Preferred Language
Articles
/
jih-1470
Potentiometric Determination of Iodide in Magnesium Fluoride by Iodide Electrode
...Show More Authors

Iodide Ø¢ in samples Ø¢ containing Ø¢ magnesium Ø¢ fluoride Ø¢ was Ø¢ determinedØ¢  Ø¢ by using iodide selective Ø¢ electrode. Ø¢ Detecting Ø¢ the limit for iodide determination

was around Ø¢ 5x1 oآ·5Ø¢ Ø¢ M with a standard Ø¢ deviation Ø¢ ranged Ø¢ from Ø¢ Ø¢Â± 0.3 to آ± 0.6.

QuantitativeØ¢  Ø¢ methodsØ¢  Ø¢ including; standard Ø¢ additionØ¢  Ø¢ method, Ø¢ Potentiometric

titration Ø¢ by using a Gran plot paper for an equivalent Ø¢ point determination and a Ø¢ directØ¢  Ø¢ methodØ¢  Ø¢ wereØ¢  Ø¢ used Ø¢ for Ø¢ the Ø¢ analysis.Ø¢  Ø¢ DissolutionØ¢  Ø¢ of Ø¢ magnesium fluoride samples Ø¢ was investigated Ø¢ in various acids (HCI, HN03, HCI04, and H3P04). Good Ø¢ recovery Ø¢ of Ø¢ iodide Ø¢ was obtained Ø¢ by using Ø¢ hydrochloric and phosphoric Ø¢ acids Ø¢ for dissolution. Interference Ø¢ of Ø¢ uranyl Ø¢ ion and Ø¢ halide Ø¢ ions,

pآ·, cr,Ø¢ and Br- on iodide response was also studied. This method can be used

for the determination of iodide in magnesium Ø¢ fluoride obtained Ø¢ from uranium

metal production.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 06 2019
Journal Name
Journal Of The College Of Education For Women
Analysis of Errors in Paragraph Writing in English by Second Year Geography & History Students at University of Baghdad
...Show More Authors

This study focuses on the writing skill which is a social act .Students need to express
themselves in writing, but students of History and Geography departments are poor in
writing. This study aims at identifying and classifying the errors committed by the
students, and then giving remedies.
Writing can be considered as a channel or as a goal of language learning.
Students learn to write in a foreign language. Writing as a goal basically focuses on
the development of writing skills to fulfill such purposes as note-taking, summarizing,
narrating, reporting and replying required for various real-life situation
(Mechalakelli,2007)
Students at Departments of Geography and History study English as a part of
their

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Porous silicon prepared by photo electrochemical etching assisted by laser
...Show More Authors

Porous silicon (PS) layers are prepared by anodization for
different etching current densities. The samples are then
characterized the nanocrystalline porous silicon layer by X-Ray
Diffraction (XRD), Atomic Force Microscopy (AFM), Fourier
Transform Infrared (FTIR). PS layers were formed on n-type Si
wafer. Anodized electrically with a 20, 30, 40, 50 and 60 mA/cm2
current density for fixed 10 min etching times. XRD confirms the
formation of porous silicon, the crystal size is reduced toward
nanometric scale of the face centered cubic structure, and peak
becomes a broader with increasing the current density. The AFM
investigation shows the sponge like structure of PS at the lower
current density porous begi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
A new mode for an on-line determination of Pyrocatechol, Resorcinol, and Pyrogallol in pure commercial samples using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer.
...Show More Authors

A new, simple, accurate, fast and sensitive spectrophotometric method has been
developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure
commercial samples by continuous flow injection analysis. The method was based on
the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to
formed a brown colored species which determined using homemade Ayah 3SBGR x3-
3D solar cell flow injection microphotometer. Optimum conditions were obtained
using a high intensity green light emitted diode as an irradiation source
forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for
pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol,

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 05 2019
Journal Name
Journal Of The College Of Education For Women
Study of Nutritional Adequacy Provided by some Imported Infant Milk Formula Available in the Local Market: Study of Nutritional Adequacy Provided by some Imported Infant Milk Formula Available in the Local Market
...Show More Authors

