The impact of the auditor's personal judgment starts from the beginning of the audit process to the formation of the final opinion and the issuance of the report, and because of the possibility of bias in the auditor's judgment for various reasons that may relate to the auditor himself or the circumstances surrounding it, which requires assessing the current reality of the auditor's personal judgments In the local environment and determining their determinations. To clarify the concept and determinants of the auditor's personal judgments when implementing the audit work, prepare the report and determine the role of the international auditing standards in rationalizing the auditor's personal judgment when conducting his audit activity. Implementing the requirements of international auditing standards that require the exercise of personal judgment, which helps the auditor in rationalizing and limiting his personal provisions .But , there are some shortcomings that may be reflected in the auditor's judgment, including the auditor's reliance on his personal experience only in determining the relative importance of the component, as well as the auditor's greater reliance on the internal audit evidence, as well as the fact that the auditor does not use analytical procedures at the end of the process The audit is in the preparation stage of the report, which is a basic requirement of the audit standard 520, which is reflected in the personal judgments taken. The study concluded with a set of recommendations, the most important of which is the need to carry out training activities related to personal judgment and to raise awareness and confidence in it to enhance the expertise of the auditors and the auditor to collect more relevant internal and external information before taking personal judgment as well as guidelines and instructions to improve the ability to exercise personal judgment. With regard to carrying out analytical procedures near the end of the audit process, and relying more on external audit evidence.
In the present study, magnet silica-coated Ag2WO4/Ag2S nanocomposites (FOSOAWAS) were fabricated via a multistep method to address the drawbacks related to single photocatalysts (pure Ag2WO4 and pure Ag2S) and to clarify the significant influence of semiconductor heterojunction on the enhancement of visible-light-driven organic degradation. Different techniques were performed to investigate the elemental composition, morphology, magnetic and photoelectrochemical properties of the fabricated FOSOAWAS photocatalyst. The FOSOAWAS photocatalyst (1 g/L) exhibited excellent photodegradation efficiency (99.5%) against Congo red dye (CR = 20 ppm) after 140 min of visible-light illumination. This result confirmed the ability of the heterojunction be
... Show Moreفي هذا البحث تم تحضير المركبات المعدنية الجديدة لأيونات البلاتين (الرباعي) و الذهب (الثلاثي) مع ليكاند قاعدة مانخ جديد مشتق من السيبروفلوكساسين . تم استخدام المعقدات بعد ذلك كمصدر لتحضير جزيئات عن طريق ترسيب المعقدات على مسام دقائق السيليكا النانوية. Si/Au2O3 Si/PtO2 تم تشخيص الليكاند و معقداته
... Show MoreA specific, sensitive and new simple method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation of ion pair compound between methyldopa and potassium hexacyanoferrate in acidic medium to obtain a yellow precipitate complex using long distance chasing photometer (NAG-ADF-300-2). The linear range for calibration graph was 0.05-35 mmol/L for cell A and 0.05-25 mmol/L for cell B, and LOD 1.4292 µg /200 µL for both cells with correlation coefficient (r) 0.9981 for cell A and 0.9994 for cell B, RSD% was lower than 0.5 % for n=8 for. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbi
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show More