Inhibitory effect of Lactobacillus plantarum was studied against Escherichia coli O157:H7 in minced beef , as well as the effect of some Spices ( Garlic , Cloves and Black Pepper ) was studied against this bacteria . Plate count method was used to estimate the viable cells of E. coli O157:H7 in the treated meat samples for incubation periods( 0 , 24 and 48) h. Results showed that Lactobacillus plantarum had inhibitory effect against E. coli O157:H7 , when reducing the number of cells after 24, 48 h., and reached to Zero after (24) h. As well as Spices in this study had inhibitory activity against E. coli O157:H7 .Garlic had the highest inhibitory effect compared with Cloves and Black Pepper. The synergistic inhibitory effect of the combination of Lactobacillus plantarum and Spices ( Garlic , Cloves and Black Pepper ) separately were studied against E. coli O157:H7 in the minced beef using the same method of counting . Results showed that the combination of Lactobacillus plantarum and spices had a synergistic inhibitory effect against E. coli O157:H7. The synergistic Inhibitory effect of Lactobacillus plantarum and garlic in (24)h. incubation period was higher than the effect of other spices.
The adsorption ability of Iraqi initiated calcined granulated montmorillonite to adsorb Symmetrical Schiff Base Ligand 4,4’-[hydrazine-1, 2-diylidenebis (methan-1-yl-1-ylidene)) bis (2-methoxyphenol)] derived from condensation reaction of hydrazine hydrate and 4-hydroxy-3-methoxybenzaldehyde, from aqueous solutions has been investigated through columnar method.The ligand (H2L) adsorption found to be dependent on adsorbent dosage, initial concentration and contact time.All columnar experiments were carried out at three different pH values (5.5, 7and 8) using buffer solutions at flow rate of (3 drops/ min.),at room temperature (25±2)°C. The experimental isotherm data were analyzed using Langmuir, Freundlich and Temkin equations. The monol
... Show MoreTwo well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show More