Eprospective study undertaken between January 2007 and January 2011, 58 consecutive cases with compound tibial shaft fractures. All fractures were stabilized by external fixator device AO/ASIF type after failed the manipulation under anesthesia (MUA) to restore the osseous alignment. In 32 patients cancellous bone graft were used from the upper part of the tibia to enhance healing process, all these patients were followed for an average of 8–12 months. Our findings showed that stabilization of the fracture shaft tibia by external fixation with cancellous bone graft had significantly better result, than external fixation alone. We conclude that unilateral, uniplanar external fixation with early bone grafting from upper part of the tibia is considered the best method of management for unstable tibial shaft fracture in our community. The frame offered sufficient stability even in segmental fractures; application time is very short in the hands of the experienced surgeon. dynamization of the fixator must not be forgotten, and lastly we recommended that the external fixation is not only used as temporary form of immobilization but can be used as a definitive stabilizing procedure until consolidation of the fracture. It is safe, effective, cheap and available in almost all orthopedics units in Iraq.
Background: Orthodontic therapy often causes external root resorption. Serum vitamin D (VD) level is important for tooth mineralization and bone remodeling. This study aimed to test the impact of vitamin D (VD) supplements on bone and root remodelling in a vitamin D (VD) deficient rat model following orthodontic retention. Methods and Material: 30 male Wistar rats were divided into three groups: a control group of 10 rats and two experimental groups of 10 rats each with vitamin D deficiency (VDD) induced by a VD-free diet for 21 days. And a third group with VD supplementAll groups received orthodontic active treatment using a modified orthodontic appliance that applied 50 gm of force for 14 days to move the maxillary right first mol
... Show MoreThis research was designed to study the effect of water and alcoholic crude extracts of Calvatia craniiformis in vitro and in vivo On the other hand this study tested the toxic effect of both extracts in normal laboratory mice. The results showed that water and alcoholic extracts relatively have an acute toxic effect in mice in respect to LD50 (85 mg/kg, and 177mg/kg respectively). However the chronic toxicity of water extract at three different concentration (50, 75, 100 mg/kg) and alcoholic extract at concentrations of (100, 150, 200 mg/kg) was investigated in normal mice by (I.P) administration for 30 days alternatively and one drag in 48 hours . The results indicated significant effect (P ? 0.01) increasing in (MI) and (BI) of bone mar
... Show MoreThis Action research aimed at Assisting Students of Faculty of Educational Sciences at Al-Quds Open University to design computerized lessons using the Power Point software and according to ADDIE model. The study sample consisted of 40 students who were taking a course titled Technology of Education during the second semester of the 2014-2015 academic year and three academic instructors . To collect the required date , the researchers used focus group technique and structured interviews to get information from the 40 students and the three academic instructors involved in the course Technology of Education in QOU /Nablus Branch. In addition to these methods, a workshop with a guiding checklist was employed t
... Show MoreThis study aims to estimate the accuracy of digital elevation models (DEM) which are created with exploitation of open source Google Earth data and comparing with the widely available DEM datasets, Shuttle Radar Topography Mission (SRTM), version 3, and Advanced Spaceborne Thermal Emission and Reflection Radiometer Global Digital Elevation Model (ASTER GDEM), version 2. The GPS technique is used in this study to produce digital elevation raster with a high level of accuracy, as reference raster, compared to the DEM datasets. Baghdad University, Al Jadriya campus, is selected as a study area. Besides, 151 reference points were created within the study area to evaluate the results based on the values of RMS.Furthermore, th
... Show MoreThis paper presents a numerical simulation of the flow around elliptic groynes by using CFD software. The flow was simulated in a flume with 4m long, 0.4m wide, and 0.175m high with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow inlet with a constant the Groyne height of 10cm and a 1cm thickness, and the width of Groynes equals 7cm. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of 0.0057m3/sec. The CFD model showed a good ability to simulate the flow around Groynes with good accuracy. The results of CFD software showed that when using double elliptic Groy
... Show MoreThe dewatering arrangement is required in execution works and it needs more attention due to the additional vertical settlement produced on the adjacent pile foundations. Raft foundations are being increasingly utilized for construction in cases of subsoil conditions with a high water table. Also, soil displacements in adjacent un-braced deep open pit may be a reason for high damages to the close buildings and foundations systems. The aim of this study is to examine the behaviour of piled raft foundations considering different pile locations under the effect of line drain and stage drilling of nearby open foundation pit. The line drain was used as dewatering process through the soil i
For the design of a deep foundation, piles are presumed to transfer the axial and lateral loads into the ground. However, the effects of the combined loads are generally ignored in engineering practice since there are uncertainties to the precise definition of soil–pile interactions. Hence, for technical discussions of the soil–pile interactions due to dynamic loads, a three-dimensional finite element model was developed to evaluate the soil pile performance based on the 1 g shaking table test. The static loads consisted of 50% of the allowable vertical pile capacity and 50% of the allowable lateral pile capacity. The dynamic loads were taken from the recorded data of the Kobe e