Preferred Language
Articles
/
jih-112
Spectrophotometric Determination of Sulfathiazole Using 2,4 –dinitrophenylhydrazine as Coupling Reagent
...Show More Authors

A rapid, sensitive and selective spectrophotometric method was developed for determination of sulfathiazole (STHZ) in aqueous solution. The method is based on the  oxidative coupling reaction with 2,4-dinitrophenylhydrazine (2,4-DNPH) in a basic medium (pH 10.9) in the presence of  potassium periodate to produce an intense orange colour, soluble in water , stable product and absorbs at 492 nm. Beer's law was in the linear range 2.0-28.0 μg/ml of sulfathiazole, the molar absorptivity, Sandellʼs sensitivity index and detection limit were 1.1437 ×104 liter. mol-1.cm-1,0.0223 μg.cm-2 and 0.1274 μg/ml respectively. The RSD value was  0.75 - 1.12 % depending on the concentration. This method was applied successfully to the determination of sulfathiazole veterinary injection liquid solution (bio prime) with average recovery of not less than  100.38  %.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Scholars' Press
Liquid Crystals of 2,4-Substituted-1,3-Thiazole Derivatives
...Show More Authors

A new compounds of 2,4-substituted-1,3- thiazole containing amines [I] and [II], Schiff bases [IV] and [V], amides [VI]-[X],esters [XI] - [XIII], thiazolidinones [XIV]-[XVIII] and 1,3-oxazepines [XIX]-[XXV] were Synthesized and characterized by melting points, FTIR spectroscopy, elemental analysis, 1HNMR,13CNMR, dept135and Mass spectroscopy. The liquid crystalline properties of the synthesized compounds were verified by using hot-stage polarizing optical microscopy (POM) and differential scanning calorimeter (DSC). The compound [I] was found to be nematic textures (N). The first series of this study [II]n display only enantiotropic nematic phase when n=1-5 while the compounds with n =6-8 display two mesophasese smectic C(SmC) and nematic ph

... Show More
Publication Date
Tue Apr 20 2021
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Weak Pseudo – 2 – Absorbing Submodules And Related Concepts
...Show More Authors

      Let  R  be a commutative ring  with identity  and  E  be a unitary left  R – module .We introduce  and study the concept Weak Pseudo – 2 – Absorbing submodules as  generalization of weakle – 2 – Absorbing submodules , where a proper submodule  A of  an  R – module  E is  called  Weak Pseudo – 2 – Absorbing  if   0 ≠ rsx   A   for  r, s  R , x  E , implies that  rx   A + soc ( E ) or  sx  A + soc (E)  or   rs  [ A + soc ( E ) E ]. Many basic  properties, char

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of some Variables on the Formulation of Captopril as Tablets Shaymaa Nazar Al – Sammarrai
...Show More Authors

Captopril is an angiotensin converting enzyme inhibitor (ACEI) used to treat hypertension,
congestive heart failure, and myocardial infraction.
The only dosage form available for captopril is the plain tablet in strength of 12.5,25,50 and 100mg
tablet.
This investigation is concerned with factors affecting the formulation of captopril as a plain
tablet dosage form of 50mg. Many trials were made to prepare satisfactory tablets for the drug by
using wet – granulation methods with various additives. It was found that poly vinyl pyrrolidone
(P.V.P.) as binder gave the most satisfactory tablets. At the same time a shorter disintegrantion time
and slower dissolution rate were obtained with the addition of starch

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Reducing the Mutual Coupling of Cylindrical Circular Microstrip Antennas (CCMAs) Array Using EBG Structure
...Show More Authors

A theoretical study to design a conformal microstrip antennas was introduced in this work. Conformal microstrip antennas define antennas which can be conformed to a certain shape or to any curved surface. It is used in high-speed trains, aircraft, defense and navigation systems, landing gear and various communications systems, as well as in body wearable. Conformal antennas have some advantages such as a wider-angle coverage compared to flat antennas and low radar cross-sectional (RCS) and they are suitable for using in Radome. The main disadvantage of these antennas is the narrow bandwidth. The FDTD method is extremely useful in simulating complicated structures because it allows for direct integration of Maxwell's equations depending o

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
...Show More Authors

This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) b

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Jan 12 2021
Journal Name
Pollution Research
DETERMINATION OF ANILINE IN WASTEWATER BY CLOUDPOINT EXTRACTION FOLLOWED BY HPLC USING 8-HYDROXYQUINOLINE AS A DERIVATIZATION AGENT
...Show More Authors

A procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using t

... Show More
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
CFIA-Turbidimetric and Photometric Determination of Vitamin B9 (Folic acid) Using LEDs as a Source of Irradiation and Two Solar Cells as an Energy Transducer
...Show More Authors

A specific, sensitive and simple method was used for the determination of: vitamin B9 (Folic acid) in pure and pharmaceutical formulations using continuous flow injection analysis. The method is based on formation of ion pair compound between folic acid and ammonium molybdate in an aqueous medium to obtain a gray precipitate complex, using homemade; Ayah-6SX1-ST-2D solar cell CFI Analyzer. Optimum parameters was studied to increase the sensitivity for developed method. The linear range for the calibration graph was 0.01-0.6 mMol.L-1 of vitamin B9 and LOD was 131.994 ng/sample with correlation coefficient ( r ) of 0.9810, RSD% was lower than 0.1%, (n=9) for the determination of vitamin B9 at concentration (0.07and 0.5) mMol.L-1 respectiv

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Doxycycline Hyclate by Batch and Reverse Flow Injection Analysis Based on the Oxidative Coupling Reaction with 3-Methyl-2-benzothiazolinone Hydrazone hydrochloride (MBTH)
...Show More Authors

New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Apr 25 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DETERMINATION OF SOME TRACE ELEMENTS IN HUMAN HAIR AS ENVIRONMENTAL POLLUTION INDICATOR.: DETERMINATION OF SOME TRACE ELEMENTS IN HUMAN HAIR AS ENVIRONMENTAL POLLUTION INDICATOR.
...Show More Authors

Trace Elements (Cd, Pb, Cu, Zn, Ni) level were examined in hair of donors from industrial areas, cities and village, and in permanent contact with a polluted workplace environment in lattakia. Hair sample were analyzed for their contents of the trace elements by inductivity coupled plasma- mass spectrometer (ICP- MS). It was found that the contents of (Cd, Pb, Cu, Zn, Ni) in the hair were significantly higher in the industrial areas and cities, while in the village had the lower concentration of elements. Correlation coefficients between the levels of the elements in hair found in this study showed that hair is a good indicator of Environmental Pollution.

View Publication Preview PDF
Publication Date
Mon Feb 15 2021
Journal Name
Systematic Review In Pharmacy
Colorimetric Determination Of Sitagliptin As An Oxidation Derivative Of Ninhydrin
...Show More Authors

A sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and

... Show More
Preview PDF