Preferred Language
Articles
/
jih-1257
Fixation of Efficient Method for Separation and Analysis of Alkyl Al koxy Silan Compounds by Gas Chromatography
...Show More Authors

       Modification of gas chromatographic technique for the separation and determination of methyl ethoy silane compounds which were synthesized by the addition of absolute ethanol to methyl chlorosilane compounds have been elaborated experimentally.  The addition of absolute dry ethanol to methyl chlorosilane compounds in the presence of a dry stream of nitrogen gas led to sweep out the liberated HCl gas. This method was found to be the suitable method for the preparation of methyl ethoxy silane compounds. The optimum parameter selected after careful and precise studies was between 20 – 30 ml \ min to carrieir gas flow rate, while applied temperatures of detector and injection part were 250 °C   and 225 °C respectively. The results showed that suitable chromatographic column for the separation of methyl chloro silane compounds is 50% [5% dioctyl phthalate ] + 50% [10% OV- 101 ] .While 10 % OV – 101 column was found to be the best for the separation of methyl ethoxysilane compounds . Accordingly  , a linear relationship for the calibration curve between concentration and peak area is achieved for methyl chlorosilane and methyl ethoxysilane . Correlation coefficients here ranged between 1 – 0.9991. The results of percentage RSD alotarned for the methyl chlorosilane and methyl ethoxysilane were 0.512.08 and 0.053-1.37 respectively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Curtin University
Gas hydrates investigation: flow assurance for gas production and effects on hydrate-bearing sediments
...Show More Authors

This thesis was aimed to study gas hydrates in terms of their equilibrium conditions in bulk and their effects on sedimentary rocks. The hydrate equilibrium measurements for different gas mixtures containing CH4, CO2 and N2 were determined experimentally using the PVT sapphire cell equipment. We imaged CO2 hydrate distribution in sandstone, and investigated the hydrate morphology and cluster characteristics via μCT. Moreover, the effect of hydrate formation on the P-wave velocities of sandstone was investigated experimentally.

Preview PDF
Publication Date
Mon Apr 28 2025
Journal Name
Chemical Papers
New chemiluminometric method for the determination of azithromycin in a continuous flow injection analysis system
...Show More Authors

A novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Determination of some characteristics of comet’s gases by photometry method for comet Hyakutake
...Show More Authors

The present paper focuses on the study of some characteristics of
comets ions by photometry method which represent by CCD camera
which it provide seeing these images in a graded light. From 0-255
when Zero (low a light intensity) and 255 (highlight intensity). These
differences of photonic intensity can be giving us a curve which
appear from any line of this image.
From these equations the focus is concentrating on determine the
temperature distribution, velocity distribution, and intensity number
distribution which is give number of particles per unit volume.
The results explained the interaction near the cometary nucleus
which is mainly affected by the new ions added to the density of the
solar wind, th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Measurement of radon and thoron concentrations of soil- gas in Al-Kufa city using RAD-7 detector
...Show More Authors

This work represents the set of measurements of radon and thoron concentrations levels of soil-gas in Al-Kufa city in Iraq using electric Radon meter (RAD-7). Radon and thoron concentration were measured in soil-gas in 20 location for three depth of (50, 100 and 150) cm.
The results show that the emanation rate of radon and thoron gas varied from location to anther, depending on the geological formation. The Radon concentration in soil has been found to vary from (12775±400) Bq/m3 at 150 cm depth in location (sample K2) to (41.45±17) Bq/m3, for depth 150 cm in location (sample K20). The thoron concentration in soil has been found to vary from (198±8.5) Bq/m3 at 150 cm depth in location samples (K1 & K2) to undetected in the mos

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2017
Journal Name
Catalysis Science & Technology
Decomposition of selected chlorinated volatile organic compounds by ceria (CeO 2)
...Show More Authors

Chlorinated volatile organic compounds (CVOCs) are toxic chemical entities emitted invariably from stationary thermal operations when a trace of chlorine is present. Replacing the high-temperature destruction operations of these compounds with catalytic oxidation has led to the formulation of various potent metal oxides catalysts; among them are ceria-based materials. Guided by recent experimental measurements, this study theoretically investigates the initial steps operating in the interactions of ceria surface CeO2(111) with three CVOC model compounds, namely chloroethene (CE), chloroethane (CA) and chlorobenzene (CB). We find that, the CeO2(111) surface mediates fission of the carbon–chlorine bonds in the CE, CA and CB molecules via mo

... Show More
Publication Date
Sat Jun 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prediction and Correlations of Residual Entropy of Superheated Vapor for Pure Compounds
...Show More Authors

Prediction of accurate values of residual entropy (SR) is necessary step for the
calculation of the entropy. In this paper, different equations of state were tested for the
available 2791 experimental data points of 20 pure superheated vapor compounds (14
pure nonpolar compounds + 6 pure polar compounds). The Average Absolute
Deviation (AAD) for SR of 2791 experimental data points of the all 20 pure
compounds (nonpolar and polar) when using equations of Lee-Kesler, Peng-
Robinson, Virial truncated to second and to third terms, and Soave-Redlich-Kwong
were 4.0591, 4.5849, 4.9686, 5.0350, and 4.3084 J/mol.K respectively. It was found
from these results that the Lee-Kesler equation was the best (more accurate) one

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Second Engineering Scientific Conference
SEPARATION OF ALKALOIDS FROM PLANTS BY BULK LIQUID MEMBRANE TECHNIQUE USING ROTATING DISCS CONTACTOR
...Show More Authors

This paper describes the transport of Alkaloids through Rotating Discs Contactor (RDC) using n-decane as a liquid membrane. The transport of Pelletierine Alkaloid from a source phase through bulk liquid membrane to the receiving phase has been investigated. The general behaviour of Pertraction process indicates that% Extraction of pelletierine Alkaloid increased with increase in the number of stages and the agitation speed but high agitation speed was not favoured due to the increased risk of droplet formation during the operation. The pH of source and receiving phases were also investigated. The effect of organic solvent membrane on the extraction of Pelletierine was evaluated using ndecane, n-hexane and methyl cyclohexane. The results sho

... Show More
Publication Date
Mon Apr 01 2019
Journal Name
2019 International Conference On Automation, Computational And Technology Management (icactm)
Multi-Resolution Hierarchical Structure for Efficient Data Aggregation and Mining of Big Data
...Show More Authors

Big data analysis is essential for modern applications in areas such as healthcare, assistive technology, intelligent transportation, environment and climate monitoring. Traditional algorithms in data mining and machine learning do not scale well with data size. Mining and learning from big data need time and memory efficient techniques, albeit the cost of possible loss in accuracy. We have developed a data aggregation structure to summarize data with large number of instances and data generated from multiple data sources. Data are aggregated at multiple resolutions and resolution provides a trade-off between efficiency and accuracy. The structure is built once, updated incrementally, and serves as a common data input for multiple mining an

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
A Factorial Study for separation anxiety in students, of Baghdad City
...Show More Authors

A Factorial Study for separation anxiety in students, of Baghdad City

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (2)
Crossref