Preferred Language
Articles
/
jih-1056
Studying Hueckel Edge Detector Using Binary Step Edge Image

Hueckel edge detector study using binary step edge image is presented. The standard algorithm that Hueckel presented, in his paper without any alteration is adopted. This paper studies a fully analysis for the algorithm efficiency, time consuming and the expected results with slide window size and edge direction. An analysis for its behavior with the changing of the slide window size (disk size) is presented. The best result is acquired when the window size equals to four pixel.  

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 30 2018
Journal Name
Iraqi Journal Of Science
Improve the Spatial Resolution of Multispectral satellite Image using Different Image Sharpening Techniques

The process of combining the significant information from a series of images into a single image called image sharpening or image fusing, where the resultant fused image will be having more spatial and spectral information than any of the input images. in this research two images of the same place in different spatial resolution have been used the first one was panchromatic and the second image was multispectral with spatial resolution 0.5m and 2 m respectively. These images were captured by world view-2 sensor. This research resent four pan sharpening methods like (HSV, Brovey (color normalizes) , Gram shmidt and PCA)these methods were used to combine the adopted images to get multispectral image

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Measurement of Natural Radioactivity in different cigarettes samples by using (HPGe) detector
Abstract<p>Twelve samples of cigarettes have been collected from local markets of different types and origins by using (HPGe) detector, and measurement of the specific activity for series U<sup>238</sup> and series Th<sup>232</sup> in addition to K<sup>40</sup> in order to estimate the health risk of cigarettes their by smokers, the results shown that highest specific activity value were be (12. 8±6. 3 Bq/kg, 8. 41±5. 8 Bq/kg, 125. 16±58. 3 Bq/kg), respectively, in the sample (MAC) MacBeth type cigarettes in Brazilian origin, this paper reports data such as (specific activity of K<sup>40</sup>, series U<sup>238</sup>, series Th<sup>232</sup></p> ... Show More
Crossref
View Publication
Publication Date
Mon Apr 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement of Radioactivity in Some Commercial Porcelain Samples by Using HPGe Detector

     Estimations of specific activity concentrations in eight commercial porcelain tiles made in different countries were performed by the use of HPGe detector. We have found that the highest specific activity concentrations for 238U, 40K were equal to (21.120 Bq/kg) and (283.862 Bq/kg) respectively, Iranian origin, while the highest specific activity concentration for 232Th was found to be equal to (29.292 Bq/kg), Iraqi origin; all of which were less than their corresponding recommended values given by (UNSCEAR, 2000). The radiation hazard indices [IÉ£ , Hin ,Hex , Raeq ,DÆ” , (AEDE) in and (AEDE) out] w

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Radon Concentration Measurement in Ainkawa Region Using Solid State Nuclear Track Detector

Radon is the air contaminant radioactive gas which people exposed to, is a reason for lung damages and lung cancer. The areas that are subject to high radon levels are found by radon concentration measurement. The radon activity concentration, annual effective dose, and potential alpha energy concentration (PAEC), were measured in houses of Ainkawa region using CR-39 solid state nuclear track detectors SSNTDs with the sealed-can technique. In the present paper the estimated values for radon activity concentration are in the range 55.99-112.8 Bq/m3 with 84.30 Bq/m3 as a mean value, the range of annual effective dose are 1.411-2.872 mSv/y, with mean value 2.124 mSv/y, and the potential alpha energy c

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Determination the concentration of radon in human urine using LR-115 detector

In the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.

Crossref
View Publication Preview PDF
Publication Date
Sat Dec 31 2022
Journal Name
Wasit Journal Of Computer And Mathematics Science
An Improved Method for Hiding Text in Image Using Header Image

The necessities of steganography methods for hiding secret message into images have been ascend. Thereby, this study is to generate a practical steganography procedure to hide text into image. This operation allows the user to provide the system with both text and cover image, and to find a resulting image that comprises the hidden text inside. The suggested technique is to hide a text inside the header formats of a digital image. Least Significant Bit (LSB) method to hide the message or text, in order to keep the features and characteristics of the original image are used. A new method is applied via using the whole image (header formats) to hide the image. From the experimental results, suggested technique that gives a higher embe

... Show More
Crossref
View Publication
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Comparison of Various Gradient Types for Biological Image with Morphological Operations

Biological image edge detection preserving the important structural properties in an image. Detecting accurate edges are very important for analyzing the basic properties associated with a biological image. Gradient operator plays very important role in edge detection. In this paper the images had been using are color biological images taken from microbiology laboratory at the biological department college of science Al-MustansiriyhUniversity and the effect of gradient operation have applied on around 10 different biological color images but view only two. In our proposed approach comparative of various gradient of biological image include (gradient of image, gradient of image using first order derivative edge detection (Soble,Prewitt,Ro

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Change detection of remotely sensed image using NDVI subtractive and classification methods.

Change detection is a technology ascertaining the changes of
specific features within a certain time Interval. The use of remotely
sensed image to detect changes in land use and land cover is widely
preferred over other conventional survey techniques because this
method is very efficient for assessing the change or degrading trends
of a region. In this research two remotely sensed image of Baghdad
city gathered by landsat -7and landsat -8 ETM+ for two time period
2000 and 2014 have been used to detect the most important changes.
Registration and rectification the two original images are the first
preprocessing steps was applied in this paper. Change detection using
NDVI subtractive has been computed, subtrac

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Development Binary Search Algorithm

There are many methods of searching large amount of data to find one particular piece of information. Such as find name of person in record of mobile. Certain methods of organizing data make the search process more efficient the objective of these methods is to find the element with least cost (least time). Binary search algorithm is faster than sequential and other commonly used search algorithms. This research develops binary search algorithm by using new structure called Triple, structure in this structure data are represented as triple. It consists of three locations (1-Top, 2-Left, and 3-Right) Binary search algorithm divide the search interval in half, this process makes the maximum number of comparisons (Average case com

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Binary Mixture of Estradiol and Progesterone Using Different Spectrophotometric Methods

Four rapid, accurate and very simple derivative spectrophotometric techniques were developed for the quantitative determination of binary mixtures of estradiol (E2) and progesterone (PRG) formulated as a capsule. Method I is the first derivative zero-crossing technique, derivative amplitudes were detected at the zero-crossing wavelength of 239.27 and 292.51 nm for the quantification of estradiol and 249.19 nm for Progesterone. Method II is ratio subtraction, progesterone was determined at λmax 240 nm after subtraction of interference exerted by estradiol. Method III is modified amplitude subtraction, which was established using derivative spectroscopy and mathematical manipulations. Method IIII is the absorbance ratio technique, absorba

... Show More
Crossref
View Publication Preview PDF