Preferred Language
Articles
/
jih-1380
Spectrophotometric Determination of Chlorpromazine -HCI by Ion -Pair Complex Formation with Acid Dyes
...Show More Authors

A simple, rapid, accurate and sensitive spectrophotometric method is  proposed  for  the  detennination  of chlorprQm<tZine -HCl  in  pwe form  and  in pharmaceutical  formulation. This method is based on the formation.  of ion  assodation complexes  of  dmg   with either  thymol

blue or  bromophenol  blue  in an acidic buffer at pH  values 4.17  and

3.68, respectively.

The ion-pair  complexes  formed exhibit absorption maxima  at 41 Onm for  both  thymol   blue and  bromophenol  blue.  These  complexes· are quantitatively extracted   with chloroform.  The  calibration  graphs  are tmear and obeyed  Bee 's law in a cort.ce n:at_ion range of 50-450fg!ml and   H:}-120)lg/ml  w1th  molar   absorptttvttes  of   L0374xl0    and

1.7613xl03   Lmorcm·1    for  thymol   blue   ,and   bromophenol   blue,

respectively.

Statistical  treatment  of  the  experimental  results   indicated  that  the method   is  precise,  accurate   and   the   procedure    was   successfully applied  to the determination of the bulk drug and its pharrnaceutic;al fpnnulations.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 25 2021
Journal Name
Iraqi Journal Of Science
Determination of some virulence factors of Citrobacter freundii isolated from Iraqi patients
...Show More Authors

      This study included the isolation and identification of Citrobacter freundii from 220 samples collected from inpatients and outpatients suffering from urinary tract infection (UTI) and identified at the laboratory of the General Samarra Hospital in Samarra City, Iraq. The study was conducted to investigate some of the virulence factors produced by C. freundii. The results showed that 67 isolates were  belonging to the C. freundii, with a rate of  30.45%. Twenty eight samples were from inpatients (41.8%)  and 39 samples were from outpatients. The bacterial identification was based on cultural and biochemical tests and confirmed by using VIT

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Materials Letters
Determination of third order susceptibility of carbon quantum dots at different concentrations
...Show More Authors

The nonlinear refractive (NLR) index and third order susceptibility (X3) of carbon quantum dots (CQDs) have been studied using two laser wavelengths (473 and 532 nm). The z-scan technique was used to examine the nonlinearity. Results showed that all concentrations have negative NLR indices in the order of 10−10 cm2/W at two laser wavelengths. Moreover, the nonlinearity of CQDs was improved by increasing the concentration of CQDs. The highest value of third order susceptibility was found to be 3.32*10−8 (esu) for CQDs with a concentration of 70 mA at 473 nm wavelength.

View Publication
Scopus Clarivate Crossref
Publication Date
Sat Oct 14 2023
Journal Name
Environmental Monitoring And Assessment
The technique of arsenic elimination from contaminated soil with enhanced conditions by electro-kinetic remediation
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Bulletin Of National Institute Of Health Sciences
Using of Propolis on the treated rats induced with Polysystic ovarian syndrome by Litrozol drug
...Show More Authors

View Publication
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Molecular diagnosis of E.coliO157:H7 Which Isolated from Children with Diarrhea by using Multiplex PCR
...Show More Authors

A total of 96 stool samples were collected from children with bloody diarrhea from two hospitals in Baghdad. All samples were surveyed and examined for the presence of the Escherichia coli O157:H7 and differentiate it from other Non -Sorbitol Fermenting Escherichia coli (NSF E. coli). The Bacterial isolates were identifed by using morphological diagnostic methods, Samples were cultured on liquid enrichment medium, incubated at 37C? for 24 hrs, and then cultured on Cefixime Tellurite -Sorbitol MacConkey Agar (CT- SMAC). 32 non-sorbitol fermenting bacterial isolates were obtained of which 11 were identified as Escherichia coli by using traditional biochemical tests and API20E diagnostic system without differentiation between

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 03 2016
Journal Name
Iraqi Medical Journal
EVALUATION OF PATIENTS WITH CARPAL TUNNEL SYNDROME TREATED BY MINIMAL PALMAR INCISION (A PRELIMINARY STUDY)
...Show More Authors

Background : Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of upper extremities and Open carpal tunnel release is the most frequent surgical procedure and the gold standard for cases that do not respond to conservative treatment. Aims :This study is used to evaluate the functional outcome of limited palmar mini-incision of carpal tunnel release. This study aims to determine the safety and symptomatic and functional efficacy of median nerve decompression with limited incision in carpal tunnel syndrome surgery. Patients and methods:Carpal tunnel release with a 1.5-2 cm limited palmar incision was performed on 20 patients. Patients were evaluated initially at one month after treatment according to symptom severity

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Detecting Keratoconus by Using SVM and Decision Tree Classifiers with the Aid of Image Processing
...Show More Authors

 Researchers used different methods such as image processing and machine learning techniques in addition to medical instruments such as Placido disc, Keratoscopy, Pentacam;to help diagnosing variety of diseases that affect the eye. Our paper aims to detect one of these diseases that affect the cornea, which is Keratoconus. This is done by using image processing techniques and pattern classification methods. Pentacam is the device that is used to detect the cornea’s health; it provides four maps that can distinguish the changes on the surface of the cornea which can be used for Keratoconus detection. In this study, sixteen features were extracted from the four refractive maps along with five readings from the Pentacam software. The

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Reduction of Noise and Vibration of Spur Gear by Using Asymmetric Teeth Profiles with Tip Relief
...Show More Authors

Reduction of noise and vibration in spur gear experimentally by using asymmetric teeth profiles with tip relief was presented. Both of classical (symmetric) and asymmetric (with and without tip relief) spur gears are used in this work. Gear test rig was constructed to achieve torsional vibration measuring, and two modified cutters are designed and manufactured to achieve tooth profile modifications. First to cut asymmetric gear tooth with pressure angles (14.5o/25 o) without tip relief for loaded and unloaded tooth sides respectively, and second to cut asymmetric gear tooth with pressure angles (14.5o/25 o) for loaded and unloaded tooth sides respectively with tip relief to ach

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Treatment of Patients with Vitiligo by Intradermal Pricking of Vitiligenous Skin Using Sharp and Blunt Needle
...Show More Authors

View Publication
Crossref
Publication Date
Mon Aug 05 2024
Journal Name
Pharmacia
A validated spectrophotometric analysis for simultaneous estimation of vincristine sulfate and bovine serum albumin in pure preparations using Vierordt’s method
...Show More Authors

The novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LO

... Show More
View Publication
Scopus Clarivate Crossref