Preferred Language
Articles
/
jih-1408
Isoscaler and isovector for one body of magnetic dipole transitions of Ba(A=130- 136) isotopes using IBM-1
...Show More Authors

Isoscalar   and  isovector   for  one   body  of  magnetic   dipole transitions    of   even even   Ba   (A=l30-136)  isotopes   have   been calculated using IBM-1 . The present calculations are predicted that the maximum   values    of   magnetic    dipole   reduced   matrix   clement (11  II fr.·Hil lll1         were  found   in  Ba  (A=I30   and  A=136)   for  the

transitions  3!3j   and  42   4jwhile   the  minimum values in the

tr_ansitions  2; 2; and  4! -74; for Ba=l30 and for Ba(A=132  and for Ba(A= 132 and A=I34)  at the transitions of  22!i- The va_.lues

  • ofreduced matrix  element  (I1 .II f (MI) !I li ) in Ba=l36 were appeared

-after the separation  of proton bosons. and neutron bosons at  zt ,3t'

4i and 5    states.. These values were equal to (2.293---.-1.356) IJ.n for

isovector  operators.  The  values  of  B(Ml) doesn't  appears  be.cause there  are  no  transition:s   between  these  energy  states  other  energy states.

l

 
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 06 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Hard palate bone density and thickness determination using CT scan and their relationships with body compositions measured by bioelectrical impedance analysis for Iraqi adult sample
...Show More Authors

Background: This study was conducted to evaluate the hard palate bone density and thickness during 3rd and 4th decades and their relationships with body mass index (BMI) and compositions, to allow more accurate mini-implant placement. Materials and method: Computed tomographic (CT) images were obtained for 60 patients (30 males and 30 females) with age range 20-39 years. The hard palate bone density and thickness were measured at 20 sites at the intersection of five anterioposterior and four mediolateral reference lines with 6 and 3 mm intervals from incisive foramen and mid-palatal suture respectively. Diagnostic scale operates according to the bioelectric impedance analysis principle was used to measure body weight; percentages of body fa

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis of New beta-lactam , 2-thioxoimidazolidin-4-one and Imidazole-5-one Derivatives from thiosemicarbazide and Their Biological Activity Study
...Show More Authors

        New derivatives of thiosemicarbazide were synthesized by reaction of different aromatic aldehydes and ketones with thiosemicarbazide to give schiff-bases 1(a-d) . schiff-bases have been used for synthesized the thioimidazolidine 2(a-d)  by reaction of schiff-bases with ethyl chloroacetatein in presence of anhydrous sodium acetate that transformed part of it in to Beta-lactam 3(a-b) compounds with phenyl acetic acid and thionyl chloride , The compounds 4(a-b) came from the reactor of 4-bromobenzaldehyde with compounds 2(a-b) , as well as reaction of compounds 2(b-d) with methyl iodide and anhydrous potassium carbonate to give 5 (b-d) , then added  hydrazine hydrate formed 6(b-d) , then

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 19 2019
Journal Name
Al-khwarizmi Engineering Journal
Optimization of Material Removal Rate and Temperature in Magnetic Abrasive Finishing Process for Stainless Steel 304
...Show More Authors

The effect of the magnetic abrasive finishing (MAF) method on the temperature rise (TR), and material removal rate (MRR) has been investigated in this paper. Sixteen runs were to determine the optimum temperature in the contact area (between the abrasive powder and surface of workpiece) and the MRR according to Taguchi orthogonal array (OA). Four variable technological parameters (cutting speed, finishing time, working gap, and the current in the inductor) with four levels for each parameter were used, the matrix is known as a L16 (44) OA. The signal to noise ratio (S/N) ratio and analysis of the variance (ANOVA) were utilized to analyze the results using (MINITAB17) to find the optimum condition and identify the significant p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 06 2025
Journal Name
Al-nahrain Journal For Engineering Sciences
The Effect of Magnetic Abrasive Finishing on the Flat Surface for Ferromagnetic and non-Ferromagnetic materials
...Show More Authors

Magnetic Abrasive Finishing (MAF) is an advanced finishing method, which improves the quality of surfaces and performance of the products. The finishing technology for flat surfaces by MAF method is very economical in manufacturing fields an electromagnetic inductor was designed and manufactured for flat surface finishing formed in vertical milling machine. Magnetic abrasive powder was also produced under controlled condition. There are various parameters, such as the coil current, working gap, the volume of powder portion and feed rate, that are known to have a large impact on surface quality. This paper describes how Taguchi design of experiments is applied to find out important parameters influencing the surface quality generated during

... Show More
View Publication
Publication Date
Tue Mar 15 2022
Journal Name
Al-academy
Transformations of the body from traditional expression to subjectivity : Marina Abramivic as a model.
...Show More Authors

The way artists deal with body in their artistic works has had so many forms and methods, whether as an object for their drawings or as a material to create live artistic performances that relate to the idea of correspondence and interaction between different artistic categories such as: drama, dance, and painting as it is the case of the artist Marina Abramovic who has always used her body as an artistic unit to generate meaning and to perform her lively shows.
To go deeper into her career, our work was divided into 3 sections:
The first section was devoted to follow the main artistic stages that her body had gone through, starting with paintings she performed using concepts based on acting, simulation and nudity and ending wi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
A Comparison of Sagittal Sections of Short T1inversion Recovery and T2 Weighted Fast Spin Echo Magnetic Resonance Sequences for Detection of Multiple Sclerosis Spinal Cord Lesions
...Show More Authors

Background: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement,

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 28 2024
Journal Name
World Academy Of Sciences Journal
Serum angiopoietin‑1 as a biomarker of missed miscarriage
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Land Magnetic survey along a profile from Akaz to Rutba town and its applications
...Show More Authors

A land magnetic survey was carried out along regional profile, which is located at the north part of the Iraqi western desert. It starts from al –Qaam City (at north) toward Rutba City (at south) with a total length of 238km. The survey was carried out along the paved road between the two cities, About 113 measuring points were done with inter-station distance of 2 km (for 198 km) and 2 to 5km (for 40km). Two proton magnetometers were used in this survey. One of them is used for base station monitoring, which was fixed as of Salah Aldin field (Akkas). Its readings were used for diurnal corrections. All magnetic measurements were corrected for normal and topographic corrections. The readings were reduced to a certain base level. The resu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Evaluation of the one electron expectation values for different wave function of Be atom
...Show More Authors

The aim of this work is to evaluate the one- electron expectation value from the radial electronic density function D(r1) for different wave function for the 2S state of Be atom . The wave function used were published in 1960,1974and 1993, respectavily. Using Hartree-Fock wave function as a Slater determinant has used the partitioning technique for the analysis open shell system of Be (1s22s2) state, the analyze Be atom for six-pairs electronic wave function , tow of these are for intra-shells (K,L) and the rest for inter-shells(KL) . The results are obtained numerically by using computer programs (Mathcad).

View Publication Preview PDF
Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
ptimization the Parameters of Magnetic Abrasive Process Using Taguchi Method to Improve the Surface Roughness
...Show More Authors

Abstract  

Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment

... Show More
View Publication Preview PDF
Crossref (1)
Crossref