Preferred Language
Articles
/
jih-1448
Novel Approach of Oxidative Coupling Reaction with 1-Naphthol of the Simultaneous Metformin Drug Determination in Either Pharmaceutics Formulations or Environmental Samples of Water Using Homemade CFIA- Merging Zones Techniques
...Show More Authors

A newly developed FIA-merging zones spectrophotometric system, the method is rapid, accurate and sensitive for metformin hydrochloride determination through the oxidation of 1- naphthol by sodium hypochlorite and coupling with metformin.HCl in the presence of sodium hydroxide to form a blue soluble ion pair   and this product was determined using homemade CFIA-Merging zones techniques , at 580 nm. Data treatment shows that linear range is (0.5-35) µg/ ml. The optimization conditions for various chemical and physical conditions of [MTF- NaOCl-α-naphthol-NaOH] system were investigated. The LOD was 0.01µg / ml and LOQ 0.1µg/ml from the lowest concentration of the calibration graph with r2% 99.18 and RSD% did not exceed 3%, sample through put 48 sample/h while percentage recovery (Rec.%) were from 97-100% , indicate no interferences of the tablet   excipients. The method   was applied successfully, for estimation of metformin in environmental samples of water and pharmaceutical drugs. Statistical analysis of results was compared, shows the method can be regarded as an alternative analytical way for determining of   metformin. hydrochloride in   bulk and dosage forms samples.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
A new mode for an on-line determination of Pyrocatechol, Resorcinol, and Pyrogallol in pure commercial samples using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer.
...Show More Authors

A new, simple, accurate, fast and sensitive spectrophotometric method has been
developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure
commercial samples by continuous flow injection analysis. The method was based on
the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to
formed a brown colored species which determined using homemade Ayah 3SBGR x3-
3D solar cell flow injection microphotometer. Optimum conditions were obtained
using a high intensity green light emitted diode as an irradiation source
forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for
pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol,

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 03 2023
Journal Name
Iraqi Journal Of Science
Determination of hydroquinone in pure form and pharmaceutical preparations using Batch and FIA-Merging Zone techniques with spectrophotometric detection
...Show More Authors

In this study, a new, rapid and sensitive batch and flow injection-merging zones spectrophotometric methods for the determination of hydroquinone in a pure material and in pharmaceutical preparation were proposed. These methods were based on the oxidative-coupling reaction of HQ with 2,4-dinitrophenylhydazine (DNPH) in the presence of sodium periodate and sodium hydroxide to form a dark brown water slouble dye that is stable and has maximum absorption at 530 nm, graphs of absorbance versus concentration show that Beer's low is obeyed over the concentration rang of 1-40 and 3-300 μg.ml-1 of hydroquinone, with detection limits of 0.162 and 0.510 μg.ml-1 of hydroquinone for batch and FIA methods, respectively. The optimized FIA system is

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Paracetamol by Diazotization and Coupling Reaction with Anthranilic Acid
...Show More Authors

This paper concerned with development of a spectrophotometric method for the determination of paracetamol, based on the diazotisation and coupling reaction with anthranilic acid in basic medium, to form an intense yellow coloured, water-soluble and stable azo-dye which shows a maximum absorption at 421nm. Beer’s law is obeyed over the concentration range of 1.0-10 µg/ml; with molar absorptivity of 2.1772×104 L.mol -1.cm-1 and Sandell’s sensitivity index 6.9446 µg.cm-2. The method has been applied successfully for the determination of paracetamol in pharmaceutical formulation. 

View Publication Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
New sensitive turbidimetric method for determination of losartan potassium in pharmaceutical formulations using flow injection combined with homemade turbidimeter
...Show More Authors

Scopus
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Doxycycline Hyclate by Batch and Reverse Flow Injection Analysis Based on the Oxidative Coupling Reaction with 3-Methyl-2-benzothiazolinone Hydrazone hydrochloride (MBTH)
...Show More Authors

New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Method for the Determination of Tetracycline and Doxycycline by Oxidizing Coupling Reaction with 4-aminoantipyrine
...Show More Authors

 A simple,  sensitive, accurate and low cost effective spectrophotometric method has been developed for the determination of Tetracycline and Doxycycline in pure and pharmaceutical formulations. The method is based on the reaction of methyldopa with 4-aminoantipyren (4-AAP) in presence of potassium ferriecyanide (PFC) in an alkaline medium. Two optimization methods were applied to determine the optimum conditions of oxidizing coupling reaction variables; univariate and design of experiment (DOE) method. The conditions effecting the  reaction; pH, buffer Volume,   reagent concentration, oxidant concentration, type of buffer, order of addition, time of reaction and stability were optimized . Under univariate and design

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
FIA– Spectrophotometric methods for the determination of Naringenin in supplements and urine samples using diazotization coupling reactions
...Show More Authors

Direct FIA methods for estimation of Naringenin (NG) in different samples were proposed. These methods are based on diazotization coupling reactions of two reagents: method (A) p-chloroaniline (PCA) and method (B) procaine hydrochloride (PRH) with NG in basic medium. Yellow dyes with maximum absorption at 416 and 415 nm were formed respectively. Calibration curves were constructed over different NG concentrations, linearity was from 1- 70 and 1- 40 µgmL-1 with detection limits of 0.55 and 0.24 µgmL-1 for (A) and (B) respectively. All analytical variables involved in the FIA procedure were evaluated and optimized. The established methods were successfully applied for the determination of NG in its supplements and u

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Oxidative Coupling Reaction for Micro Trace Analysis of Mebendazol Residual with p-bromoaniline in Presence of n- bromosuccinimide
...Show More Authors

Rapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1.  The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm-1), 0.0099 µg.cm-2 respe

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Oxidative Coupling Reaction for Micro Trace Analysis of Mebendazol Residual with p-bromoaniline in Presence of n- bromosuccinimide
...Show More Authors

Rapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1.  The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref