Preferred Language
Articles
/
jih-1029
The Corrosion Behavior of Different Gauges of Stainless Steel Wire Use in Removable Partial Denture and Orthodontics Appliances
...Show More Authors

  Wires are commonly used for the construction of orthodontic appliances and occasionally as wrought clasps and rests on partial dentures.           The corrosion resistance is the most important properties of dental alloy. Corrosion process reported to cause a numerous adverse effects on both living tissue and restoration .The conditions in the mouth are very suitable for the occurrence of corrosion. The main objective of this study was to evaluate the corrosion behavior of different gauges of stainless steel wire in artificial saliva .Four gauges of dental stainless steel wire used in orthodontic and removable partial denture were used in this study 0.6mm.,0.7mm.,0 .8mm.&1.0mm.).The specimens were divided according to gauge in  to four groups(A,B,C,&D ) ,ten specimens in each group .Each wire was cut by using wire cutter to get wire with (1cm) in length .Artificial saliva of Fusayama Meyer type was used as the testing solution .Sensitive electronic balance was used to weight the sample before immersion in solution and recording the results.This this represents the first weight(W1).Each specimen was put inside a test tube , and held using dental floss in a way that the specimen was fully immersed in the solution from all sides . The specimens then were put inside an incubator ,which was adjusted at 37±2 and left for 14 days .At the end of immersion period ; the specimens were removed from the solution and then allowed to dry and were balanced then the results were recorded .This represents the second weight (W2) .After obtaining the (W1)&(W2) the corrosion rate was calculated .        The results before and after immersion showed that the 0.6 mm.& 0.7mm stainless steel wire gave the highest and more corrosion resistance value than 0.8mm&1.0mm.stainless steel wire .      The result showed there is a statistical significance between (W1&W2) of 0.8mm stainless steel wire and highly significant between (W1&W2) of 1.0mm. stainless steel wire .     The comparison of the results after calculating results in corrosion rate formula showed that the 1.0mm stainless steel wire more corrosion resistance followed by 0.8mm wire ,from 0.6mm& 0.7 mm wire .
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 30 2024
Journal Name
Tikrit Journal For Dental Sciences
Aligning Archwires in Orthodontics: Exploring the Past, Present, and Future - A Comprehensive Narrative Review
...Show More Authors

Orthodontic wires facilitate the required dental adjustments in the context of orthodontic therapy. The archwire has played a crucial role in orthodontic treatment, and the increasing emphasis on aesthetic preferences from patients, as well as the development of composite and ceramic brackets, have prompted investigations into aesthetic archwires that complement these brackets. Orthodontic wires are produced using a diverse range of materials. The utilisation of all available wire types can improve patient comfort, decrease chairside time, and shorten the overall duration of treatment. The individual clinician must possess comprehensive knowledge and comprehension of the various requirements and alternatives throughout the therapeut

... Show More
View Publication
Crossref
Publication Date
Sat Apr 15 2023
Journal Name
Journal Of Mechanical Engineering
Corrosion Resistance Enhancement for Low Carbon Steel by Gas Phase Coating
...Show More Authors

Corrosion Resistance Enhancement for low carbon steel is very important to extend its life service, the coating process is one of the methods which can using to achieve this, and it's the most important in surface treatments to improve the properties of metals and alloys surfaces such as corrosion resistance. In this work, low carbon steel was nitrided and coated with nano zinc using gas phase coating technical, to enhance the resistance of corrosion. The process included adding two layers. The first, a nitride layer, was added by precipitating nitrogen (N) gas, and the second, a zinc (Zn) layer, was added by precipitating Zn. The process of precipitating was carried out at different periods (5, 10, and 15 minutes). Scan electron mi

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Studying the Effect of Different Separating Medium on the Roughness of the tissue surface of Acrylic Denture Base (In Vitro Study)
...Show More Authors

Objective: In order to evaluate the effect of different typed of Separating Medium on the roughness of the fitted
tissue surface of acrylic denture base.
Methodology: Chosen three types of separating medium (Group A Tin foil), (Group B Detery Isolant),(Group C
Cold Mould Seal),used 30 samples of hot cure acrylic resin ,10 samples for each group, after complete curing of
these samples , Profilometer device was used to measure the surface roughness of each sample in all groups.
Results: Using One Way ANOVA Test and LSD test, the results were highly significant in differences among all
groups. Although (Group A) showing lest roughness, (Group B) showing a satisfactory result of roughness, While
(Group C) Showing the hig

