Preferred Language
Articles
/
jih-1029
The Corrosion Behavior of Different Gauges of Stainless Steel Wire Use in Removable Partial Denture and Orthodontics Appliances
...Show More Authors

  Wires are commonly used for the construction of orthodontic appliances and occasionally as wrought clasps and rests on partial dentures.           The corrosion resistance is the most important properties of dental alloy. Corrosion process reported to cause a numerous adverse effects on both living tissue and restoration .The conditions in the mouth are very suitable for the occurrence of corrosion. The main objective of this study was to evaluate the corrosion behavior of different gauges of stainless steel wire in artificial saliva .Four gauges of dental stainless steel wire used in orthodontic and removable partial denture were used in this study 0.6mm.,0.7mm.,0 .8mm.&1.0mm.).The specimens were divided according to gauge in  to four groups(A,B,C,&D ) ,ten specimens in each group .Each wire was cut by using wire cutter to get wire with (1cm) in length .Artificial saliva of Fusayama Meyer type was used as the testing solution .Sensitive electronic balance was used to weight the sample before immersion in solution and recording the results.This this represents the first weight(W1).Each specimen was put inside a test tube , and held using dental floss in a way that the specimen was fully immersed in the solution from all sides . The specimens then were put inside an incubator ,which was adjusted at 37±2 and left for 14 days .At the end of immersion period ; the specimens were removed from the solution and then allowed to dry and were balanced then the results were recorded .This represents the second weight (W2) .After obtaining the (W1)&(W2) the corrosion rate was calculated .        The results before and after immersion showed that the 0.6 mm.& 0.7mm stainless steel wire gave the highest and more corrosion resistance value than 0.8mm&1.0mm.stainless steel wire .      The result showed there is a statistical significance between (W1&W2) of 0.8mm stainless steel wire and highly significant between (W1&W2) of 1.0mm. stainless steel wire .     The comparison of the results after calculating results in corrosion rate formula showed that the 1.0mm stainless steel wire more corrosion resistance followed by 0.8mm wire ,from 0.6mm& 0.7 mm wire .
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
Impact of non-current assets impairment reporting on certain financial indicators application on Al-Mansour Pharmaceuticals- a private corporation
...Show More Authors

   This research deals with the financial reporting for non-current assets impairment from the viewpoint of international accounting standards, particularly IAS 36 "Impairment of non-current assets." The research problems focus on the presence of internal and external indicators on impairment of non-current assets in many of companies listed in Iraqi stock exchange. So it is required to apply IAS 36 to reporting for the impairment loss of assets since this impairment impact certain financial indicators. These indicators help users in their decision-making and forecasting future financial situation and the ability of the company to achieve future profits or maintain current profits. The research aims to shedding lig

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 21 2014
Journal Name
International Journal Of Antennas And Propagation
Development of a Compact Wide-Slot Antenna for Early Stage Breast Cancer Detection Featuring Circular Array Full-View Geometry
...Show More Authors

A novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.

Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Detection of Methamphetamine using Nanobentonite as a Novel Solid Phase Extraction Column Matrix Assisted with Gas Chromatography- Mass Spectroscopy
...Show More Authors

          This study was done to evaluate a new technique to determine the presence of methamphetamine in the hair using nano bentonite-based adsorbent as the filler of extraction column. The state of the art of this study was based on the presence of silica in the nano bentonite that was assumed can interact with methamphetamine. The hair used was treated using methanol to extract the presence of methamphetamine, then it was continued by sonicating the hair sample. Qualitative analysis using Marquish reagent was performed to confirm the presence of methamphetamine in the isolate.The hair sample that has been taken in a different period confirmed that this current developing method can be used to analyzed methamphetamine. This m

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Feb 06 2020
Journal Name
Scientific Reports
Waste foundry sand/MgFe-layered double hydroxides composite material for efficient removal of Congo red dye from aqueous solution
...Show More Authors
Abstract<p>We aimed to obtain magnesium/iron (Mg/Fe)-layered double hydroxides (LDHs) nanoparticles-immobilized on waste foundry sand-a byproduct of the metal casting industry. XRD and FT-IR tests were applied to characterize the prepared sorbent. The results revealed that a new peak reflected LDHs nanoparticles. In addition, SEM-EDS mapping confirmed that the coating process was appropriate. Sorption tests for the interaction of this sorbent with an aqueous solution contaminated with Congo red dye revealed the efficacy of this material where the maximum adsorption capacity reached approximately 9127.08 mg/g. The pseudo-first-order and pseudo-second-order kinetic models helped to describe the sorption measure</p> ... Show More
Scopus (172)
Crossref (110)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Measurement: Sensors
Dynamic monitoring of saturated stiff clay soil foundation structure by falling weight deflectometer system under impact loads sensors effect
...Show More Authors

