Preferred Language
Articles
/
jhiG3ZYBVTCNdQwCkofZ
Electrochemical Determination of Tetracycline at SPCE modified with Nanocomposite
...Show More Authors

An electrochemical sensor based on manganese dioxide nanorodMnO2and Graphene oxide (GO) functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (FGO)/MnO2Nanocompositewas developed for voltammetric determination of Tetracycline (TET).The working electrode WE of SPCE was modified bya drop casting method. X-ray powder diffractometer (XRD), scanning electron microscopy (SEM) and FT-IR were employed to characterize the synthesized FGO/MnO2. The determination of TET at the modified electrode was studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in the phosphate buffer solution (PBS).TET show sharp increase in the oxidation peaks in the pH 2.Voltammetric characteristics of TET (Epa, Ipa) were estimated. From effect of scan rate, the average surface coverage (Γ) of TET on the surface of SPCE modified with FGO/MnO2 nanocomposite, the electron transfer coefficient and electron transfer constant rate ket was obtained as 10.56×1014 molecule cm-2, 0.5, and 10.41 cm.s-1respectively. Under the optimal conditions, the peak current shows linear relationship with concentration of Tetracycline (TET) ranges 1–9 μM with the detection limit of 0.2μ M. The modified SPCE was successfully used to detect TET

Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Study the Oxidative Stress, Some Biochemical and Hematological Parameters in patients with agout at AL-Ramadi city
...Show More Authors

This study aims to study the effect of gout disease on complete blood picture and biochemical parameters and some non-enzymatic antioxidants, some tracing elements and lipid peroxidation ,in outpatients with gout disease at Al-Ramadi Teaching-Hospital ,Al-Razi Hospital and the study duration from Octo.2013-to May 2014.(50) blood samples were collected from patients with age groups (30-80 years) from both sexes (28 males,22 females),a (30) blood samples (15 males,15 females) were collected from normal individuals as a control group with age groups (27-75 years). Hematological measurement showed no significant differences in size compressed blood cells, the percentages in ( 45.15 +4.99 and 46.87+6.30) % in patient and control groups respect

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Determination the concentration of insulin-like growth factor-I (IGF-I) in saliva of acromegalic patients, and comparison it with the levels of serum IGF-I.
...Show More Authors

Acromegaly is ametabolic disorder characterized by an acquired progressive somatic disfigurement, mainly involving the face, extremities and many other organs, that are associated with systemic manifestations, caused by excessive secretion of growth hormone and a resultant persistent elevation of insulin-like growth factor-I concentrations. In more than 90% of cases originates from a monoclonal benign pituitary adenoma. Aim of this study to assess the level of insulin-like growth factor-I (IGF-I) in saliva of acromegalic patients, and to compare it with the basal levels of serum IGF-I. Sixty specimens of serum and saliva collected from two groups of subjects (forty acromegalic patients and twenty healthy persons). The specimens were

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric method for the determination of Captopril in pharmaceutical formulations
...Show More Authors

A simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
Exploiting the diazotization reaction of 4- minoacetophenone for Methyldopa determination.
...Show More Authors

Based on the diazotization reaction of 4-aminoacetophenone with sodium nitrite in acid medium to form diazonium salt, which was coupled with Methyldopa to form a violet reddish soluble azo dye with maximum absorbance at 560 nm,a batch procedure had been developed for the estamination of Methyldopa. Under optimum experimental parameters affecting on the development and stability of the colored product, Beer´s law obeyed in the range (0.5-45) ?g.ml-1 with a correlation coefficient (0.9979).The proposed method was successfully applied to the determination of Methyldopa in either pure form and in commercial brands of pharmaceuticals, no interference was observed from common excipients in the formulations. The analytical results obtained by app

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Determination The Effect of ZnO on Iraqi Bentonite Surface Properties
...Show More Authors

Bentonite is widely used in industrial applications. The present study reports the effect of adding different weights of ZnO to the Iraqi bentonite, on surface area, pore volume and real density. These surface properties were evaluated for pure and modified bentonite. The modification was made by adding different ZnO weights such as; ( 0.5%, 1%, 5%, 10% ). The effect of heat exposing for all modified clay samples at 500 ?C have been also evaluated. The results show that the addition of 0.5% ZnO leads to increase the surface area percentage about 36%, increase pore volume percentage about 5.48% and increase the real density percentage about 27.116%. When the samples exposed to 500 ?C, their surface area and pore volumes have been decreased a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption
...Show More Authors

This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.

In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Partial Differential Equations In Applied Mathematics
Determination of time-dependent coefficient in time fractional heat equation
...Show More Authors

View Publication
Scopus (14)
Crossref (3)
Scopus Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Spectrofluorimetric method for the determination of glibenclamide in pharmaceutical formulations
...Show More Authors

A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
linear equivalence determination of key-stream sequence using Z-Transform
...Show More Authors

the research ptesents a proposed method to compare or determine the linear equivalence of the key-stream from linear or nonlinear key-stream

View Publication Preview PDF
Publication Date
Sat Jan 10 2026
Journal Name
Journal Of Engineering
Assessment of Equivalent Grain Diameter for Soil Specific Surface Determination
...Show More Authors

View Publication