... Show More
View Publication Preview PDF
Publication Date
Mon May 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Use of Partial Purified Lipase From local Chicken kidney for Improvement the Flavor of Butter Fat
...Show More Authors

    Lipase was extracted by Sodium acetate buffer (pH=6; 0.05M) Containing 0.1M NaCl. Enzyme content of crude extract was concentrated by gradual addition of ammonium sulfate at 30-60% saturation. The dialyzed extract was purified on ion-exchange chromatography through DEAE–Cellulose and gel-filtration chromatography through sephacryl S-200 column. The specific activity, enzyme yield and fold purification were 54.06 unit/mg, 42.6% and 10.88 respectively. The molecular weight of the Lipase was 43.651 KDa as determined by gel-filtration chromatography through sephacryl S-200 column. Partial purified lipase used for the improvement of the flavor of butter fat after 12 hours for storage.

View Publication Preview PDF
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Study the effect of adding TiO2 nano-powder on some surface properties of TiO2 thin film prepared on stainless steel substrate
...Show More Authors

In this research TiO2 nano-powder was prepared by a spray pyrolysis technique and then adds to the TiO2 powder with particle size (0.523 μm) in ratio (0, 5, 10, 15 at %) atomic percentage, and then deposition of the mixture on the stainless steel 316 L substrate in order to use in medical and industrial applications.
Structure properties including x-ray diffraction (XRD) and scanning electron microscope (SEM0, also some of mechanical properties and the effect of thermal annealing in different temperature have been studied. The results show that the particle size of a prepared nano-powder was 50 up to 75 nm from SEM, and the crystal structure of the powders (original and nano powder) was rutile with tetragonal cell. An improvement in

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Surfaces And Interfaces
Corrosion performance of electrospinning nanofiber ZnO-NiO-CuO/polycaprolactone coated on mild steel in acid solution
...Show More Authors

View Publication
Scopus (34)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Inhibition Of Low Carbon Steel In Washing Water Of Crude Oil Solution In The Presence Of Folic Acid
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range (30–70)°C .The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature. Folic acid had on inhibiting effect on the corrosion of low carbon steel in washing water at a concentration (5× 10-4-- 5× 10-3 ) mol/dm3 over the temperature range (30–70)°C. Values of the protection efficiency were calculated from the corrosion current density .From the general results for this study, it can be seen that thermodynamic and kinetic function were also calculated (?G, ?S, ?H and Ea )

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Orthodontic Science
Keeping the teeth in line: Exploring the necessity of bonded retainers in orthodontics: A narrative review
...Show More Authors

In most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid post-treatment changes. The bonded fixed retainer is characterized by its clinical effectiveness, patient acceptance, and lack of patient complaints as compared with a removable retainer. An electronic database (such as PubMed, PubMed Central, Web of Science, Science Direct, Cochrane Library, Scopus, and ResearchGate) has been collected using specific keywords. Of the 152 articles, only randomized clinical trials that investigated different types of fixed retainers or compared fixed with removable retainers were illustrated in tables and included in this review. The

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jun 07 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength between thermosens as relining material and different denture base materials
...Show More Authors

Background: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strength at the relining-denture base interface is most important for denture durability.The aim of present study was to evaluate the shear bond strength between the thermosens as relining material and different denture base materials that bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dental clinic. Material and method: Sixty samples were prepared and divided into three main groups according to the type of denture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B) referred to the high impact acrylic samples which con

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2025
Journal Name
Advanced Journal Of Chemistry, Section A
Synthesis and Characterization of Heterocyclic Derivatives to Evaluate their Efficiency as Corrosion Inhibitors for Carbon Steel in Saline Medium
...Show More Authors

This work includes preparation of Az, Qz, and Tz derivatives from the reaction of Schiff base (Sb) derivative with anthranilic acid, chloroacetyl chloride, and sodium azide, as well as, the characterization via FT-IR, 1H-NMR, and 13CNMR. The anticorrosion inhibition of these compounds was studied and the measurements of carbon steel (CS) corrosion in sodium chloride solution 3.5% (blank) and inhibitor in solutions were calculated at a temperature range of 293-323 K by the technique of electrochemical polarization. In addition, some thermodynamic and kinetic activation parameters for inhibitor and blank solutions (Ea⋇, ΔH⋇, ΔS⋇, and ΔG⋇) were determined. The results showed high inhibition efficacy for all the prepared compounds,

... Show More
View Publication Preview PDF
Scopus (1)
Scopus