Preferred Language
Articles
/
jeasiq-848
Comparison between some of linear classification models with practical application
...Show More Authors

Linear discriminant analysis and logistic regression are the most widely used in multivariate statistical methods for analysis of data with categorical outcome variables .Both of them are appropriate for the development of linear  classification models .linear discriminant analysis has been that the data of explanatory variables must be distributed multivariate normal distribution. While logistic regression no assumptions on the distribution of the explanatory data. Hence ,It is assumed that logistic regression is the more flexible and more robust method in case of violations of these assumptions.

In this paper we have been focus for the comparison between three forms for classification data belongs two groups when the response variable with tow categorise only.

The first form is the linear discriminant function ,The second is the probability form which it is derivative as alternative for the linear discriminant function while the third form is the probability function model. Of the logistic regression the comparison between these methods is based on measure of the probability  of misclassification .We show that the results of the  probability form  of the logistic regression has minimum probability of misclassification through the application on the data of two types of (leukemia).

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
PREPARATION OF ACTIVATED CARBONS FROM DATE STONES BY CHEMICAL ACTIVATION METHOD USING FeCl3 and ZnCl2 as ACTIVATING AGENTS
...Show More Authors

Date stones were used as precursor for the preparation of activated carbons by chemical
activation with ferric chloride and zinc chloride. The effects of operating conditions represented
by the activation time, activation temperature, and impregnation ratio on the yield and adsorption
capacity towards methylene blue (MB) of prepared activated carbon by ferric chloride activation
(FAC) and zinc chloride activation (ZAC) were studied. For FAC, an optimum conditions of 1.25
h activation time, 700 °C activation temperature, and 1.5 impregnation ratio gave 185.15 mg/g
MB uptake and 47.08 % yield, while for ZAC, 240.77 mg/g MB uptake and 40.46 % yield were
obtained at the optimum conditions of 1.25 h activation time, 500

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Thu Apr 12 2018
Journal Name
Lubricants
Importance of Emulsification in Calibrating Infrared Spectroscopes for Analyzing Water Contamination in Used or In-Service Engine Oil
...Show More Authors

View Publication
Scopus (15)
Crossref (12)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of Instruction Program on Pregnant Women’s Knowledge regarding Anemia at Primary Health Care Centers in Baquba City
...Show More Authors

Objective: to identify the effect of the Instruction program on the knowledge of pregnant women who suffering anemia.

Methodology: A quasi-experimental design was carried out with the application of pre- post test for the study and the control group. Purposive sample, consists of (60) pregnant women diagnosed with anemia attending four health care centers in Baquba city.

Result: The findings indicate that the level of hemoglobin is increasing post instructional program among women in the study group, in which (46.7%) of women are reveal a level of (8.1-9) g/dl that is less than normal pre instructional program and the level is increased to normal level post instructional

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Synthesis and Structural Determination of 6-O-prop-2-ynyl-1,2:3,4-di-O-Isopropylidene-α-D-Galactose
...Show More Authors

In this work, an important sugar alkynyl ether has been synthesized in two subsequent steps starting from commercially available D-galactose (3). This kind of compounds is highly significant in the synthesis of biologically active molecules such as 1,2,3-triazole and isoxazoles. In the first step, galactose (3) was reacted with acetone in the presence of anhydrous copper (II) sulfate to produce 1,2:3,4-di-O-isopropylidene-α-D-galactose (4) in good yield. The latter was reacted with excess of 3-bromoprop-1-yne in DMF in the presence of NaOH pellets to afford the target molecule 5 in a very good yield. The temperature of this step is crucial in determining the reaction yi

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Facies Analyses and Diagenetic features development of Albian - Aptian Succession in the Wset Qurna oil field, Southern Iraq
...Show More Authors

The Carbonate-clastic succession in this study is represented by the Shuaiba and Nahr Umr Formations deposited during the Albian - Aptian Sequence. The present study includes petrography, microfacies analyses, and studying reservoir characterizations for 5 boreholes within West Qurna oil field in the study area. According to the type of study succession (clastic – Carbonate) there are two types of facies analyses:-Carbonate facies analysis, which showed five major microfacies were recognized in the succession of the Shuaiba Formation, bioclastic mudstones to wackstone, Orbitolina wackestone to packstone, Miliolids wackestone, Peloidal wackestone to packstone and mudstone to wackestone identified as an open shelf toward the deep basin.

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
The DC electrical Conductivity of prepared pure polypyrrole and polypyrrole /graphene (PPY/GN) nanocomposite by in-situ polymerization
...Show More Authors

Abstract

 In this work, pure Polypyrrole (PPy) and Polypyrrole (PPy)/Graphene (GN) was synthesized by in-situ polymerization in different weight percentages (0.1, 0.3, 0.5, 1, 3 and 5 wt.% (g)) of GN nano particles using chemical oxidation method at room temperature. The FTIR, SEM and electrical properties were studies for the nano composites. The result show that when concentration of GN Nano particle increase, the electrical conductivity increased and the graphene sheets were merging to form a continuous area of the GN through the polypyrrole base material. The FTIR spectra shows that the characteristics absorption peaks of polypyrrole that is, 1546.80, 1463.87 and 3400.27 cm-1(stretching vibration in the pyrrol

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Relative intensity distribution in the rotational structure for B1Σ+- A1Π and B1Σ+- X1Σ+ electronic systems of BeO molecule
...Show More Authors

Theoretical spectroscopic study of  Beryllium Oxide has been carried out, Boltzmann distribution of P, Q and R branches in the range of (0<J<13) at temperature 4200K for (0-0) band for electronic transitions B1Σ+-A1Π and B1Σ-X1Σ. The Boltzmann distribution of these branches has a maximum values at equal J approximately while the values of relative population are different. For the B1Σ+- X1Σ+ transition the branch's lines extend towards lower wavenumber. This is because (Bv'-Bv") value is negative, i.e  Bv'< Bv" For B1Σ+-A1Π

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 04 2023
Journal Name
Environmental Progress &amp; Sustainable Energy
Removal of <scp>E133</scp> brilliant blue dye from artificial wastewater by electrocoagulation using cans waste as electrodes
...Show More Authors
Abstract<p>Solid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm<sup>2</sup>), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on </p> ... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Feb 19 2021
Journal Name
Annals Of Telecommunications
Challenges and limits of fractal and slot antennas for WLAN, LTE, ISM, and 5G communication: a review paper
...Show More Authors

Abstract Portable communication devices such as WLAN, WiMAX, LTE, ISM, and 5G utilize one or more of the triple bands at (2.32.7 GHz,3.4–3.6GHz,and5–6GHz)andsufferfromtheeffectofmultipathproblemsbecausetheyareusedinurbanregions.To date, no one has performed a review of the antennas used for these types of wireless communications. This study reviewed two types of microstrip antennas (slot and fractal) that have been reported by researchers (as a single element) using a survey that included the evaluation of several important specifications of the antennas in previous research, such as operating bandwidth, gain, efficiency, axial ratio bandwidth (ARBW), and size. The weaknesses in the design of all antennas were carefully identified to de

... Show More
View Publication
Scopus (12)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref