Comparison of Serum Iron and Total Iron Binding Capacity Between Hemo and Peritoneal Dialysis Patients
...Show More Authors

In  this  study,  20  patients  were  selected    having  renal  failure  .10 patients  were  hemo&  10  peritoneal  dialysis  procedure. Patients  had been  given  r HuEPO    subcutaneous with supplement of Iron  dextran after  di alysis  . Hemoglobin  Hb  concentration Hematocrit(Hct),serum I ron ,total  Iron  binding  capacity,     transferrin  saturation percent  Ts%

&    Serum    ferritin    were   measured.    Non    significant    changes    in hemoglobin, hematocrit,                                 serum  Iron ,totallron binding  capacity

,transferrin saturation but a significant  difference  in serum ferritin  was found ,this was a cribed to :

1-  The blood lost i n the peritoneal  or hemodialysis for access .

2-   Some  patients  had  been  given  blood  to treat  anemia  or given

Iron supplements which  leads to Iron overload.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 21 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Correlation between crevicular C-reactive protein level with its serum level in chronic periodontitis patients
...Show More Authors

Background: The main purpose of this study is to find if there is any correlation between the level of C-reactive protein (CRP) in gingival crevicular fluid with its serum level in chronic periodontitis patients and to explore the differences between them according to the probing depth. Materials and methods: Forty seven male subjects enrolled in this study. Thirty males with chronic periodontitis considered as study group whom further subdivided according to probing depth into subgroup 1 with pocket depth ≤6mm, subgroup 2 with pocket depth >6mm. The other 17 subjects considered as controls. For all subjects, clinical examination where done for periodontal parameters plaque index (PLI), gingival index (GI), bleeding on probing (BOP),

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal Of Dissolved Cadmium Ions from Contaminated Wastewater using Raw Scrap Zero-Valent Iron And Zero Valent Aluminum as Locally Available and Inexpensive Sorbent Wastes
...Show More Authors

The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed wer

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Study the Effect of Peganum Harmala Seeds Extracts to Protect Iron Alloy from Corrosion in Salt Media
...Show More Authors

This work describes the inhibition effect of different concentration of an aqueous extract of Peganum harmala seed on the corrosion of carbon steel in 3.5 % sodium chloride solution using potentiostatic polarization techniques at the temperature range of 25°C to 55°C. The result show that inhibition efficiency increased with increasing concentration of the inhibitor extracts and temperature. The adsorption of inhibitor on carbon steel surface was fit into Langmuir adsorption isotherm. Kinetic and thermodynamic parameters governing the corrosion and adsorption process were calculated and discussed.

View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Removal of Dissolved Trivalent Chromium Ions from Contaminated Wastewater using Locally Available Raw Scrap Iron-Aluminum Waste
...Show More Authors

The present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.

The best isotherm model for the batch single Cr(III) uptake by ZVI

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Sun Oct 02 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparative study between Harmonic FOCUSTM to clamp and tie technique for total thyroidectomy
...Show More Authors

Background: Thyroid surgery has undergone many changes during the past 2 decades, including the introduction of new surgical techniques such as endoscopic or video-assisted approaches, anesthesia care, intraoperative nerve monitoring and new hemostatic tools
Objectives: to assess the efficacy and safety of Harmonic Focus shears in total thyroidectomy compared with conventional surgical technique.
Patients and methods: prospective study conducted from October 2011 till January 2016, two handers and nine patients with benign and malignant thyroid diseases, scheduled for total thyroidectomy in a governor and private hospitals were enrolled randomly into 2 groups, group A consists of 105 patient who undergone a total thyroidectomy usin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Al-kindy College Medical Journal
The impact of advancing age on total serum IgE in asthmatic patient
...Show More Authors
 

Abstract

The current study was conducted to assess the effect of advancing age on total serum IgE level in asthmatic patients. To this purpose, 90 asthmatic patients and 30 healthy individuals ( control group ) were enrolled. Asthmatic patients were categorized into four groups. Group A consisted of asthmatic patients (9) whose age was more than 20 and up to 30 y. Group B contained asthmatics (13) of age more than 30 and up to 40 y. Group C comprised those (23) of more than 40 and up to 50 y. Group D consisted asthmatic patients (45) of age more than 50 y. Total serum IgE level significantly changed in group D patients when compared with those of

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparison between HSV-1 Ag detection techniques by ELISA and real-time PCR in breast cancer patients suffering from periodontitis
...Show More Authors

Background: Periodontitis is a long-standing infection that destroys the gums, periodontal ligaments, and the alveolar bone that supports the teeth. Inflammation of the gums and chronic periodontitis are both caused by the bacteria in the dental plaque and the herpes viruses, especially types 1 and 2 of the herpes simplex virus.

Objectives: To compare the ELISA and real-time PCR as ways to detect the herpes simplex virus in breast cancer pat

J Fac Med Baghdad

2023; Vol.65, No. 3

Received:March., 2023

Accepted: June. 2023

Published: Oct. 2023

 

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Engineering
Comparison of Groundwater Quality and Quantity between Al-Rahbah and Al-Haydariyah Regions
...Show More Authors

This study focused on two areas in AL-Najaf city, AL-Ruhbah and Al-Haydariyah regions because of the importance and widespread use of groundwater in these areas. The two areas were compared quantitatively and qualitatively. For the quantitative approach, the GMS software was used in conjunction with the GIS software to simulate the groundwater flow behavior. The solid model for both areas was created, the geological formation was determined, and the hydraulic properties were identified using GMS software. To test the quantity of groundwater in both areas, the wells have been redistributed to a distance of 2000 m between them, and a period of 1000 days was chosen. When a discharge of 10 l/s and operation times of 4, 8, an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2005
Journal Name
Iraqi Journal Of Science
Comparison between Zernike moment and central moments for matching problem
...Show More Authors

Moment invariants have wide applications in image recognition since they were proposed.

Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Comparison between Recycled Single Stage and Double Stage Hydrocyclones
...Show More Authors

   This research presents a comparison of performance between recycled single stage and double stage hydrocyclones in separating water from water/kerosene emulsion. The comparison included several factors such as: inlet flow rate (3,5,7,9, and 11 L/min), water feed concentration (5% and 15% by volume), and split ratio (0.1 and 0.9). The comparison extended to include the recycle operation; once and twice recycles. The results showed that increasing flow rate as well as the split ratio enhancing the separation efficiency for the two modes of operation. On the contrary, reducing the feed concentration gave high efficiencies for the modes. The operation with two cycles was more efficient than one cycle. The maximum obtained effici

... Show More
View Publication Preview PDF
Crossref (1)
Crossref