Preferred Language
Articles
/
jih-148
Spectrophotometric Determination of Diclofenac sodium Using 2,4-dinitrophenylhydrazine in Pure Form and Pharmaceutical Preparations
...Show More Authors

A simple and sensitive spectrophotometric method is described for the determination of diclofenac sodium (DCL), in pure form and pharmaceutical formulations. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPH) and coupling of the oxidized product with DCL in alkaline medium to give intensively colored chromogen which exhibits maximum absorption (λmax) at 600 nm, and the concentration of DCL was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, modified simplex method (MSM) has been applied in optimization of the variables affecting the color producing reaction. Beer’s law is obeyed in the concentration range of 0.5-40 µg.mL-1 with molar absorptivity of 2.0994×104 L.mol-1.cm-1. The limit of detection was found to be 0.020 µg.mL-1 and the Sandellʼs sensitivity value was 0.0152 µg.cm-2. The proposed method was successfully applied to the determination of DCL in pharmaceutical preparations. 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Analytical Potentiality of Computer - Controlled Background Correction with Electrothermal Atomic Emission Spectrometry : Determination of Copper in Milk Powder
...Show More Authors

A fully automatic electrothermal atomic emission spectrometry (ETA-AES) is described. This system is based on an echelle monochromator modified for wave¬length modulation which is completely controlled by microcomputer . The advantages of the system in atomic spectrometry have been discussed . Aspects of the analytical performances such as calibration ? dection limit, precision , and recovery for copper are considered . This system is applied for routine determination of copper in commercial powdered mill? by slurr>' atomization versus aqueous atomization techniques.

View Publication Preview PDF
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Role of Cone Beam Computed Tomography in Determination of the Greater Palatine Foramen Position Among Iraqi Population
...Show More Authors

Background: The use of the cone beam computed tomography for analysing the position of the greater palatine foramen in relation to various anatomical landmarks is crucial in dentistry. The aims of the current study, firstly is to determine the greater palatine foramen position in relation to various anatomical landmarks by using cone beam computed tomography and secondly is to make a comparison of the measurements according to side, gender, and age. Materials and methods: This prospective study included 60 Iraqi patients (28males and 32 females) who selected according to availability of Inclusion criteria, which include age range (21 - 60 years), with no dentofacial deformities or pathological lesion at the maxilla. All patients had inform

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Innovation, Creativity And Change (ijicc)
The relationship between conceptual knowledge and procedural knowledge among students of the mathematics department at the faculty of education for pure sciences/IBn Al-Haitham, university of Baghdad
...Show More Authors

Scopus (25)
Scopus
Publication Date
Mon Sep 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Thermogravimetric Method for Accurate Determination of Thermodynamic Quantities at High Temperatures
...Show More Authors

This researd exhibit's a method to  determine the change in Gibbs function,(enthai py,entropy.     and     specific     heat     capacity)      tor monovariant   heterogeneous   equilibria   .The  thermodynamical quan.tities were obtained jndirectly with m the measurment  of temperature dependent on eql,lilibrium system.

View Publication Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Steganography in Audio Using Wavelet and DES
...Show More Authors

In this paper, method of steganography in Audio is introduced for hiding secret data in audio media file (WAV). Hiding in audio becomes a challenging discipline, since the Human Auditory System is extremely sensitive. The proposed method is to embed the secret text message in frequency domain of audio file. The proposed method contained two stages: the first embedding phase and the second extraction phase. In embedding phase the audio file transformed from time domain to frequency domain using 1-level linear wavelet decomposition technique and only high frequency is used for hiding secreted message. The text message encrypted using Data Encryption Standard (DES) algorithm. Finally; the Least Significant bit (LSB) algorithm used to hide secr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 06 2020
Journal Name
Plant Archives
ROLE OF ANALYTICAL CHEMISTRY FOR THE DETERMINATION OF ASCORBIC ACID: A REVIEW
...Show More Authors

Vitamins play an important role in the human health, and thus they are the kind of major nutrients in the body. Chemical products perform numerous physiological functions and can jeopardize health jointly in their absence and surplus. Therefore, it is necessary to establish methods for observation vitamin levels in various molds. In this review paper, the most methods of determination used are high performance liquid chromatography (HPLC), spectrophotometric and potentiometric techniques by listed the value of : slope, linear range, correlation coefficient, detection limit, the max of wavelength and PH and compared with these methods.

Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Determination of the neutron refleetion coefficient as a function of reflector material
...Show More Authors

This work presents a simple method for determination of the neutron reflection coefficient (n) as a function of different neutron reflector materials.A laboratory neutron source (Am-Be) with activity of 16 ci is employed with a (BF3) neutron detector. Am-BeThree types of reflector materials are used as samples, the thickness of each sample is (5cm).It is found that( ?7) is: -For polyethlyene = 0.818

View Publication Preview PDF
Publication Date
Sun Dec 01 2024
Journal Name
Materials Letters
Determination of third order susceptibility of carbon quantum dots at different concentrations
...Show More Authors

The nonlinear refractive (NLR) index and third order susceptibility (X3) of carbon quantum dots (CQDs) have been studied using two laser wavelengths (473 and 532 nm). The z-scan technique was used to examine the nonlinearity. Results showed that all concentrations have negative NLR indices in the order of 10−10 cm2/W at two laser wavelengths. Moreover, the nonlinearity of CQDs was improved by increasing the concentration of CQDs. The highest value of third order susceptibility was found to be 3.32*10−8 (esu) for CQDs with a concentration of 70 mA at 473 nm wavelength.

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Oct 04 2004
Journal Name
International Conference On Geotechnical Engineering
The Equivalent Grain Diameter for Soil Specific Surface Determination
...Show More Authors

Publication Date
Fri May 10 2019
Journal Name
Research Journal Of Chemistry And Environment
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-

... Show More
View Publication