Preferred Language
Articles
/
jih-1613
Glutamic Acid as Corrosion Inhibitor for Aluminium in Acidic Medium
...Show More Authors

 Corrosion behavior of aluminium in 0.6 mol. dm-3 NaCL solution in acidic medium (      ) was investigated in the absence and presence of different concentrations of amino acid, glutamic acid, as environmentally – friendly corrosion inhibitor over temperature range (293-308)K. The investigation involved electrochemical polarization method using potentiostatic technique and optical microscopy, the inhibition efficiency increased with an increase in inhibitor concentration but decreased with increase in temperature. Results showed that the inhibition occurs through adsorption of the inhibitor molecules on the metal surface and it was found to obey Langmuir adsorption isotherm. Some thermodynamic parameters (      ) and activation energy (  )were calculated to elaborate the mechanism of corrosion inhibition. The polarization measurements indicated that glutamic acid is of mixed type. The surface characteristic of the inhibited and uninhibited metal samples were investigated by optical microscopy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Surfaces And Interfaces
Corrosion performance of electrospinning nanofiber ZnO-NiO-CuO/polycaprolactone coated on mild steel in acid solution
...Show More Authors

View Publication
Scopus (35)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2017
Journal Name
Journal Of Engineering
Aluminium Matrix Composites Fabricated by Friction Stir Processing A Review
...Show More Authors

      Aluminum alloys widely use in production of the automobile and the aerospace because
they have low density, attractive mechanical properties with respect to their weight, better
corrosion and wear resistance, low thermal coefficient of expansion comparison with traditional
metals and alloys. Recently, researchers have shifted from single material to composite materials
to reduce weight and cost, improve quality, and high performance in structural materials.
Friction stir processing (FSP) has been successfully researched for manufacturing of metal
matrix composites (MMCs) and functional graded materials (FGMs), find out new possibilities
to chemically change the surfaces. It is shown th

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
The International Journal Of Biotechnology,
LACTIC ACID AS SPACER BETWEEN POLY ACRYLIC ACID AND 4- AMINOANTIPYRINE
...Show More Authors

Preview PDF
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Study of Serum GOT(Glutamic Oxalacetic Transaminase) Activity and Some kinetic Parameters in Patient with Pulmonary Tuberculosis
...Show More Authors

   In the present study, serum GOT(Glutamic Oxalacetic Transaminase) was purified, the purified enzyme showed the maximum activity at 37ºC and pH 7.5. During purification of serum GOT ion exchange chromatography lead to four separate forms (termed I, II, III and IV). GOT II with  the highest specific activity was pure after chromatography on Sephacryl S300. . S.GOT levels were investigated in serum samples from patient with pulmonary tuberculosis .The S.GOT levels were determined at and 37ć .The study revealed that the serum GOT activity was higher in patient of tuberculous pulmonary than in control subjects.The mean serum GOT activity in the patients group was(90±8 IU/L) as compared to control group (27±0.65I

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 22 2021
Journal Name
International Journal Of Corrosion And Scale Inhibition
Synthesis of a CoO–ZnO nanocomposite and its study as a corrosion protection coating for stainless steel in saline solution
...Show More Authors

Reaxys Chemistry database information SciVal Topics Metrics Abstract A novel CoO–ZnO nanocomposite was synthesized by the photo irradiation method using a solution of cobalt and zinc complexes and used as a coating applied by electrophoretic deposition (EPD) for corrosion protection of stainless steel (SS) in saline solution. The samples were characterized using powder XRD, scanning electron microscopy (SEM) and electrochemical polarization. It was also found that the coating was still stable after conducting the corrosion test: it contained no cracks and CoO–ZnO nanocomposites clearly appeared on the surface. SEM showed that the significant surface cracking disappeared. XRD confirmed that CoO–ZnO nanocomposites comprised CoO and Zn

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Performance Evaluation for Higher and Medium Leadership in Institutional Work Quality.
...Show More Authors

Abstract:

This Research aims to define role of the system of evaluating the performance for higher leadership in determining the level of institutional work quality in the Ministry of Agriculture, by measuring system efficiency of evaluating the performance for higher leadership and its effect in institutional work quality, the searcher reached through the theoretical framing and involved studies to build default plan define the relation between Research variables formed from system of evaluating leadership performance as independent variable contains six subsidiary dimensions: (Polarization, evaluating the performance of personnel, training, motivation, se

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 20 2018
Journal Name
Al-academy
Directed by Treatment for single-place events in the cinematographic medium
...Show More Authors

The cinematographer mediates through the means of cinema and television a set of elements complementing each other in the light of developments in various sciences, culture and arts for the purpose of conveying the meaning to the recipient and achieve aesthetic taste. Despite the diversity of cinematographic media with its multiple forms, The researcher started from the principle of definition and knowledge of a technical phenomenon that emerged in the cinematographic medium through the treatment of dramatic events through the solutions of the exit line depends on the narrative of events in one place contributes to attract Mam spectator since this interesting phenomenon in the mediator, there .van question arises the adoption of that vis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 17 2021
Journal Name
Materials
Recycled Concrete Aggregate for Medium-Quality Structural Concrete
...Show More Authors

This paper reports an evaluation of the properties of medium-quality concrete incorporating recycled coarse aggregate (RCA). Concrete specimens were prepared with various percentages of the RCA (25%, 50%, 75%, and 100%). The workability, mechanical properties, and durability in terms of abrasion of cured concrete were examined at different ages. The results reveal insignificant differences between the recycled concrete (RC) and reference concrete in terms of the mechanical and durability-related measurements. Meanwhile, the workability of the RC reduced vastly since the replacement of the RCA reached 75% and 100%. The ultrasound pulse velocity (UPV) results greatly depend on the porosity of concrete and the RC exhibited higher poros

... Show More
View Publication
Scopus (24)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Thu Sep 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Control of Calcium Scale and Corrosion of Medical City Cooling Water System using Sulfuric Acid
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Inhibition Of Low Carbon Steel In Washing Water Of Crude Oil Solution In The Presence Of Folic Acid
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range (30–70)°C .The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature. Folic acid had on inhibiting effect on the corrosion of low carbon steel in washing water at a concentration (5× 10-4-- 5× 10-3 ) mol/dm3 over the temperature range (30–70)°C. Values of the protection efficiency were calculated from the corrosion current density .From the general results for this study, it can be seen that thermodynamic and kinetic function were also calculated (?G, ?S, ?H and Ea )

... Show More
View Publication Preview PDF
Crossref (3)
Crossref