
...Show More Authors

Some microorganisms, including fungi, are characterized by their removal efficiency and reducing the concentrations of heavy metals such as Pb and Cr from industrial water. The present study aims to estimate the efficiency of Penicillium digitatum (Pers.) Sacc. as a low-cost biosorbent in reducing Pb and Cr from industrial water with optimum biosorption conditions (acidity of 1.5 , 4, and 5; temperature of 30 °C). The Fourier transform infrared spectroscopy (FTIR) analysis was also used for determining the roles of the functional groups in this biosorbent. The results indicated that the highest P. digitatum efficiency values for reducing the levels of Pb and Cr were 84% and 70% , respectively, at pH of 5 after 24 h.

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Study the effect of fish in alternating electrical properties of copper oxide membranes CuO
...Show More Authors

In this research study the effect of fish in alternating electrical properties at room temperature copper oxide membranes and fish prepared in a manner different thermal spraying chemical on a thin glass bases and heated

View Publication Preview PDF