Preferred Language
Articles
/
jih-1368
Expermental Comparison For The Performance of Circular And Square Solar Cell
...Show More Authors

An    Experimental     comparison     between     the     current-voltage

characteristic and    the  efficiency    conversion from  solar  to  electric energy   were studied  for square  and circular  single crystal  silicon  solar

cell of equal area (35.28  cm2)  . The results show  that the solar shape is

an  important factor  in  calculating the  current-voltage characteristics and  efficiency of  the  solar  cell.  It was  shown   that  the  performance efficiency   of  the  square  cell  is  greater  by 8.19%  than  that    for  the circular cell of  equal area.

Although   the  packing  factor  for  the  square  cells  in  the  solar  panel

.reached  96%  compared   with  79%  for  that  for  circular   cells  panel panel, the final cost for the circular cel1s panel is less than square cells panel.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Algebraic Statistics
The effect of compound exercises for the arm least used in developing the accuracy of the passing skill of the handball for ages (15-17) years
...Show More Authors

Publication Date
Sun Jul 03 2016
Journal Name
Journal Of Educational And Psychological Researches
The Impact of the Constructive Scientific Stations Strategy on Achievement and Mind Habits for The Fourth Scientific students in biology
...Show More Authors

The study aimed at ideutifying the impact of scieutific skills in strategy and liabits of mind amony stueuts in tenth grade . The study demanded to choose a sampie that coutaiun (42) student of the fourth grade of the secondary school who were dirided into tow groups , the first is experimental studied according to scieutific skill strategy , and the other controlling , studied according to the  usualway . An achievement test  has been taken that adopted  staudard for mind skills as research tools that are applid after ascertaining  sincerity proved at the end of the experiment .The study has reached to the conclusion that there are statistically significant differnces in farour of the experiment group in both

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Internal control and its role in the reform of the tax work: Applied research in the General Commission for Taxes
...Show More Authors

That internal control is particularly important in improvingperformance and tax reform، they play an important role in the regularity ofwork and development and the anti corruption and activating the decisionsand tax legislation، as contained in the organizational plan and the means،procedures and components designed from which to ensure a policy andimplementation plans The research aims to review the reality of the internalcontrol in the General Commission for Taxes and stand on the deficiencies init, with the strengthening of the role of internal control in the GeneralAuthority for taxes based on the laws and regulations and by using modernmeans to work as well as developing the performance of employees in thebody، including helpin

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 14 2023
Journal Name
Iete Journal Of Research
Performance Enhancement of VLC-NOMA Employing Beamforming Function based vehicle-to-multivehicle Communication system
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Serviceability performance of high-strength concrete flexural members with internally unbonded post-tensioning strands
...Show More Authors

View Publication
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Roughness Effect on Thermo-Elasto-Hydrodynamic Performance of a 170ᵒ -Arc Partial Journal Bearing
...Show More Authors

In the current analysis, the effects of circumferential scratches along the inner surface of a 170ᵒ -arc partial journal bearing has been numerically investigated. Their impact on the thermo-elasto-hydrodynamic performance characteristics, including maximum pressure, temperature, deformation, and stress, has been examined thoroughly. The ANSYS Fluent CFD commercial code was employed to tackle the iterative solution of flow and heat transfer patterns in the fluid film domain. They are then applied to the ANSYS Static Structure solver to compute the deformation and stress resulted in the solid bearing zone. A wide range of operating conditions has been considered, including the eccentricity ratio ( ) and scratch depth (

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Impact of Physical Work Environment upon Nurses’ Job performance in Al-Nassiryah City Hospitals
...Show More Authors

AbstractObjectives: The work environment has an impact on the performance of nurses, as well as to determine the relationship between the work environment and the performance of nurses.Research methodology: A descriptive analytical study was designed for the impact of the work environment on the performance of nurses' jobs in the hospitals of the city of Nasiriyah. The study began in the period from May 15, 2022 to 1 November, 2022. The non-probability (purposive) sample consisted of (410) nurses working in the city center hospitals. Nasiriyah, they were chosen based on the study criteria, and after obtaining approval from them. The data was collected using the questionnaire, which consi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improving Treatment Performance of Dissolved Air Flotation System by Using Ionic Liquids as Surfactants
...Show More Authors

The effect of three ionic liquids viz., 1-hexyl-3-methylimidazolium tetrafluoroborate (ILE), 1-hexyl-3-metylimidazolium hexafluorophosphate (ILF) and 1-octyl-3-methylimidazolium tetrafluoroborate (ILG) when used as surfactants on the performance of dissolved air floatation (DAF) was investigated.

   Experiments were conducted at a temperature of 30-35 ºC, 10ppm ferric chloride as coagulant, 50% recycle ratio, pH 8, and 10 minutes treatment time  to find oil and grease (OG) and turbidity removal efficiencies at saturation pressure (2-6) bar.

ILs were used at concentration of 50 µl/liter of treated water in two positions in DAF system; the saturation vessel and the treatment tank. The performance using ILs

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Performance of composite unprotected steel Beam-deck floor exposed to high temperature (fire flame)
...Show More Authors

An experimental program was conducted to determine the residual of composite Steel Beams-Reinforced Concrete (SB-RC) deck floors fabricated from a rolled steel beam topped with a reinforced concrete slab, exposed to high temperatures (fire flame) of 300, 500, and 700ºC for 1 hour, and then allowed to cool down by leaving them in the lab condition to return to the ambient temperature. The burning results showed that, by exposing them to a fire flame of up to 300ºC, no serious permanent deflection occurred. It was also noticed that the specimen recovered 93% of 19.2 mm of the deflection caused by burning. The recovered deflection of burned composite SB-RC deck floor at 500ºC was 40% of 77.9 mm of the deflection caused by burning with a res

... Show More
View Publication Preview PDF