تقدير النموذج اللوجستي باستخدام اوزان بيز المتسلسل
The goal beyond this Research is to review methods that used to estimate Logistic distribution parameters. An exact estimators method which is the Moment method, compared with other approximate estimators obtained essentially from White approach such as: OLS, Ridge, and Adjusted Ridge as a suggested one to be applied with this distribution. The Results of all those methods are based on Simulation experiment, with different models and variety of sample sizes. The comparison had been made with respect to two criteria: Mean Square Error (MSE) and Mean Absolute Percentage Error (MAPE).
In this paper, the generalized inverted exponential distribution is considered as one of the most important distributions in studying failure times. A shape and scale parameters of the distribution have been estimated after removing the fuzziness that characterizes its data because they are triangular fuzzy numbers. To convert the fuzzy data to crisp data the researcher has used the centroid method. Hence the studied distribution has two parameters which show a difficulty in separating and estimating them directly of the MLE method. The Newton-Raphson method has been used.
... Show MoreIn the current study, haemoglobin analytes dissolved in a special buffer (KH2PO4(1M), K2HPO4(1M)) with pH of 7.4 were used to record absorption spectra measurements with a range of concentrations from (10-8 to 10-9) M and an absorption peak of 440nm using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) which is considered a simple, low cost, and robust setup. The principle work of this technique depends on the multiple reflections between the light source, which is represented by the Light Emitting Diode 3 W, and the detector, which is represented by the Avantes spectrophotomer. The optical cavity includes two high reflectivity ≥99% dielectric mirrors (dia
... Show MoreThere is confusion between the concept of honesty and credibility arguing that their meaning is the same. ‘Credibility; is derived from the truth which means evidence of honesty, while ‘honesty’ means not lying and matching reality. The study of credibility begins globally at the end of the fifties of the second millennium to see the decline and refrain from reading newspapers, while it was studied in the Arab world in 1987. Global studies find several meanings of the concept of ‘credibility’ such as accuracy, completeness, transfer facts, impartiality, balance, justice, objectivity, trust, honesty, respect the freedom of individuals and community, and taking into account the traditions and norms.
Credibility has two dimens
In this paper, we investigate the behavior of the bayes estimators, for the scale parameter of the Gompertz distribution under two different loss functions such as, the squared error loss function, the exponential loss function (proposed), based different double prior distributions represented as erlang with inverse levy prior, erlang with non-informative prior, inverse levy with non-informative prior and erlang with chi-square prior.
The simulation method was fulfilled to obtain the results, including the estimated values and the mean square error (MSE) for the scale parameter of the Gompertz distribution, for different cases for the scale parameter of the Gompertz distr
... Show MoreThis current study was built on creating four electrodes based on molecularly imprinted polymers (MIPs). As the template using Cefalexin (CFX), 1-vinyl imidazole (VIZ) and vinyl acetate (VA) as monomer, and N, N-methylene bis acrylamide (MBAA) as cross-linkers and benzoyl peroxide as the initiator, two MIPs were prepared. The same composition was used in non-impressed polymers (NIPs) preparation, but without the template (Cefalexin). For the membranes preparation, numerous plasticizers, such as tri-oly phosphate (TOP) and di-octyl phthalate (DOP), were used in the PVC matrix, slop, detection limit, lifetime, and linearity range of CFX-MIPs electrodes are characteristics &nb
... Show MoreIn this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media. The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w
... Show Moreيعود اهتمام العالم بالبيئة الى التدهور والتغيرات المستمرة جراء الاستغلال البشري الخاطئ لها من خلال رمي المخلفات وبأنواع مختلفة اذ ان البيئة المائية تتعرض يوميا الى الاف الاطنان من المخلفات المختلفة التي أدت الى تلوثها وتزداد هذه الملوثات يوما بعد يوم ومما يؤدي الى الاضرار في البيئة المائية ،و تعد الأنهار المصدر الأساسي للحياة الطبيعية ولكون نهر الفرات احد اهم المصادر المائية وتعتمد عليه العديد من الف
... Show MoreCladosporium sp. plays an important role in human health, it is one of the pathogenic fungi which cause allergy and asthma and most frequently isolated from airborne spores. In this study, a couple of universal PCR primers were designed to identify the pathogenic fungi Cladosporium sp. according to conserved region 5.8S, 18S and 28S subunit ribosomal RNA gene in Cladosporium species. In silico RFLP-PCR were used to identify twenty-four Cladosporium strains. The results showed that the universal primer has the specificity to amplify the conserved region in 24 species as a band in virtual agarose gel. They also showed that the RFLP method is able to identify three Cladosporium spe
... Show Moreفي هذا البحث حضر الكاربون المنشط ذو الحجم الحبيبي في المدى المايكروي والمدى النانوي من قشور الجوز واجريت عملية الكربنة باستخدام فرن المايكرويف ومن ثم استعمل محلول (%50) من حامض الفسفوريك مع المادة المكربنة وبأزمان مختلفة (2,4,8,16,24) ساعة لتحديد الزمن الأفضل لعملية التنشيط في هذا البحث ، وبعد ذلك اضيفت نسب وزنية مختلفة من مخلفات بولي بروبلين عند زمن (8) ساعة وكانت النسب 0.05):,1 0.1:,1 0.15:0.2 ,1: (1:0.25 ,1 للمضاف البوليمري ومس
... Show More