Preferred Language
Articles
/
jcois-1387
The attitude of Imam Ibn Jarir al-Tabari to the occurrence of unanimous and its convening by statement of the majority in light of his interpretation - Jami` al-Bayan on the interpretation of the verse of the Qur’an -‘‘Applied Models’’
...Show More Authors

t

 

The research deals with the statement of the importance of unanimous in Islamic Sharia in terms of being the third source of Islamic legislation after the Holy Qur’an and the Sunnah of the Prophet, and the extent of interest of the scholars of interpretation in it, and those who took great interest in mentioning what was agreed upon in every site that necessitated mentioning its issues within, or mentioning an event that has encountered an unanimous, and in various sciences, to extract and extrapolate Sharia rules when these rules are lost in the texts, because it is based on them and derived from them. Among these distinguished scholars is Muhammad bin Jarir al-Tabari. Besides, the research discusses interpretational applications for some meanings of Quran’ vocabulary, as well as the opinion of al-Tabari in some Fiqh rules that he was singled out for based on his disagreement with the majority of fundamentalists on a fundamental issue of unanimous issues, namely: Does unanimous convenes when the most diligent of the scholars state about a matter that needs their unanimous? Or is it not convened without the agreement of all of them without violating any of them? So, he went on to say: The unanimous is convened with the disagreement of one and two of scholars in face of the agreement of most of the agreed ones, because the majorities are scholars and interpreters. Thus, he adopts the unanimous of the majority, and, for him, those who have not reached the limit of the frequency have been considered neither as a disagreement issue nor breaking the unanimous, nor disagreeing with it. In this issue, the majority of the scholars said: The condition for convening the unanimous along with its occurrence is the agreement of all diligents without fear of any one of them, otherwise there will be no unanimous

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 12 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn: 1683 - 3597 , E-issn : 2521 - 3512)
A Pharmacoeconomics Study for Anticoagulants used for Hospitalized COVID-19 Patients in Al-Najaf Al-Ashraf city –Iraq(Conference Paper )#
...Show More Authors

Abstract Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through evidence-based pricing decisions. O

... Show More
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
The performance of MnO<sub>2</sub>/graphite electrode for TOC removal from wastewater by indirect electrochemical oxidation process
...Show More Authors

Electrochemical oxidation in the presence of sodium chloride used for removal of phenol and any other organic by products formed during the electrolysis by using MnO2/graphite electrode. The performance of the electrode was evaluated in terms fraction of phenol and the formed organic by products removed during the electrolysis process. The results showed that the electrochemical oxidation process was very effective in the removal of phenol and the other organics, where the removal percentage of phenol was 97.33%, and the final value of TOC was 6.985 ppm after 4 hours and by using a speed of rotation of the MnO2 electrode equal to 200 rpm.

View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Al-khwarizmi Engineering Journal
The Remediation of Congo Red-Contaminated Groundwater by using a Permeable Reactive Barrier Through Modified Waterworks Sludge MgAl-LDH
...Show More Authors

This investigation aims to explore the potential of waterworks sludge (WS), low-cost byproduct of water treatment processes, as a sorbent for removing Congo Red (CR) dyes. This will be achieved by precipitating nano-sized (MgAl-LDH)-layered double hydroxide onto the surface of the sludge. The efficiency of utilizing MgAl-LDH to modify waterworks sludge (MWS) for use in permeable reactive barrier technology was confirmed through analysis with Fourier transform infrared and X-ray diffraction. The isotherm model was employed to elucidate the adsorption mechanisms involved in the process. Furthermore, the COMSOL model was utilized to establish a continuous testing model for the analysis of contaminant transport under diverse conditions.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Surface Characterization of PEKK Modified by stron-tium –hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique
...Show More Authors

Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition. Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray

... Show More
Crossref (8)
Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Surface Characterization of PEKK Modified by stron-tium –hydroxyapatite coating as implant material Via the magnetron sputtering Deposition technique
...Show More Authors

Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition.

Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray dif

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (8)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Al-khwarizmi Engineering Journal
The Remediation of Congo Red-Contaminated Groundwater by using a Permeable Reactive Barrier Through Modified Waterworks Sludge MgAl-LDH
...Show More Authors

This investigation aims to explore the potential of waterworks sludge (WS), low-cost byproduct of water treatment processes, as a sorbent for removing Congo Red (CR) dyes. This will be achieved by precipitating nano-sized (MgAl-LDH)-layered double hydroxide onto the surface of the sludge. The efficiency of utilizing MgAl-LDH to modify waterworks sludge (MWS) for use in permeable reactive barrier technology was confirmed through analysis with Fourier transform infrared and X-ray diffraction. The isotherm model was employed to elucidate the adsorption mechanisms involved in the process. Furthermore, the COMSOL model was utilized to establish a continuous testing model for the analysis of contaminant transport under diverse conditions. A st

... Show More
View Publication
Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Journal Of Ecological Engineering
Enhancing the Removal of Methyl Orange Dye by Electrocoagulation System with Nickel Foam Electrode – Optimization with Surface Response Methodology
...Show More Authors

Azo dyes like methyl orange (MO) are very toxic components due to their recalcitrant properties which makes their removal from wastewater of textile industries a significant issue. The present study aimed to study their removal by utilizing aluminum and Ni foam (NiF) as anodes besides Fe foam electrodes as cathodes in an electrocoagulation (EC) system. Primary experiments were conducted using two Al anodes, two NiF anodes, or Al-NiF anodes to predict their advantages and drawbacks. It was concluded that the Al-NiF anodes were very effective in removing MO dye without long time of treatment or Ni leaching at in the case of adopting the Al-Al or NiF-NiF anodes, respectively. The structure and surface morphology of the NiF electrode were inves

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Evaluation of Three Important Electrode Arrays in Defining the Vertical and Horizontal Structures in 2D Imaging Surveys
...Show More Authors

Three important electrode arrays in 2D imaging surveys were tested in this study through synthetic model to determine which array is the most successful in defining the vertical and horizontal geological structures. These arrays are Wenner-Schlumberger, Wenner and Dipole - dipole. The numerical modeling was created through vertical fracture zone and three separate cavities surrounded by horizontal layers. The results showed that the Wenner-Schlumberger is the most suitable electrode array when both vertical and horizontal structures are present in the subsurface. It is the best in imaging the vertical and horizontal contacts and represented these structures more accurately than the Wenner and Dipole-dipole arrays.

View Publication Preview PDF
Publication Date
Tue Sep 28 2021
Journal Name
Journal Of Physical Education
The Contribution of Ball Launching and Ring Entrance Angle Variables in 3 points Jump Shot in Basketball
...Show More Authors

    The research aimed at identifying the values of ball launch and ring entrance angle and relations among them as well as identifying the contribution of ball launch and angle variables in 3 point jump in basketball. The researchers hypothesized statistical relation between ball launch and entrance angle. They used the descriptive method on (10) basketball players best known for their 3 point jump shot. Each player is given (10) attempts and only attempts with a larger entrance angle in recorded. The results showed that the height of ball launch players an integral role in decreasing entrance angle as well as ball launch angle did not correlate with the entrance angle. Finally, ball launch variables have no effect or contribution on ba

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref