Preferred Language
Articles
/
jih-1149
Variation of Charging Parameters on A dust Grain in Laboratory Plasma by Using Orbital-Motion Limited Theory

       Using orbit- motion limited theory, as the exact theory in calculating the ion and electron current in dusty plasma, the variations of charge number on a dust grain in Ar-plasma are studied by changing various charging parameters. Most of dependences of charge number on plasma parameters in this paper take into account the close packed effect.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Spectroscopic Diagnosis of Cobalt Plasma Produced by OES Technique and Influence of Applied Voltage on Plasma Parameters

     In this work, plasma system that operates at vacuum was designed and built using a sheet of cobalt metal for the purpose of diagnosing plasma and measuring its parameters, as it is very important to know the processes that accompany plasma generation and are closely related to them, including the electron density in the plasma and its temperature. The spectroscopic diagnosis was done by optical emission spectroscopy (OES) which relies on the calculation of the optical radiation emitted by the plasma to describe plasma parameters in the chemical, molecular, and ionic radiator's near environment, and applied to cobalt metal at vacuum D.C high voltage power supply. The results showed the rise of spectral lines intensity with increa

... Show More
Scopus (4)
Crossref (4)
Scopus Crossref
View Publication Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
The Thermal Properties of Gliding arc Plasma Produced by Laboratory Reverse Vortex Flow System

A low-cost reverse flow plasma system powered by argon gas pumping was built using homemade materials in this paper. The length of the resulting arc change was directly proportional to the flow rate, while using the thermal camera to examine the thermal intensity distribution and demonstrating that it is concentrated in the centre, away from the walls at various flow rates, the resulting arc's spectra were also measured. The results show that as the gas flow rate increased, so did the ambient temperature. The results show that the medium containing the arc has a maximum temperature of 34.1 ˚C at a flow rate of 14 L/min and a minimum temperature of 22.6 ˚C at a flow rate of 6 L/min.

Crossref
View Publication Preview PDF
Publication Date
Thu Aug 01 2013
Journal Name
Journal Of The College Of Basic Education
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Effect of electrode separation in magnetron DC plasma sputtering on grain size of gold coated samples

In this work, an experimental research on a low voltage DC magnetron plasma sputtering (0-650) volt is used for coating gold on a glass substrate at a constant pressure of argon gas 0.2 mbar and deposition time of 30 seconds. We focused on the effects of operating conditions for the system such as, electrode separation and sputtering current on coated samples under the influence of magnetic flux. Electron temperature and electrons and ions densities are determined by a cylindrical single Langmuir probe. The results show the sensitivity of electrode separation lead to change the plasma parameters. Furthermore, the surface morphology of gold coated samples at different electrode separation and sputtering current were studied by atomic forc

... Show More
Crossref (3)
Crossref
View Publication Preview PDF
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Journal Of Science
Influence of Fe2O3 Dust Particles on the Plasma Characteristics of D.C Sputtering System

    This work is an experimental study conducted to study the effects of iron oxide dust particles (Fe2O3) on the characteristics of DC discharge plasma in argon gas under vacuum. Electron temperature ( ) and electron density (ne) were calculated by Boltzmann plots and Stark broadening, respectively. The results show that both the electron density and plasma frequency ( ) increased with the operating pressure. While,  and Debye length ( ) decreased with pressure. The glow discharge is more stable with the Fe2O3-dust particles; all dust plasma parameters have lower values  than those of the dust-free plasma.

Scopus (2)
Crossref (1)
Scopus Crossref
View Publication Preview PDF
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Effect of Fe2O3 Nanoparticles Dust on the D.C Plasma Characteristics with Mirror Magnetron

     In this paper, the effect of iron oxide nanoparticles dust (Fe2O3 NPs) on the parameters of DC electric discharge plasma under vacuum in argon gas was studied with the presence of a mirror magnetron behind the electrodes (cathode and anode) at constant pressure and with different amounts of Fe2O3 nanoparticles. Calculations presented a reduction of the plasma emission intensity with the NPs content. Both the plasma density (calculated by Stark's broadening method) and the mean electron temperature (calculated using Boltzmann's equation) decreased with increasing the Fe2O3 nanoparticles dust content, which indicates clearly the effect of dust density on restricting

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Study of Laser Propagation Parameters in the Underdense Plasma Region Using a Two Dimensional Simulation Code

The propagation of laser beam in the underdense deuterium plasma has been studied via computer simulation using the fluid model. An appropriate computer code “HEATER” has been modified and is used for this purpose. The propagation is taken to be in a cylindrical symmetric medium. Different laser wavelengths (1 = 10.6 m, 2 = 1.06 m, and 3 = 0.53 m) with a Gaussian pulse type and 15 ns pulse widths have been considered. Absorption energy and laser flux have been calculated for different plasma and laser parameters. The absorbed laser energy showed maximum for  = 0.53 m. This high absorbitivity was inferred to the effect of the pondermotive force.

View Publication Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Journal Of Science
Spectroscopy Diagnostic of Laser Intensity Effect on Zn Plasma Parameters Generated by Nd: YAG Laser

      The creation and characterization of laser-generated plasma are affected by laser irradiance, representing significant phenomena in many applications.  The present work studied the spectroscopy diagnostic of laser irradiance effect on Zn plasma features created in the air by a Q-switched Nd: YAG laser at the fundamental wavelength (1064nm).  The major plasma parameters (electron temperature and electron density) have been measured using the Boltzmann plot and the Stark broadening methods.  The value of electrons temperature ranged from 6138–6067 K, and the electron density in the range of 1.4×1018 to 2×1018 cm-3, for laser irradiance range from 2.1 to 4.8×108 (W/cm2

... Show More
Scopus (8)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Study on the Electrical Characteristics of Generating Plasma by Using Different Target Sources

In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur

... Show More
Scopus (11)
Crossref (5)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Tue Aug 31 2021
Journal Name
Iraqi Journal Of Science
Spectroscopic Analysis of Clove Plasma Parameters Using Optical Emission Spectroscopy

     In the current study, the emission spectra generated from clove were measured under normal atmospheric pressure with different laser energies. Clove is used as a source of essential oil in herbal medicine, in particular as a dynamic analgesic oil in dental and other diseases. For aromatherapy, Antiseptic, antiviral, and antimicrobial agents are also packaged with cloves. Compounds that reduce inflammation tend to battle sore throats, cold, and cough as they display so many advantages. The measured spectrum reveals distinctive lines of clove’s chemical elements. X-ray fluorescent (XRF) and atomic absorption spectrometry (AAS) were used to measure the spectrum generated or absorbed by detecting the presence of va

... Show More
Scopus (9)
Crossref (4)
Scopus Crossref
View Publication Preview PDF