Abstract:
This investigation was carried out to study the nutritional adequacy for
infant milk formula, which imported by Iraqi Ministry of Trade, and are
available in local markets .Most of these formulas contained nearly the same
composition of nutrients which are ,Matines ,Sunny Boy , Salsabeel AL- Badie
,Moroug, ,Charton ,Materna Lery Celia ,Lacstar Lailac,Nactalia. yet they are
unbalanced for providing the daily nutritional requirements for infants whom
depend on bottle feeding for six times daily in their first six month of age. As
there were an increase in daily intake for protein content and most vitamins
that included D, E, C, B1, B2, Niacin, B6, B12, and Biotin as well as most
minerals namely Calci

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Anti-tumor Activity of Plantago lanceolata Aqueous Extract In Vitro and Genotoxicity by Micronucleus Assay In Vivo
...Show More Authors

The study is designed to evaluate the effect of the aqueous extract of the P. lanceolata plant, as well as to know the effect of the drug CCl4 on the formation of micronucleus in vivo 48 female albino mice. In the study mice were separated into eight groups treated intraperitoneally for seven day first group Negative control, second positive control( CCl4 0.02%), third group aqueous extract (250 mg/kg), fourth group  aqueous extract (500 mg/kg), fifth group (CCl4 0.02%) plus aqueous extract (250 mg/kg), sixth group (CCl4 0.02%) plus aqueous extract (500 mg/kg), seventh group aqueous extract (250 mg/kg) plus (CCl4 0.02%), and eighth group aqueous extract (500 mg/kg) plus (CCl4 0.02%). The genetic-cellular asp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Genetic diversity of Capsicum annuum L. in local and imported samples in Iraq by using RAPD-PCR
...Show More Authors

Genetic variation was studied in 22 local and imported samples collected from local Iraqi market by using random amplified polymorphic DNA (RAPD-PCR). Five randomly primers set were used in this study. These primers produced 292 bands. Molecular weights of these bands ranged between 1.8 Kb (1800 bp) to 150 bp. The percentage of polymorphic bands is 100%, with one distinguished band which is produced by using C52 primer. The other primers did not produce any distinguished band. The results of Dendrogram of the studied samples depended on RAPD-PCR results by using Jaccard coefficient for genetic similarity was distributed the samples into 8 groups. This Dendrogram revealed a higher similarity between Iraqi/Yousifia green bell pepper and Jo

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Vanadium (V) In Different River Water via the Use of a Homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
...Show More Authors

A new simple sensitive and selective spectrophotometric method has been developed for the analysis of vanadium(V) in three randomly chosen samples from river water at different locations by continuous flow injection analysis. The method based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color species and the same species was determined using homemade Ayah 6SX1-T-2D solar cell analyser . Chemical and physical parameters were investigated using the high intensity of snow white light emitted diode as a source. The linear dynamic range for the instrument response versus vanadium(V) concentration was 1-200 mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70 ng/ sample from the step

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 03 2023
Journal Name
Iraqi Journal Of Science
New mode for the on-line determination of oxonium ion in different strong acids using CFIA via the use of homemade linear array Ayah 5Sx4-ST- 5D solar CFI analyser
...Show More Authors

New mode for the on-line determination of oxonium ion in different strong acids using CFIA via the use of homemade linear array Ayah 5Sx4-ST- 5D solar CFI analyser

View Publication Preview PDF
Publication Date
Sun Jul 02 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Vanadium (V) In Different River Water via the Use of a Homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
...Show More Authors

A new simple sensitive and selective spectrophotometric method has been
developed for the analysis of vanadium(V) in three randomly chosen samples from
river water at different locations by continuous flow injection analysis. The method
based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color
species and the same species was determined using homemade Ayah 6SX1-T-2D
solar cell analyser . Chemical and physical parameters were investigated using the
high intensity of snow white light emitted diode as a source. The linear dynamic
range for the instrument response versus vanadium(V) concentration was 1-200
mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70<

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
...Show More Authors

A newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor

... Show More
View Publication Preview PDF