Preferred Language
Articles
/
jih-1470
Potentiometric Determination of Iodide in Magnesium Fluoride by Iodide Electrode
...Show More Authors

Iodide Ø¢ in samples Ø¢ containing Ø¢ magnesium Ø¢ fluoride Ø¢ was Ø¢ determinedØ¢  Ø¢ by using iodide selective Ø¢ electrode. Ø¢ Detecting Ø¢ the limit for iodide determination

was around Ø¢ 5x1 oآ·5Ø¢ Ø¢ M with a standard Ø¢ deviation Ø¢ ranged Ø¢ from Ø¢ Ø¢Â± 0.3 to آ± 0.6.

QuantitativeØ¢  Ø¢ methodsØ¢  Ø¢ including; standard Ø¢ additionØ¢  Ø¢ method, Ø¢ Potentiometric

titration Ø¢ by using a Gran plot paper for an equivalent Ø¢ point determination and a Ø¢ directØ¢  Ø¢ methodØ¢  Ø¢ wereØ¢  Ø¢ used Ø¢ for Ø¢ the Ø¢ analysis.Ø¢  Ø¢ DissolutionØ¢  Ø¢ of Ø¢ magnesium fluoride samples Ø¢ was investigated Ø¢ in various acids (HCI, HN03, HCI04, and H3P04). Good Ø¢ recovery Ø¢ of Ø¢ iodide Ø¢ was obtained Ø¢ by using Ø¢ hydrochloric and phosphoric Ø¢ acids Ø¢ for dissolution. Interference Ø¢ of Ø¢ uranyl Ø¢ ion and Ø¢ halide Ø¢ ions,

pآ·, cr,Ø¢ and Br- on iodide response was also studied. This method can be used

for the determination of iodide in magnesium Ø¢ fluoride obtained Ø¢ from uranium

metal production.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication
Publication Date
Sun Dec 14 2014
Journal Name
Al-khwarizmi Engineering Journal
Determination of Optimum Welding Parameters for FSW AA2024-T351
...Show More Authors

 

Abstract

Friction stir welding is a relatively new joining process, which involves the joining of metals without fusion or filler materials. In this study, the effect of welding parameters on the mechanical properties of aluminum alloys AA2024-T351 joints produced by FSW was investigated.

Different ranges of welding parameters, as input factors, such as welding speed (6 - 34 mm/min) and rotational speed (725 - 1235 rpm) were used to obtain their influences on the main responses, in terms of elongation, tensile strength, and maximum bending force. Experimental measurements of main responses were taken and analyzed using DESIGN EXPERT 8 experimental design software which was used to develop t

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 16 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of some Drugs using Oxidation Reduction Reactions
...Show More Authors

     A spectrophotometric method is proposed for the determination of some drugs containing amino group such as mesalazine, metoclopramide and dopamine in pharmaceutical formulations. It was simple, precise, accurate, rapid, and based on the oxidation of each drug with chromate as an oxidizing agent in the presence of 1N hydrochloric acid. Then indigo carmine is reacted with residual chromate in the presence of a catalysis factor (sodium oxalate). Increasing in absorbance's value of the color system is proportional to the amount of the three drugs which is measured at the selected wavelength of 610 nm.

The proposed method is obeying Beer's law in the ranges of (1-40, 2-44 and 2-52) ppm for the concentration of

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Journal Of Engineering
Correction Procedure for the Determination of Soil Specific Surface
...Show More Authors

View Publication
Publication Date
Fri Nov 11 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Analytical Methods for Determination of Ketoprofen Drug: A review
...Show More Authors

Ketoprofen has recently been proven to offer therapeutic potential in preventing cancers such as colorectal and lung tumors, as well as in treating neurological illnesses. The goal of this review is to show the methods that have been used for determining ketoprofen in pharmaceutical formulations. Precision product quality control is crucial to confirm the composition of the drugs in pharmaceutical use. Several analytical techniques, including chromatographic and spectroscopic methods, have been used for determining ketoprofen in different sample forms such as a tablet, capsule, ampoule, gel, and human plasma. The limit of detection of ketoprofen was 0.1 ng/ ml using liquid chromatography with tandem mass spectrometry, while it was 0

... Show More
Publication Date
Thu Mar 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Chlorpromazine – HCl Using Potassium Permanganate
...Show More Authors

     Twosimple, sensitive,accurate, and precise spectrophotometric methods have been developed for the determination of chlorpromazine – HCl in pure form and pharmaceutical formulation. The first method involved treatment of cited drug with a measured excess of permanganate in acid medium and the unreacted oxidant was measured at 525 nm. The second method involves the reaction  of the drug with potassium permanganate in the presence of sodium hydroxide to produce a bluish – green  colored manganite which is measurable at 610nm. All the experimental variables affecting the development of the manganite ions were investigatedand conditions were optimized. Working linearity ranges were 5-45 µg.mL-1an

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 14 2016
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Simultaneous determination of time-dependent coefficients and heat source
...Show More Authors

View Publication
Scopus (16)
Crossref (12)
Scopus Crossref
Publication Date
Tue Nov 06 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Contributing Risk Factors to Adult Nephrolithiasis Patients
...Show More Authors

Objectives: To determine the contributing risk factors to adult nephrolithiasis patients.
Methodology: A descriptive study was conducted to determine the contributing risk factors to
Adults nephrolithiasis starting from December 2007 to September 2008. A purposive "nonprobability"
sample of (100) patients with nephrolithiasis was selected of those who were
admitted to the hospitals, attending the Urology Consultation Clinic and Extracorporeal Shock
Wave Lithotripsy Department. The study instrument consists of two parts. The first part is
related to the patients' demographic variables and the second part is constructed to serve the
purpose of the study. The total number of items in the questionnaire was (85) ones.

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Analytical Methods for Determination of Ketoprofen Drug: A review
...Show More Authors

Ketoprofen has recently been proven to offer therapeutic potential in preventing cancers such as colorectal and lung tumors, as well as in treating neurological illnesses. The goal of this review is to show the methods that have been used for determining ketoprofen in pharmaceutical formulations. Precision product quality control is crucial to confirm the composition of the drugs in pharmaceutical use. Several analytical techniques, including chromatographic and spectroscopic methods, have been used for determining ketoprofen in different sample forms such as a tablet, capsule, ampoule, gel, and human plasma. The limit of detection of ketoprofen was 0.1 ng/ ml using liquid chromatography with tandem mass spectrometry, while it was 0.01-

... Show More
View Publication Preview PDF
Crossref (3)
Crossref