Experiments research is done to determine how saturated stiff clayey soil responds to a single impulsive load. Models made of saturated, stiff clay were investigated. To supply the single pulse energy, various falling weights from various heights were tested using the falling weight deflectometer (FWD). Dynamic effects can range from the major failure of a sensitive sensor or system to the apparent destruction of structures. This study examines the response of saturated stiff clay soil to a single impulsive load (vertical displacement at the soil surface below and beside the bearing plates). Such reactions consist of displacements, velocities, and accelerations caused by the impact occurring at the surface depth induced by the impact loads

... Show More
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Kinetic studies of AST isoenzymes I,II,III,IV partially purified from patient,s urine with chroinc renal failure
...Show More Authors

In this research, the kinetic studies of four isoenzymes of Asprtate aminotransferase, which partially purified from the urine of chronic renal failure patients were carried out .The four isoenzymes were obeyed Michaelis-Menton's equation and the optimum concentration of their substrate (Aspartic acid) was (166.5x10-3) mole/liter,and their Km values were determined. Four isoenzymesI,II,III,IV have shown an optimum pH at 7.4.The four isoenzymes obeyed Arrhenius equation up to 37º C and their Ea and Q10 constants were determined .

View Publication Preview PDF
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Autogenous Onlay Graft with Compression Plate for Treatment of Persistent Humeral Shaft Aseptic Non-union with Failed Previous Surgery
...Show More Authors

BACKGROUND: The humeral shaft fractures have a good rate of union, despite this fact, still there is a significant rate of nonunion after nonoperative treatment and more often after operative treatment. AIM: The aim of the study is to evaluate the autogenous onlay graft with compression plate for treatment of persistent humeral shaft non-union with failed previous surgery both radiological and functional outcome. MATERIALS AND METHODS: A prospective study on twenty patients having persistent aseptic non-union age between 20 and 60 years old, after failed surgical treatment of fractures humeral shaft in Al-Zahra teaching and Al-Kindy teaching hospitals, while infected nonunion, diabetes mellitus, secondary metastasis, smoking, a

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Zn(II) Removal from Wastewater by Electrocoagulation/Flotation Method using New Configuration of a Split-Plate Airlift Electrochemical Reactor
...Show More Authors

In this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Survey of Some Parasitic Worms on Three Fish Species from Euphrates River at Al- Haklania District, Al-Anbar Province
...Show More Authors

    In the present study, a total of 272 freshwater fishes belonging to three species namely: Cyprinus carpio, Barbus xanthopterus and Aspius vorax, were collected from Euphrates river at Al-Haklania distrct, Al-Anbar province  during the period from August 2008 till the end of July 2009, by using gill nets and cast nets.       Fishes were survyed for intestinal parasitic worms. The investigation revealed the infectation of these fishes with four parasitic species: the digenetic trematode  Aspidogaster limacoides from the intestine of C. carpio, B. xanthopterus and A. vorax, larval nematode Contracaecum spp. from the body cavity of C. carpio and the external surface of intestine of B

... Show More
View Publication Preview PDF
Publication Date
Mon May 27 2019
Journal Name
Al-academy
A Hypothesis of Architectural Environment Exercise for Actor Training (Continuous exercise space workshop – A model): هيثم عبد الرزاق علي
...Show More Authors

The peculiarity of the theater does not lie in its dramatic content because many literary genres and other artistic styles share with it in this content. The peculiarity of the theater lies in contemplating the drama through what is architectural, and this architectural axis is what distinguishes its character. It is a spatial poetry which is composed by the laws of physics and chemistry, (Weight, height, distance, rhythm, gravity, impulses and chemical excretions). i.e., what cannot be expressed in words. This is a game of space to exchange and organize energy and communicate in space by the living body, which contains the possibilities of the living drawing in space: in the time and place. This research deals with the importance of the

... Show More
View Publication Preview PDF
Crossref