Preferred Language
Articles
/
jih-1072
Comparison of Bayes' Estimators for the Exponential Reliability Function Under Different Prior Functions
...Show More Authors

 In this study, we derived the estimation for Reliability of the Exponential distribution based on the Bayesian approach. In the Bayesian approach, the parameter of the Exponential distribution is assumed to be random variable .We  derived  posterior distribution the parameter of the Exponential distribution under four types priors distributions for the scale parameter of the Exponential distribution is: Inverse Chi-square distribution, Inverted Gamma distribution, improper distribution, Non-informative distribution. And the estimators for Reliability is obtained using the two proposed loss function in this study which is based on the natural logarithm for Reliability function .We used simulation technique, to compare the resultant estimators in terms of their mean squared errors (MSE).Several cases assumed for the parameter of the exponential distribution for data generating of different samples sizes (small, medium, and large). The results were obtained by using simulation technique, Programs written using MATLAB-R2008a program were used. In general, we obtained a good estimations of  reliability of the Exponential distribution under the second proposed loss function according to the smallest values of mean squared errors (MSE) for all samples sizes (n) comparative to the estimated values for MSE under the first proposed loss function.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Using Genetic Algorithm to Estimate the Parameters of the Gumbel Distribution Function by Simulation
...Show More Authors

In this research, the focus was on estimating the parameters on (min- Gumbel distribution), using the maximum likelihood method and the Bayes method. The genetic algorithmmethod was employed in estimating the parameters of the maximum likelihood method as well as  the Bayes method. The comparison was made using the mean error squares (MSE), where the best  estimator  is the one who has the least mean squared error. It was noted that the best estimator was (BLG_GE).

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 14 2022
Journal Name
Journal Of Educational And Psychological Researches
Comparison between Rush Model Parameters to Completed and Lost Data by Different Methods of Processing Missing Data
...Show More Authors

The current study aims to compare between the assessments of the Rush model’s parameters to the missing and completed data in various ways of processing the missing data. To achieve the aim of the present study, the researcher followed the following steps: preparing Philip Carter test for the spatial capacity which consists of (20) items on a group of (250) sixth scientific stage students in the directorates of Baghdad Education at Al–Rusafa (1st, 2nd and 3rd) for the academic year (2018-2019). Then, the researcher relied on a single-parameter model to analyze the data. The researcher used Bilog-mg3 model to check the hypotheses, data and match them with the model. In addition

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 29 2018
Journal Name
Biomedical And Pharmacology Journal
Comparison of Some Mechanical and Physical Properties of three Types of Impression Materials with Different Dental Implant Angulations
...Show More Authors

Choosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sat Sep 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Travel Time Prediction Models and Reliability Indices for Palestine Urban Road in Baghdad City
...Show More Authors

Abstract

     Travel Time estimation and reliability measurement is an important issues for improving operation efficiency and safety of traffic roads networks. The aim of this research is the estimation of total travel time and distribution analysis for three selected links in Palestine Arterial Street in Baghdad city. Buffer time index results in worse reliability conditions. Link (2) from Bab Al Mutham intersection to Al-Sakara intersection produced a buffer index of about 36%  and 26 % for Link (1) Al-Mawall intersection to Bab Al- Mutham intersection and finally for link (3) which presented a 24% buffer index. These illustrated that the reliability get worst for link

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Sat Dec 01 2012
Journal Name
2012 Ieee-embs Conference On Biomedical Engineering And Sciences
Compatibility of mother wavelet functions with the electroencephalographic signal
...Show More Authors

View Publication
Scopus (23)
Crossref (18)
Scopus Crossref
Publication Date
Thu Oct 15 2015
Journal Name
Al Mustansyriah Journal Of Science
Comparison between (ARIMA) and (ANNs) models for estimating the relative humidity for Baghdad city
...Show More Authors

The aim of the research is to study the comparison between (ARIMA) Auto Regressive Integrated Moving Average and(ANNs) Artificial Neural Networks models and to select the best one for prediction the monthly relative humidity values depending upon the standard errors between estimated and observe values . It has been noted that both can be used for estimation and the best on among is (ANNs) as the values (MAE,RMSE, R2) is )0.036816,0.0466,0.91) respectively for the best formula for model (ARIMA) (6,0,2)(6,0,1) whereas the values of estimates relative to model (ANNs) for the best formula (5,5,1) is (0.0109, 0.0139 ,0.991) respectively. so that model (ANNs) is superior than (ARIMA) in a such evaluation.

Publication Date
Sun Apr 03 2005
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Low level treadmill testing of 50 patients with acute myocardial infarction prior to discharge from hospital
...Show More Authors

Objectives: (I) to describe the hemodynamic and electrocardiograph (ECG) responses in patients with acute myocardial infraction (AMI) to a low level treadmill test (2) to assess the safety of low-level treadmill testing after AMI (3) to determine if information gained from the test can be used for discharge planning.
Methods: 50 consecutive patients with AMI were subjected for symptoms limited treadmill testing in the CCU of University Teaching Hospital Iraqi medical College, their age range was from 30-70 with mean age of 55 years. Blood pressure, heart rate, and ECG during a low level treadmill test studied 6 days after AML They were divided into two groups, group I those who could finish the test and group 2 those who couldn't fini

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 30 2022
Journal Name
Iraqi Journal Of Science
Some Applications of Quasi-Subordination for Bi-Univalent Functions Using Jackson’s Convolution Operator
...Show More Authors

     In this paper, subclasses of  the function class  ∑  of analytic and bi-univalent functions associated with operator  L_q^(k,  λ)  are introduced and defined in the open unit disk △ by applying quasi-subordination. We obtain some results about the corresponding bound estimations of the coefficients  a_(2 )  and a_(3 ).

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Sep 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study on Carbon Steel Corrosion and its Inhibition Using Sodium Benzoate Under Different Operating Conditions
...Show More Authors

Corrosion experiments were carried out to investigate the effect of several operating parameters on the corrosion rate and corrosion potential of carbon steel in turbulent flow conditions in the absence and presence of sodium benzoate inhibitor using electrochemical polarization technique. These parameters were rotational velocity (0 - 1.57 m/s), temperature (30oC – 50oC), and time. The effect of these parameters on the corrosion rate and inhibition efficiency were investigated and discussed. It was found that the corrosion rate represented by limiting current increases considerably with increasing velocity and temperature and that it decreased with time due to the formation of corrosion product layer. The corrosion potential shifted t

... Show More
View Publication Preview PDF