Modification of gas chromatographic technique for the separation and determination of methyl ethoy silane compounds which were synthesized by the addition of absolute ethanol to methyl chlorosilane compounds have been elaborated experimentally. The addition of absolute dry ethanol to methyl chlorosilane compounds in the presence of a dry stream of nitrogen gas led to sweep out the liberated HCl gas. This method was found to be the suitable method for the preparation of methyl ethoxy silane compounds. The optimum parameter selected after careful and precise studies was between 20 – 30 ml \ min to carrieir gas flow rate, while applied temperatures of detector and injection part were 250 °C and 225 °C respectively. The results showed that suitable chromatographic column for the separation of methyl chloro silane compounds is 50% [5% dioctyl phthalate ] + 50% [10% OV- 101 ] .While 10 % OV – 101 column was found to be the best for the separation of methyl ethoxysilane compounds . Accordingly , a linear relationship for the calibration curve between concentration and peak area is achieved for methyl chlorosilane and methyl ethoxysilane . Correlation coefficients here ranged between 1 – 0.9991. The results of percentage RSD alotarned for the methyl chlorosilane and methyl ethoxysilane were 0.512.08 and 0.053-1.37 respectively.
This paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi
... Show MoreA simple, precise and accurate spectrophotometric method has been developed for simultaneous estimation of sulfanilamide and furosemide in their mixture by using first and second order derivative method in the ultraviolet region. The method depends on first and second derivative spectrophotometry, with zero-crossing and peak to base line and peak area measurements. The first derivative amplitudes at 214, 238 and 266 nm were selected for the assay of sulfanilamide and 240, 260, 284, 314 and 352 nm for furosemide. Peak area at 201222, 222-251 and 251-281 nm selected for estimation of sulfanilamide and at 229-249, 249270, 270-294, 294-333 and 333-382 nm for furosemide. The second derivative amplitudes at 220, 252 and 274 nm for sulfanilamid
... Show MoreA steganography hides information within other information, such as file, message, picture, or video. A cryptography is the science of converting the information from a readable form to an unreadable form for unauthorized person. The main problem in the stenographic system is embedding in cover-data without providing information that would facilitate its removal. In this research, a method for embedding data into images is suggested which employs least significant bit Steganography (LSB) and ciphering (RSA algorithm) to protect the data. System security will be enhanced by this collaboration between steganography and cryptography.
Pseudomonas aeruginosa was isolated from various clinical samples included urine, sputum, stool, ear, wound & burn swabs. Detection of the ability of local isolates to produce staphylolysin enzyme was studied, on Tryptic soya agar + 0.2% (wt./vol.) of heat killed Staphylococcus. aureus at temperature 100oC. medium and the diameters of lysis zone ranged from 5-22mm, then the isolate P16 was chosen to extract staphylolysin A (LasA) and its specific activity reaches 8.59 unit /mg protein, whi1e the isolate P5 was chosen to extract staphylolysin D (LasD) where it's specific activity reaches 0.66 unit /mg protein since the two isolates were the most production of enzyme. Staphylolysin enzyme was extracted by cooling centrifugation and par
... Show MoreWestiellopsis prlifica was exposed to 1, 2, 3, 5, 7 and 10 ppm from both lead & Cadmium, in order to measure their capacity to remove these metals from the polluted aquatic environment and to study its ability to tolerant them. The algae were grown under optimum conditions.
Westiellopsis prlifica had the ability to remove the lead with percentages about 31.57, 54.42, 62.35, 61.8, 57.02 and 68.34% for the concentrations 1, 2, 3, 5, 7 and 10 ppm, respectively, but it was found that these percentages were be better in the last day of the experiment for some of the concentrations 1, 2 and 3 ppm, While the tolerant of it to lead was up to the concentration 10 ppm.
Westiellopsis prlifica appears ability to remove Cadmium with percent
In this study, detection of uricase production from Pseudomonas aeruginosa
isolates was done by applying colorimetric method, Uricase was purified from the
most potent isolate by precipitation using ammonium sulphate (80% saturation) then
purification was achieved using DEAE –Cellulose ion exchange and Sepharose 6B
gel filtration chromatography column, 16.4% of total enzyme was recovered with
specific activity 2337.5U/mg and 22.21folds of purification. Characterization of
uricase involved detection of optimal conditions for uricase activity, the maximal
activity was obtained at temperature 45ºC,while uricase appeared to be stable at
40ºC. Uricase showed optimal activity at pH 9 while pH stability was in the
—Medical images have recently played a significant role in the diagnosis and detection of various diseases. Medical imaging can provide a means of direct visualization to observe through the human body and notice the small anatomical change and biological processes associated by different biological and physical parameters. To achieve a more accurate and reliable diagnosis, nowadays, varieties of computer aided detection (CAD) and computer-aided diagnosis (CADx) approaches have been established to help interpretation of the medical images. The CAD has become among the many major research subjects in diagnostic radiology and medical imaging. In this work we study the improvement in accuracy of detection of CAD system when comb
... Show More